Fisher & Paykel RF201ADUX-22302A

Refrigerator

1 document35 error codes13 service modes

Available documentation

Service Manual

  • Diagnostic Manual17 pg
    Covers this model
MyPros+ Max

Diagnose your Fisher & Paykel RF201ADUX-22302A.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (35)

CodeMeaning
1On the last power up, the power module failed self test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected14The low ambient heater is drawing more current than expected15The PC fan is drawing less current than expected16The PC fan is drawing more current than expected17The FC fan is drawing less current than expected18The FC fan is drawing more current than expected2The previous 2 defrosts were aborted after 40 minutes.20The flapper heater current is low.21The flapper heater current is high.22The resistance of the PC sensor 2 is outside the normal range (> 45K Ohms).23The resistance of the PC sensor 2 is outside the normal range (< 660 Ohms).24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms).25The resistance of the ice tray sensor is outside the normal range (< 660 Ohms).26The icemaker timer has timed out; the icemaker gearbox is not returning to the…27The icemaker motor current is high.28Icemaker solenoid current high.29Icemaker solenoid current low.3The resistance of all the temperature sensors is outside the normal range (>…32Water dispenser solenoid driver 1 has failed; product reverts to solenoid…33Water dispenser solenoid driver 2 has failed; solenoid driver 1 may still be…34Both water dispenser solenoid drivers have failed.4The resistance of all the temperature sensors is outside the normal range (<…40Icemaker solenoid transistor 1 short circuit on the control module.41Icemaker solenoid transistor 2 short circuit.5The resistance of the FC sensor is outside the normal range (> 45K Ohms).6The resistance of the FC sensor is outside the normal range (< 660 Ohms).
View all 35 error codes

Service modes (13)

  • Data Download ModePress and hold the MENU button, then press the UP button for 4 seconds (to enter Diagnostic mode)…
  • Diagnostic Mode (From January 2009, non measured fill)Press and hold the MENU button, then press the UP button and hold both for 4 seconds.
  • Diagnostic Mode (Pre-January 2009, with measured fill)Press and hold the MENU button, then press the UP button and hold both for 4 seconds.
  • Flowmeter Calibration (Pre-January 2009)Press and hold Measured Fill + Down + On/Off for 4 seconds.
  • Force Manual Icemaker (From January 2009)Press Lock key first, then press Down + Up keys and hold all 3 keys for 4 seconds
  • Forced Defrost (From January 2009)Press and hold MENU + DOWN for 4 seconds.
  • Input/Output Status1
  • Manually Force Icemaker (Pre-January 2009)Press and hold Measured Fill + Down + Up for 4 seconds
  • Manually Forced Defrost (Pre-January 2009)Press and hold MENU + DOWN for 4 seconds.
  • Sabbath Mode (From January 2009)Press and hold MENU + DOWN + Lock for 4 seconds.
  • Sabbath Mode (Pre-January 2009)Press and hold MENU + Measured Fill + Down + On/Off for 4 seconds.
  • Show Off Mode (From January 2009)Press and hold MENU + DOWN + UP for 4 seconds.
  • Show Off Mode (Pre-January 2009)Press and hold MENU + DOWN + UP + On/Off for 4 seconds.

Full entry steps, exit procedures, and test sequences are available in Max.