Model reference
LG FM57AH
Air Conditioner
1 document37 error codes6 service modes
Available documentation
Service Manual
- Air Conditioner Service Manual - Multi-Inverter Type137 pg
MyPros+ Max
Diagnose your LG FM57AH.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (37)
CodeMeaning
01Indoor air sensor open/short circuit error.02Indoor inlet pipe sensor open/short circuit error.03Communication error between indoor unit and wired remote controller.04Drain pump / float switch error (float switch open).05Communication error between indoor and outdoor units (displayed on indoor unit).06Indoor outlet pipe sensor open/short circuit error.07Different operation mode error09Indoor EEPROM check sum error.10Indoor BLDC fan motor lock21DC Peak / IPM Fault22CT2 / Max CT23DC link low voltage24Low pressure / high pressure switch open.25Abnormal AC input voltage (below 140Vac or above 300Vac).26DC compressor position detect error27PSC/PFC fault error28DC link high voltage29Inverter compressor over current32Inverter compressor discharge pipe temperature high (over 105°C).33Constant compressor discharge pipe temperature high (over 105°C).39Communication error between PFC micom and INV micom on inverter PCB.40CT sensor circuit malfunction (open/short).41Inverter discharge pipe thermistor error (open/short).44Outdoor air thermistor error (open/short).45Condenser pipe thermistor error (open/short).46Suction pipe thermistor error (open/short).47Constant compressor discharge pipe thermistor error (open/short).51Over capacity combination52Signal/transmission error between inverter PCB and main PCB.53Communication error between indoor and outdoor units (displayed on outdoor…View all 37 error codes
543-phase wrong wiring of outdoor unit (reverse phase or phase omission).60EEPROM check sum error on outdoor unit (inverter PCB and/or main PCB).61Condenser pipe thermistor detected high temperature (65°C).62Heat sink thermistor detected high temperature (85°C).65Heat sink thermistor error (open/short).67Outdoor BLDC fan lock73PFC fault error (software)
Service modes (6)
- Child LockPress the preset and minute setup buttons simultaneously for 3 seconds
- E.S.P. (External Static Pressure) Setting1
- Forced OperationPress the ON/OFF button on the indoor unit display panel. The operating condition is set…
- Test Run (Cassette type)Press the button on the indoor unit for 5 seconds to start test run
- Test Run (Ceiling Cassette type)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (Room/Wall type)Press the timer cancel button five times continuously on the indoor unit.
Full entry steps, exit procedures, and test sequences are available in Max.