16 documents94 error codes32 service modes
Available documentation
Tech Sheet
- Kenmore Whirlpool Dryer 110 C60092991 Tech Sheet16 pg
- Tech Sheet W10156035A 110 78062801 Oasis Steam Dryer16 pg
- Kenmore Whirlpool Dryer 110 85089401 Tech Sheet 855965212 pg
- Tech Sheet - Kenmore Dryer 1108 pg
- TECH SHEET - Kenmore Dryer 110 7299218 pg
- Kenmore Whirlpool Dryer 110 63052101 Tech Sheet 39797178 pg
- Tech Sheet 8546207 110 C85872401 Dryer16 pg
- Kenmore Whirlpool Dryer 110 C69822801 Tech Sheet W1023154512 pg
- Kenmore Whirlpool Dryer 110 73932102 Tech Sheet 39800538 pg
- TECH SHEET - Kenmore Whirlpool Dryer 110 8709160112 pg
- TECH SHEET - Kenmore Whirlpool Dryer 110 9708160112 pg
- Kenmore Dryer 110 64972301 Tech Sheet8 pg
- TECH SHEET - Dryer Diagnostic Guide8 pg
- TECH SHEET - Kenmore Whirlpool Dryer 110 9586140012 pg
Service Manual
- Gas & Electric Dryers - Cabrio116 pg
Wiring Diagram
- Oasis Dryer Wiring Sheet1 pg
MyPros+ Max
Diagnose your Whirlpool 110.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (94)
CodeMeaning
AFRestricted airflow condition exists (electric dryers only).CAAverage current limit tripCECommunications errorCIInstantaneous current limit tripE1Thermistor openE2Thermistor shortedE3User interface or software mismatch between console electronics and machine…ErProcessor reset errorF-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-20Heater #1 failure (electric dryers only).F-21Heater #2 failure on dual element models (electric dryers only).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-24Inlet thermistor is open (only appears in diagnostic test mode, electric dryers…F-25Inlet thermistor is shorted (only appears in diagnostic test mode, electric…F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted airflow condition (only appears in diagnostic test mode, electric…F-40Communication between the machine control and motor control is lost.F-41Blower motor failure.F-42Motor control detects a voltage less than 90 VAC (undervoltage failure).F-43Motor control detects a low voltage condition; dryer continues to run at a set…F-44Motor control electronics failure.F-45Motor control electronics speed sensor failure.F-46Motor control detects an over-current or over-torque condition on the blower…F-50No voltage detected at the water valve relay (steam model only, appears only in…F:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).View all 94 error codes
F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted airflow condition exists (only appears in diagnostic test mode).F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.F/01EEPROM communication error between the Central Control Unit (CCU) and the…F/02Long drainF/05Water temperature sensor (NTC) errorF/06Drive motor tachometer errorF/07Motor Control Unit (MCU) errorF/09Overflow conditionF/10Motor Control Unit (MCU) heat sink thermal tripF/11Serial communication errorF/13Dispenser circuit errorF/14EEPROM errorF/15Motor Control Unit (MCU) errorF/20No water detected entering machine or pressure switch trip not detected…F/21Long drain error; drain time exceeds 8 minutes and water valves turn off.F/22Door lock error; after 6 failed attempts to lock the door.F/24Water temperature sensor (NTC) error; value is out of range (-5°C to 103°C)…F/25Drive motor tachometer error; control is unable to properly detect motor speed…F/26Door switch error; door has not been opened for 3 consecutive cycles or door…F/27Overflow condition; overflow contact on the pressure switch is closed for more…F/28Serial communication error; communication between the CCU and MCU cannot be…F/29Door unlock error; door unlock has failed 6 times.F/30Dispenser system error; dispenser motor cannot be driven to its proper position.F/31MCU failure; thermal protector on the MCU heat sink gets too hot, stopping…F/33Pump drive system error; connection between pump and the Central Control Unit…F/34Clothes still inside drum during the Cleaning Washer Cycle; load detected…F/dLDoor lock errorF/dUDoor unlock errorF/HNo water detected entering machine or pressure switch trip not detectedF0Load detected in drum at start of CLEAN WASHER cycle (detection by weight).F1Water temperature sensor (NTC) value is out of range (23°F to 217°F / -5°C to…F2Motor Control Unit (MCU) has internal failure; if failure occurs during…F3Overflow conditionF4Dispenser system errorF5Pump driver fails to activate, one of the main relays is not working properly…F6Door switch errorF7Serial communication errorF8No water detected entering machine or pressure switch trip not detected…F9Pump drive system errorFLOverfill conditionLdLong drainLFLong fillLSLid switch errorobOff balancePFPower failure occurred while the dryer was running.SdSuds lockSLSuds lockSrStuck relaySudSuds lock
Service modes (32)
- Adjusting Customer-Focused Drying Modes (CF1/CF2/CF3)1
- Automatic Service DiagnosticsWith control OFF, press PREWASH OPTIONS → WASH TIME → PREWASH OPTIONS → WASH TIME within 5 seconds.
- Console Diagnostics (within Diagnostic Test Mode)["Enter Diagnostic Test Mode.","Press each button to verify it causes a beep tone and controls its…
- console_switches_and_indicators_diagnostic["Enter the diagnostic test mode.","Press each button to verify it causes a beep tone and controls…
- Customer-Focused Drying Mode Adjustment1
- damp_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to known good power…
- diagnostic["Set Fabric Care / Temperature switch to AIR FLUFF / NO HEAT","Set Signal switch to LOUDER","Set…
- Diagnostic Test["Begin with fully assembled dryer connected to known good power source.","Open the door.","Set…
- Diagnostic Test Mode1
- diagnostic_test["Ensure door is open.","Set Fabric Care / Temperature switch to AIR FLUFF / NO HEAT.","Set Signal…
- diagnostic_test_mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Press the following…
- Displaying Inlet Air Flow DiagnosticAfter all saved fault codes have been displayed in diagnostic test mode, press the Wrinkle Guard…
- Displaying Line Voltage DiagnosticAfter all saved fault codes have been displayed in diagnostic test mode, press the Cycle Signal…
- door_switch_diagnostic["Enter the diagnostic test mode.","Open the door
- Dryness Level Adjust (TEST #4a)["Activate the Diagnostic Test Mode (MORE TIME → LESS TIME → MORE TIME → LESS TIME within 5…
- dryness_level_adjust["Enter the diagnostic test mode (MORE TIME → LESS TIME → MORE TIME → LESS TIME within 5…
- Keypad and LED TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
- Less Dry Test["Begin with fully assembled, empty dryer with clean lint screen connected to known good power…
- less_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to known good power…
- Line Voltage DisplayAfter all saved fault codes have been displayed in diagnostic mode, press the Cycle Signal Volume…
- Manual Diagnostic Test["Washer must be empty and control must be in OFF state.","Close the door.","Press and hold any key…
- Manual Load Test1
- moisture_sensor_diagnostic["Enter the diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Nutate and Recirculate TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
- Quick Diagnostic Test (bypassing Service History)["Ensure drum is empty.","Close the door.","Push POWER.","Select the CLEAN WASHER cycle.","Press…
- Quick Entry Diagnostic Test (bypasses Service History)["Execute with an empty drum.","Close the door.","Push CONTROL/ON.","Select the DRAIN/SPIN…
- Saved Fault Code DisplayAfter entering diagnostic test mode, if saved fault codes exist, the most recent fault code…
- Service Diagnostic Test Mode1
- Service History Mode & Diagnostic Test["Ensure washer is empty and control is in OFF state.","Close the door.","Select any one key…
- Service History Mode & Diagnostic Test (Universal)["Washer must be empty and control must be in OFF state.","Close the door.","Press and hold any key…
- Spin and Drain TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
- Water Inlet and Dispenser Valve Operating PS TestWith control OFF, press SET DELAY TIME → END OF CYCLE SIGNAL → SET DELAY TIME → END OF CYCLE SIGNAL…
Full entry steps, exit procedures, and test sequences are available in Max.