Model reference
Whirlpool WGE755C0BH00
Range
6 documents51 error codes16 service modes
Available documentation
Tech Sheet
- Fiche technique - Tech Sheet - W10600809 - Rev A (FR)24 pg
- Tech Sheet - W10600805 - Rev A16 pg
- Tech Sheet64 pg
- Tech Sheet - W10647745 - Rev B64 pg
Installation Guide
- Installation Instructions20 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Whirlpool WGE755C0BH00.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (51)
CodeMeaning
C-81Induction cooktop over temperature (Type 2 failure).C-82Induction cooktop over temperature (Type 2 failure).C-83Induction cooktop temperature sensor stuck (Type 2 failure).F-12Induction cooktop coil under current (Type 1 failure, affects only one burner).F-21Induction cooktop supply power frequency error (Type 2 failure, affects all…F-25Stuck fan on Induction Power System (IPS)F-36Induction cooktop temperature sensor is not working (Type 1 failure).F-37Induction cooktop temperature sensor is not working (Type 1 failure).F-40Induction Power System (IPS) failure (Type 1 or Type 2).F-42Induction cooktop power supply issue (Type 2 failure).F-43Induction cooktop under voltage (Type 2 failure).F-47Power supply from Induction Power Control (IPC) to User Interface is missing…F-56Wrong or invalid configuration (Type 3 failure, disables entire cooktop).F-58Wrong or invalid configuration (Type 2 failure).F-60UI does not work (Type 3 failure, disables entire cooktop).F1-E0EEPROM communication error (internal).F1-E1Upper RTD uncalibrated (internal).F1-E2Lower RTD uncalibrated (internal).F1-E5Sensor usage out of range (internal).F1-E7PCB thermistor/sensor open or shorted.F1-E9WIDE Queue full.F1E0EEPROM communication error (internal control fault).F1E1Upper RTD sensor not calibrated (internal control fault).F1E2Lower RTD sensor not calibrated (internal control fault).F1E5Sensor usage out of range (internal control fault).F1E7PCB sensor/thermistor open or short-circuited.F1E9WIDE queue full.F2-E0Keypad disconnected.F2-E1Stuck key detected.F2-E2Stuck key detected.View all 51 error codes
F2E0Keypad disconnected from oven control module.F2E1Stuck key detected on keypad.F2E2Stuck key detected on keypad.F3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Upper (main) oven temperature sensor open or short-circuited.F3E1Lower (main) oven temperature sensor open or short-circuited.F5-E0Door and door position switch(es) do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door switch and door position switch mismatch during clean mode.F5E1Door latch does not operate properly during clean mode.F6-E0Lost communications between control components.F6-E1Over temperature condition during cook mode (runaway temperature).F6-E2Over temperature condition during clean mode (runaway temperature).F6-E3Over temperature condition in warming drawer (runaway temperature).F6E0Loss of communications between control modules.F6E1Bake mode runaway temperature (oven temperature exceeded safe limit during…F6E2Clean mode runaway temperature (oven temperature exceeded safe limit during…F6E3Warming drawer runaway temperature (exceeded safe limit).F9-E0Product is mis-wired.F9E0Product is miswired (incorrect wiring detected).
Service modes (16)
- Control Reset (Soft Reset)1
- Cooktop Controls Diagnostic ModePress any 3 different keypads in sequence
- Cooktop Controls Diagnostics ModePress any 3 different keypads in sequence
- Diagnostic ModePress CANCEL > CANCEL > START
- Diagnostics ModePress CANCEL > CANCEL > START
- Display Test1
- Faults (View/Clear Error Codes)1
- Oven Diagnostics ModePress CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds. Use TEMP/TIME +/- or More/Less keypads or…
- Oven Test Mode (Manual Relay Activation)Enter Diagnostics Mode (CANCEL>CANCEL>START or OFF>OFF>ON within 5 seconds). Navigate with…
- Semi Automatic Test Mode1
- Semi-Automatic Test1. Enter diagnostic mode (CANCEL > CANCEL > START). 2. Press TEMP/TIME '+' or '-' (or keys 3 or 6…
- Temperature Calibration1
- Test Mode1
- Test Mode (Manual Relay Activation)1
- Usage Mode1
- Version1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass