Skip to main content
Miele Refrigerator Error Codes
69 error codes for Miele refrigerator models. Each links to the full diagnostic procedure from the service manual.
MyPros+ Max
Get the full diagnostic procedure for any Miele refrigerator error code.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts
- Verified part numbers when replacement is required
Get started
$29/month · Cancel anytime · Or $9.95 3-day pass
3-4-4Icemaker3-4-5Icemaker4-1-1Icemaker4-2-1Icemaker4-3-1Icemaker4-4-1Icemaker5-1-1Icemaker5-2-1Icemaker5-3-1Icemaker5-4-1Icemaker5-5-1IcemakerF0SmartFresh NTC defective (short- or open-circuited); emergency operationF1Refrigerator air NTC defective (short- or open-circuited); emergency operationF110Refrigerator air NTC faulty (resistance corresponds to temperature below…F111Freezer air NTC faulty (resistance corresponds to temperature below -66°F/-55°C…F112SmartFresh NTC faulty (resistance corresponds to temperature below -66°F/-55°C…F115Refrigerator evaporator NTC faulty (resistance corresponds to temperature below…F116Freezer evaporator NTC faulty (resistance corresponds to temperature below…F120Voltage below 95VAC (not visible to customer).F121Defective icemaker.F122Ambient air NTC faulty (resistance corresponds to temperature below -66°F/-55°C…F123Refrigerator temperature alarmF124Freezer temperature alarmF125SmartFresh temperature alarmF127Faulty connection between control and power electronics, or faulty…F141Refrigerator door open for 15 minutes (not visible to customer).F142Refrigerator door open for 30 minutes (not visible to customer).F143Refrigerator door open for 45 minutes (not visible to customer).F144Freezer door open for 15 minutes (not visible to customer).F145Freezer door open for 30 minutes (not visible to customer).F146Freezer door open for 45 minutes (not visible to customer).F147Compressor area overtemperature (above 135°F/57°C detected 3 times for at least…F2Refrigerator evaporator NTC defective (short- or open-circuited); emergency…F3Freezer air NTC defective (short- or open-circuited); compressor runs…F4Freezer evaporator NTC defective (short- or open-circuited); compressor runs…F41Faulty power electronic.F5Bottom compartment air NTC (B22) defective; compressor and heaters are switched…F6Factory production self-test fault code displayed due to inability to comply…F7Factory production self-test fault code displayed due to inability to comply…F8Factory production self-test fault code displayed due to inability to comply…F9Factory production self-test fault code displayed due to inability to comply…FAFactory production self-test fault code displayed due to inability to comply…FCFactory production self-test fault code displayed due to inability to comply…FdFactory production self-test fault code displayed due to inability to comply…FEEEPROM fault; electronic is defective.FPFactory production self-test fault code displayed due to inability to comply…FUAmbient air NTC defective (displayed in service mode instead of rd); control…nAFreezer interior too warm after a break in power supply.SEFactory production self-test fault code displayed due to inability to comply…