LG PMNFP14A0
Air Conditioner
6 documents35 error codes5 service modes
Available documentation
Service Manual
- Air Conditioner Service Manual - Multi-Inverter Type113 pg
- Multi Air Conditioner SVC MANUAL (Exploded View)7 pg
- Multi Air Conditioner SVC MANUAL(Exploded View)7 pg
- SERVICE MANUAL - E-View Multi Air Conditioner12 pg
- SERVICE MANUAL - AIR CONDITIONER E-View Multi Air Conditioner12 pg
Other
- LG Samsung A8UW54GFA012 pg
MyPros+ Max
Diagnose your LG PMNFP14A0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (35)
CodeMeaning
01Indoor room thermistor (air sensor) error02Indoor inlet pipe sensor error03Wired remote controller communication error.04Drain pump / float switch error.05Communication error between indoor and outdoor units.06Indoor outlet pipe sensor error07Different mode operation error09Indoor EEPROM check sum error.10Indoor BLDC fan motor lock21DC link peak / IPM fault22AC input current higher than the limit (CT max / input over current).23DC link high voltage (above 420Vdc) or low voltage (below 140Vdc).25Input voltage abnormal26DC compressor position / starting fail error27PSC/PFC fault error29Inverter compressor over current32High temperature in discharge pipe of the inverter compressor.35Low pressure error39Communication error between PFC Micom and INV Micom.40CT sensor error41Inverter discharge pipe thermistor sensor error43High pressure sensor error44Outdoor air thermistor sensor error45Condenser mid-pipe thermistor sensor error46Suction pipe thermistor sensor error48Condenser out-pipe thermistor sensor error51Over capacity combination53Communication error between indoor and outdoor units543-phase wrong wiring of outdoor unit (reverse phase/omission of phase).60Outdoor unit EEPROM check sum errorService modes (5)
- Forced OperationPress the ON/OFF button on the main unit for 2 seconds.
- Installer Setting Mode (E.S.P. / Two Thermistor Control)Press OPER button and MODE button simultaneously for more than 3 seconds to enter installer setting…
- Pump Down1) Shut power off
- Test Run (Ceiling Cassette type)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (Split/ART Cool type)Press button for 3-6 seconds to start test run.
Full entry steps, exit procedures, and test sequences are available in Max.