Error code reference

Amana Dryer Error Codes

164 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
00Temperature display code indicating thermistor reads approximately 100°F in temperature…0EDoor is open (displayed during diagnostic mode when door is opened).1Thermistor short sensed10No wet clothes2Thermistor open sensed3Door circuit failure3 beepsThermistor or wiring harness is either short-circuited or open; dryer shuts off after a…4Possible motor transistor error8Stuck key81Lower Exhaust Probe Fault82Lower Axial Probe Fault83Lower Sail Switch Closed Fault84Lower Sail Switch Open Fault86Upper Exhaust Probe Fault87Upper Axial Probe Fault88Upper Sail Switch Closed Fault89Upper Sail Switch Open Fault90Upper Rotation Sensor Fault91Lower Rotation Sensor Fault92Gen 2 Card Reader Communication Fault.ACCUDryer motor control circuit error-the control cannot determine if the motor relay is…AFLow inlet air flow detected at installation.AIRFLOW FAULTLint chamber air pressure switch indicates insufficient airflow through the dryer…AXIAL PROBE FAULTProblem with the axial temperature sensor circuit.BURNER CONTROL FAULTGas return valve signal did not turn on before DSI purge time expired or turned on for…BURNER HIGH LIMIT FAULTIndicates the temperature disk in the burner has opened (tumbler hi-limit has tripped).BURNER IGNITION CONTROL FAULTNo signal to gas valve from Direct Spark Ignition (DSI) module during trial for ignition…BURNER PURGE FAULTGas return signal detected before the heat signal was sent out by the controller.CHECK CONTROL BOARD FUSE #2Main fuse (fuse 2) on the Phase 7 computer board has opened; controller will not allow a…CHK. LINT DRAWEROne or both lint drawers are not closed; lint drawer proximity switch circuit is open.CLEAN LINTLint drawer has not been opened within the programmed Lint Cleaning Frequency Setting…CNTRL VOLT OFF110 VAC control voltage has not been turned on via the master control relay.d1Dryer door sense error on control board or due to power line interference (cycles and…d12Motor sense error on control board or due to power line interference (cycles and customer…d13Blocked coin 2 or coin drop UI control circuit failure (coin recognition and customer…d16Control board not receiving communication from debit card reader in Enhanced (Generation…d4Dryer motor control circuit error (cycles and customer display disabled until diagnostic…d5Blocked coin 1 or coin drop UI control circuit failure (coin recognition and customer…d9Low voltage detected; less than 90 volts for 8 seconds AC.dCDoor circuit failuredc.1Blocked coin 1 or coin drop UI control circuit failure; coin recognition and customer…dc.2Voltage detected below 90 VAC for 8 seconds.dc.3Blocked coin 2 or coin drop UI control circuit failure; coin recognition and customer…dc.4Not receiving communications from installed debit card reader in Enhanced (Generation 2)…dc.5Dryer motor control circuit error; cycles and price display disabled until diagnostic…dc.6Exhaust thermistor open; temperature drops below 18°F (>50 kOhm) for 1 minute in Run…dc.7Exhaust thermistor shorted; temperature above 250°F (<500 Ohm) for 1 minute in Run mode…dc.8UI is not receiving communications from CCU; cycles and price display disabled while…dc.9CCU is not receiving communications from UI; cycles and price display disabled while…dc.AUI Microprocessor is not able to read or verify EEPROM; cycles and price display disabled…dc.bUI EEPROM memory is a CRC failure; cycles and price display disabled until diagnostic…DISCONNECTED WATER VALVES.A.F.EdoDoor opendonEDrying and cooling cycles complete, or dryer is in the anti-wrinkle cycle.doorDoor switch circuit is openDOOR OPENOne or more doors (load door, unload door, heat console access door, or burner doors) are…DRUM FAULTTumbler (basket) has stopped rotating; the rotational proximity sensor target has not…dSFLFault detected in the microprocessor temperature sensor circuit; buzzer will sound…EInvalid selection made on the electronic control display.E1Top Radiant Sensor fault countE2Top Burner Ignitor fault countE3User interface keyswitch or software mismatch between the control panel/touchpad assembly…E4Bottom Radiant Sensor fault countE5Bottom Burner Ignitor fault countE6Bottom Exhaust High LimitE7Coin 1 Bad Coin countE8Coin 2 Bad Coin CountE9Upper pocket forward rotation sensor fault count.EAUpper pocket reverse rotation sensor fault count.EBLower pocket forward rotation sensor fault count.ECLower pocket reverse rotation sensor fault count.EDS.A.F.E. DISABLEDEE PROM FAULT ###Error in memory location; the ### indicates the location of the fault.EXHAUST DSFLExhaust air temperature control sensor has detected a fault condition in the burner…EXHAUST HIGH LIMIT FAULTIndicates the temperature disk in the exhaust has opened.EXHAUST HIGH TEMP FAULTTemperature sensor input shows overheating with steady gradual increase to a known upper…EXHAUST PROBE FAULTProblem with the exhaust temperature sensor circuit.