Model reference
GE CYE23TSDBSS
Refrigerator
3 documents85 error codes3 service modes
Available documentation
Service Manual
- ServiceManual CC CafeBFRefrigerator89 pg
- GE CYE23TSDFSS Mini Manual4 pg
Tech Tip
- Articulating Mullion Not Engaging1 pg
MyPros+ Max
Diagnose your GE CYE23TSDBSS.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (85)
CodeMeaning
0001FF Thermistor reading out of range.0003FZ Thermistor reading out of range.0004FZ Evaporator Thermistor reading out of range.0005Electronic Deli Pan Thermistor reading out of range.0006FF Evaporator Thermistor reading out of range.0008Ambient Temperature Thermistor reading out of range.0009Ambient Humidity Sensor reading out of range.0010FZ Icemaker Thermistor reading out of range (if applicable).0100FZ Fan Feedback Missing when Fan is running.0104Condenser Fan Feedback Present when Fan is off.0110Ice Box Fan Feedback Present when Fan is off.0115Odor Remover Fan Feedback Missing when Fan is running.0200FZ Defrost Heater timed out (check FZ Evap thermistor fault code 0004).0500Can't reach Target Hot Water Temp.0700Stuck keys on Dispenser Boards.0722Display board error.F1FF1 Thermistor Invalid.F10Ice Mold Body Thermistor (MB) Invalid.F100FZ Fan Feedback Missing when Fan is running.F101FZ Fan Feedback Present when Fan is off.F102FZ Fan cannot reach target RPM.F103Condenser Fan Feedback Missing when Fan is running.F104Condenser Fan Feedback Present when Fan is off.F105Condenser Fan cannot reach target RPM.F106FF Fan Feedback Missing when Fan is running.F107FF Fan Feedback Present when Fan is off.F108FF Fan cannot reach target RPM.F109Ice Box Fan Feedback Missing when Fan is running.F110Ice Box Fan Feedback Present when Fan is off.F111Ice Box Fan cannot reach target RPM.View all 85 error codes
F112Deli Pan/FP Fan Feedback Missing when Fan is running.F113Deli Pan/FP Fan Feedback Present when Fan is off.F114Deli Pan/FP Fan cannot reach target RPM.F115Odor Filter Fan Feedback Missing when Fan is running.F116Odor Filter Fan Feedback Present when Fan is off.F117Odor Filter Fan cannot reach target RPM.F2FF2 Thermistor Invalid.F200FZ Defrost Heater on for Max Time (defrost turns off based on time).F201FF Defrost Heater on for Max Time (defrost turns off based on time).F2025 consecutive FZ abnormal defrosts.F2035 consecutive FF abnormal defrosts.F3FZ Cabinet Thermistor Invalid.F300Excessive Compressor Run Time (compressor ran for 5 hours; initial cycle at…F301Compressor off for 3 hours with Cooling System turned on.F302FF No Freeze Limit Tripped (FF crossed the No Freeze Limit).F303FF Temp Exceeded.F304FZ Temp Exceeded.F305Dampers Stuck Closed.F306Damper Stuck Open.F4FZ Evaporator Thermistor Invalid.F400Main Board FailureF401Ice/water stops dispensing based on time (7 Minute Timeout); only on SxS models…F5FP/Deli Pan Thermistor Invalid.F500Can't reach Target Hot Water Temp.F6FF Evaporator Thermistor Invalid.F600FF Icemaker Multi-fill active 3 times in the last 10 fills.F601FF Icemaker Stuck in Harvest Fix Mode (after 10 minutes stuck in Harvest Fix…F602FF Icemaker enters harvest fix mode 3 out of 10 harvests.F603FF Icemaker enters Fault Mode after entering Harvest Fault.F650FZ Icemaker Multi-fill active 3 times in the last 10 fills.F651FZ Icemaker Stuck in Harvest Fix Mode (after 10 minutes stuck in Harvest Fix…F652FZ Icemaker enters harvest fix mode 3 out of 10 harvests.F653FZ Icemaker enters Fault Mode after entering Harvest Fault.F7Convertible Drawer Thermistor Invalid.F700Stuck keys on ICID/ACM (Dispenser Boards).F701Stuck Keys on Internal Temp Board.F702Stuck Keys on Deli Pan.F703Key inputs on Deli Pan Temp Board and Door Closed (FF Door is closed and a Key…F704Key Inputs on Deli Pan/FP Board and Door Closed (FF Door is closed and a key…F705Auto fill Communication Error (AutoFill Module not communicating properly).F706Auto fill wrong version (not compatible with the ACM Version).F707ACM/Comm Communication Error (COM Module not communicating properly).F708COM Wrong Version (not compatible with the ACM).F709Cold Water Cup Switch Input missing and 0x70 message is received from COM (ACM…F710Cold Water Cup Switch Input present and no dispense message is received from…F711Hot Water Cup Switch Input missing and dispense message is received that…F712Hot Water Cup Switch Input present and no dispense message is received (ACM…F713FF Door open for 15 minutes without closing.F714FF Door open for 60 minutes in the last 24 hours.F71550 FF Door Openings in the last 24 hours.F716FZ Door open for 15 minutes without closing.F717FZ Door open for 60 minutes in the last 24 hours.F71850 FZ Door Openings in the last 24 hours.F8Ambient Temperature Invalid.F9Ambient Humidity Invalid.
Service modes (3)
- Cooling System Off ModeOn non-dispenser temperature control models, press and hold 'Refrigerator' and 'Freezer' buttons…
- Retrieve Failure CodesEnter Service Diagnostics mode (press and hold Water, Crushed & Cubed for 3 seconds, select Yes)
- Service DiagnosticsPress and hold 'Water', 'Crushed' & 'Cubed' pads together for 3 seconds to enter Service Mode
Full entry steps, exit procedures, and test sequences are available in Max.