Model reference
LG S36AW
Air Conditioner
2 documents37 error codes6 service modes
Available documentation
Service Manual
- Air Conditioner Service Manual - Single "A"-Inverter Type113 pg
Tech Sheet
- Inverter Single 50Hz/R410A Product Data111 pg
MyPros+ Max
Diagnose your LG S36AW.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (37)
CodeMeaning
01Indoor room thermistor error (open/short or faulty sensor).02Indoor inlet pipe sensor error (open/short or faulty sensor).03Remote controller communication error (wired remote controller).04Drain pump / float switch error.05Communication error between indoor and outdoor units.06Indoor outlet pipe sensor error (open/short or faulty sensor).07Different mode operation error.09EEPROM checksum error (indoor).10BLDC motor fan lock (indoor).21DC Peak / IPM Fault22CT2 Max current23DC Link low voltage (1ph24Low pressure / high pressure switch open.25Low voltage / over voltage.26DC compressor position detect error.27PFC/PSC fault error28DC Link high voltage (1ph29Inverter compressor over current32Discharge pipe temperature high for inverter compressor (≥105°C).33Discharge pipe temperature high for constant compressor (≥105°C).39Communication error between PFC Micom and INV Micom.40CT sensor error (open/short)41Inverter discharge pipe thermistor error (open/short).44Outdoor air thermistor error (open/short).45Condenser pipe thermistor error (open/short).46Suction pipe thermistor error (open/short).47Constant compressor discharge pipe thermistor error (open/short).51Over capacity52Transmission error between inverter PCB and main PCB53Communication signal error between indoor and outdoor units (displayed at…Service modes (6)
- Auto Addressing (Synchro Operation)1
- Child LockPress the preset and minute setup button simultaneously for 3 seconds
- E.S.P. (External Static Pressure) Setting Mode1
- Forced OperationPress the ON/OFF button on the main unit display panel (for use when remote control is lost).
- Installer Setting ModePress the designated button for 4 seconds until function code is displayed on the bottom of the LCD…
- Test Run ModeFor ceiling cassette type
Full entry steps, exit procedures, and test sequences are available in Max.