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted air flow condition existsF-50No voltage detected at the water valve relay (steam models only, only appears in…F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected on L2 (only appears in diagnostic test…F:50No voltage detected at the water valve relay (only appears in diagnostic test mode).F:72Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).F01Dryer motor control circuit error (cycles and price display disabled until diagnostic…F1Exhaust thermistor shorted-temperature above 250°F (<500Ω) for 1 minute in Run mode, or…F1E1No voltage detected at the heater relay, indicating a motor or heater failure or…F2CCU is not receiving communications from UI (cycles and price display disabled while…f2 e1Stuck button or user interface mismatch (keypad/user interface failure)F22Exhaust thermistor open, temperature drops below 18°F (>50 kΩ) for 1 minute in Run mode…F23Exhaust thermistor shorted, temperature above 250°F (<500 Ω) for 1 minute in Run mode, or…F3Blocked coin 1 or coin drop UI control circuit failure (coin recognition and customer…F3E1Exhaust thermistor is open (>50k ohms, below 18°F/-8°C) or shorted (<500 ohms, above…F3E2Moisture sensor strip is open or shorted (only appears in service diagnostic mode).F3E3Inlet thermistor is open (>245k ohms, below 18°F/-8°C) or shorted (<328 ohms, above…F3E5Second moisture sensor strip is open or shorted (only Quad Sensing models, only appears…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4Blocked coin 2 or coin drop UI control circuit failure (coin recognition and customer…F4E4Low line voltage detected.F5Not receiving communications from installed debit card reader in Enhanced (Generation 2)…F6Voltage detected below 90 VAC for 8 seconds.F6E1Communication between the ACU and HMI has not been detected.F6E2Communication between the ACU and HMI has not been detected.F7UI is not receiving communications from CCU (cycles and price display disabled while…F70UI is not receiving communications from CCU (cycles and price display disabled while…F71CCU is not receiving communications from UI (cycles and price display disabled while…F73UI Microprocessor is not able to read or verify EEPROM (cycles and price display disabled…F74UI EEPROM memory is a CRC failure (cycles and price display disabled until diagnostic…F8UI Microprocessor is not able to read or verify EEPROM (cycles and price display disabled…f8 e1No voltage detected at the water valve relay (steam models only)F9UI EEPROM memory is a CRC failure (cycles and price display disabled until diagnostic…FCE1WIFI module has not responded for a specified amount of time.FEPower source frequency errorFILLNormal idle/ready state display indicating the dryer is ready to accept a cycle…FLAME FAULTFlame was detected during trial for ignition but failed sometime after; must reoccur for…GAS SUPPLY FAULTHigh or low gas pressure condition detected by the HI/LO gas pressure switch, causing…hEHeating errorHEATER FAULTBurner fan air switch did not close within 10 seconds of blower start-up, or combustion…HI-TEMP FAULTOne or more hi-limit temperature sensors (exhaust, intake, or over-burner) has detected…HotPossible overheating condition detected; the microprocessor controller has detected…IGNITION FAULTGas valve return signal was lost during the DSI proof time and retry count has been…INTAKE DSFLIntake air temperature control sensor has detected a fault condition (optional sensor).L2Low or no line voltage detected (less than 50V) at installation.LEVEL FAULTDryer is not in a level position; one or both tilting level switches are in the normally…LINT ACCESS OPENIndicates the lint drawer is open and needs to be closed.LOW VOLTAGE FAULTIndicates power has dropped below the operating values and will shutdown.MAIN DOOR OPENEDA main door is open when it should be closed.MODEL ERRORThe wrong model was selected for the dryer.MODEL ERROR, ENTER CORRECT MODELController detected a mismatch between programmed dryer type and actual inputs (sail…oPThermistor is open or temperature near the thermistor has fallen below 30°F, causing the…OPEN EXHAUST TEMPERATURE PROBEIndicates the exhaust temperature probe is open or shorted.OPEN S.A.F.E. SYSTEM PROBE FAULTIndicates the temperature probe for the S.A.F.EOPEN THERMISTOR PROBES.A.F.EPFA power failure occurred while the dryer was running.PUSHAmount to start has been insertedROTATION FAULTIndicates the tumbler is not rotating.ROTATION SENSOR FAULTTime between rotational sensor pulses exceeded 10 seconds, indicating tumbler is not…S.A.F.E. SYSTEM ACTIVATEDController has detected a fire condition and is currently extinguishing the flame by…S.A.F.E. SYSTEM DISABLEDA fault in the S.A.F.ES.A.F.E. SYSTEM WAS ACTIVATEDController detected a fire condition and has completed the extinguishing process.SAIL SWITCH CLOSED FAULTSail switch is in the closed position prior to starting; switch did not open within 10…SAIL SWITCH OPEN FAULTSail switch did not close within 8 seconds of starting/restarting, or sail switch opened…SEFLRotational sensor circuit failure indicating a fault in the basket (tumbler) rotation…SHThermistor is shorted or the temperature near the thermistor has risen above 175°F…SHORTED THERMISTOR PROBES.A.F.ESHORTED WATER VALVES.A.F.ETRACExhaust thermistor open-temperature drops below 18°F (>50 kΩ) for 1 minute in Run mode…tSThermistor short sensedWATER NOT CONNECTEDNo water pressure at the S.A.F.E

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.