Model reference
Fisher & Paykel DEIX2
Dryer
14 documents25 error codes28 service modes
Available documentation
Service Manual
- Electronic Models DEIX2 DGIX2 DE62T27GW DG62T27GW Supplementary Service Manual25 pg
- Supplementary to Issue B March 2005 – 517760B25 pg
- Fisher Paykel Smartload Intuitive Dryer Service Manual25 pg
- Gas & Electric Dryers Service Summary5 pg
- INTUITIVE & AEROSMART DISPLAY MODULE - Gas & Electric Dryers Service Summary5 pg
Bulletin
- No Heat – SmartLoad® and Intuitive® Top Loading Dryers1 pg
- Long Drying Times2 pg
- New Model Introduction - DEIX2, DGIX2 Dryers Service Bulletin6 pg
- Service Bulletin13 pg
- FPBulletins408 - Washers & Dryers Change in Models and Product Codes / AquaSmart Size Setting12 pg
Service Flash
- Introduction of New Actuator Assembly1 pg
Other
- 395623C4 pg
- S FDRT 09 04 Tripping Thermostat4 pg
- SFDRT0601Long Drying Times2 pg
MyPros+ Max
Diagnose your Fisher & Paykel DEIX2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (25)
CodeMeaning
1Communications failure between the sensor module and motor control module.1024 Volt supply measurement error105Communications failure between the sensor module and display module (Intuitive…11Lid lock open circuit.12Lid lock switching device failure.14Sensor module fault.15Sensor module fault.16Airflow restriction (user warning).2Drum gap cannot be located.20Door actuator stalled.21Door actuator required excess voltage.22Door actuator open circuit.23Door actuator movement interrupted by low voltage (brown out).24Door actuator movement took too long.28Data retrieval error following loss of power.29Brown-out data retrieval error.3Drum stalled.30Lid lock unable to lock (user warning)4Invalid option link read45Display Module ROM Check Error6Door jammed7Motor current excessive.7bDisplay module RAM check error8Exhaust sensor over temperature9Exhaust sensor under temperatureService modes (28)
- Adjust Options Menu - Intuitive Model1
- Adjust Options Menu – Intuitive Model["Press Power to turn the machine on.","Push the Options Up or Options Down button and hold for 2…
- Conductivity Contact Test - AeroSmart LED ModelEnter diagnostic mode as described for AeroSmart LED, then press the Time Dry button five times
- Conductivity Contact Test Mode – AeroSmart LED Model["Enter diagnostic mode (press and hold Wrinkle Free, then press Power).","Press the Time Dry…
- Data Display - Intuitive ModelAfter entering Diagnostic Mode, push the Lifecycles button again
- Data Download Mode - AeroSmart LCD ModelEnter diagnostic mode as described for AeroSmart LCD, then press the Start/Pause button
- Data Download Mode - AeroSmart LED ModelEnter diagnostic mode as described for AeroSmart LED, then press the Start/Pause button
- Data Download Mode - Intuitive ModelEnter diagnostic mode, then press the Start/Pause button
- Data Download Mode – AeroSmart LCD Model["Enter diagnostic mode (press and hold Wrinkle Free then Select).","Press the Start/Pause…
- Data Download Mode – AeroSmart LED Model["Enter diagnostic mode (press and hold Wrinkle Free then Power).","Press the Start/Pause…
- Data Download Mode – Intuitive Model["Enter diagnostic mode (press and hold Lifecycles then Power).","Press the Start/Pause…
- Diagnostic Mode - AeroSmart LCD ModelPress and hold the Wrinkle Free button and then the Select button
- Diagnostic Mode - AeroSmart LED ModelPress and hold the Wrinkle Free button (button A) and then the Power button (button B)
- Diagnostic Mode - Intuitive ModelPress and hold the Lifecycles button and then the Power button
- Diagnostic Mode – AeroSmart LCD Model["Press and hold the Wrinkle Free button.","Then press the Select button.","The machine will give 2…
- Diagnostic Mode – AeroSmart LED Model["Press and hold the Wrinkle Free button (button A).","Then press the Power button (button…
- Diagnostic Mode – Intuitive Model["Press and hold the Lifecycles button.","Then press the Power button.","The machine will give 2…
- Diagnostic Mode A (AeroSmart LCD)["Ensure power supply to the machine is switched on.","Press and hold the Wrinkle Free button, then…
- Diagnostic Mode A (AeroSmart LED) – Conductivity Impedance Check["Enter the diagnostic mode (AeroSmart LED).","Press the Time Dry button five times."]
- Diagnostic Mode A (AeroSmart LED) – Last Fault Option["Press and hold the WRINKLE FREE button (button A) and the POWER button (button B).","The dryer is…
- Diagnostic Mode A (LED) – Conductivity Impedance Check["Enter diagnostic mode (AeroSmart LED).","Press the Time Dry button five times."]
- Diagnostic Mode G – Conductivity Impedance Check["Enter diagnostic mode (General).","Press the Auto Dry up button five times."]
- Diagnostic Mode G (General) – Last Fault Option["Turn the power supply to the dryer on.","Press and hold the Wrinkle Free down button, while…
- Diagnostic Mode I (Intuitive)["Ensure power supply to the machine is switched on.","Press and hold the Lifecycles button, then…
- Diagnostic Mode I and A (LCD) – Conductivity Impedance Check["Enter diagnostic mode for Intuitive or AeroSmart LCD.","Navigate to the Machine Status…
- Showroom Mode["Turn the power supply to the dryer on.","Ensure that the display is off.","Press and hold the…
- Showroom Mode - Intuitive Model1
- Showroom Mode – Intuitive Model["Turn the power supply to the dryer on.","Ensure that the display is off.","Press and hold the…