Model reference
GE GFDL110EH0WW
Dryer
2 documents25 error codes12 service modes
Available documentation
Service Manual
- GE GFDL110EH0WW Dryer Minimanual2 pg
- Technical Service Guide - UltraFresh Dryer59 pg
MyPros+ Max
Diagnose your GE GFDL110EH0WW.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
1Inlet thermistor failure10Empty drum detection tripped11Blocked vent13Door switch signal stuck closed14Door latch pulsing error15Critical flood level by gallons19Door latch lost in run2Outlet thermistor failure6Stuck button8Door latch stuck9Dry load detection tripE00General error affecting all functions.E01EEPROM read/write problem.E02Inlet thermistor shorted.E03Outlet thermistor shorted.E04Inlet thermistor open circuit.E05Outlet thermistor open circuit.E06UI type stored in EEPROM does not match the physical UI present.E07A button is stuck in the pressed position.E60Door switch is open.E61Control board miswired; L2 and N are miswired (AC input too high).E62AC line frequency detection error and low input voltage at control board.E7Miss wireE80Invalid UI model detected on control board.E81Invalid power model detected on control board.Service modes (12)
- Consumer Fault Code ModeFrom an idle state only (all LEDs off), press and hold the Start pad for 10 seconds
- Service ModeFrom an idle state (all LEDs off) or from a standby state (LEDs on but no cycle running), press and…
- T01 - UI ConfigurationIn service mode, select T01 and press Start/Pause
- T02 - Error CodesIn service mode, select T02 and press Start/Pause to display error codes
- T03 - Version InfoIn service mode, select T03 and press Start/Pause
- T04 - EEPROM CheckIn service mode, select T04 and press Start/Pause
- T05 - UI TestIn service mode, select T05 and press Start/Pause
- T06 - Keys ContinuityIn service mode, select T06 and press Start/Pause
- T07 - Outlet ThermistorIn service mode, select T07 and press Start/Pause
- T08 - Inlet ThermistorIn service mode, select T08 and press Start/Pause
- T09 - Moisture SensorIn service mode, select T09 and press Start/Pause
- T10 - Steam TestIn service mode, select T10 and press Start/Pause
Full entry steps, exit procedures, and test sequences are available in Max.
Related GE dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass