9 documents40 error codes19 service modes

Available documentation

Tech Sheet

  • Fast Track Troubleshooting13 pg
    Covers this model

Service Manual

  • REFRIGERATOR BOTTOM MOUNT FREEZER Technical Service Guide5 pg
    Covers this model
  • REFRIGERATOR BOTTOM MOUNT FREEZER Technical Service Guide145 pg
    Covers this model
  • REFRIGERATOR BOTTOM MOUNT FREEZER Technical Service Guide4 pg
    Covers this model

Wiring Diagram

  • LG Samsung RFG295ABRSXAA Schematic Diagram7 pg
    Covers this model
  • LG Samsung RFG297ACWPXAC Schematic Diagram7 pg
    Covers this model

Other

  • LG Samsung RFG297ACRSXAC AW2 RFG297AB SM 091130145 pg
    Covers this model
  • LG Samsung RFG295ABRSXAA AW2 RFG295AB SM 091130141 pg
    Covers this model
  • LG Samsung RFG297ACWPXAC Cover4 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung RFG299ABWP.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (40)

CodeMeaning
1Refrigerator sensor (R-sensor) error detected by self-diagnosis.2Freezer sensor (F-sensor) error detected by self-diagnosis.21Freezer fan error detected by self-diagnosis.22Refrigerator fan error detected by self-diagnosis.24Freezer defrost error detected by self-diagnosis.25Refrigerator defrost error detected by self-diagnosis.26Ice maker function error detected by self-diagnosis.39Ice room fan error detected by self-diagnosis.40Ice room sensor error detected by self-diagnosis.5Defrost sensor error detected by self-diagnosis.6Ambient sensor error detected by self-diagnosis.8Ice maker sensor error detected by self-diagnosis.83Communication error between Main PCB and Pantry PCB.84Communication error between Main PCB and Panel PCB.85Communication error between Main PCB and Sub Micom on Panel PCB.Detecting Position FailureCompressor inverter LED blinks indicating a rotor position detection failure.F-1-ⓐAmbient sensor external system errorF-1-ⓑFreezer compartment (F) sensor system errorF-1-ⓒFreezer compartment defrost sensor (F-DEF) system errorF-1-ⓓFreezer compartment fan motor (F-FAN) errorF-1-ⓔCondenser fan motor (C-FAN) errorF-1-ⓕIce Room sensor system errorF-1-ⓖFreezer compartment defrost heater (F-DEF) errorF-10-ⓑIce Room fan motor errorLow VoltageCompressor inverter LED blinks indicating low input voltage condition.Motor LockedCompressor inverter LED blinks indicating the compressor motor is locked.OP - ErPanel to Main MICOM option errorOver VoltageCompressor inverter LED blinks indicating an over voltage condition.Pc - ErPanel to Main MICOM communication errorR-1-ⓐIce Maker Sensor system error
View all 40 error codes

Service modes (19)

  • Celsius/Fahrenheit TogglePress the Ice Type and Water buttons simultaneously (no sound when both buttons are pressed at the…
  • Check LCD Pixel FunctionRefer to section 4-1-8 (page 63) for LCD pixel check entry procedure.
  • Cooling OffRefer to section 4-1-5 (page 60) for cooling off mode entry procedure.
  • Cooling Off Mode (Exhibition Mode)["Press Energy Saver Key + Freezer Key simultaneously for 3 seconds during normal…
  • Error History FunctionRefer to section 4-1-7 (page 62) for error history function entry procedure.
  • Forced Freeze / Forced Compressor OperationActivate Forced Freeze mode (used to force fans and compressor on for testing).
  • Forced OperationsRefer to section 4-1-1 (page 54) for forced operation entry procedure.
  • Heat Release Ice Maker Test ModePress and hold the ICE TEST S/W for at least 1.5 seconds; the harvest function will start.
  • Load Condition Display Mode["Press Energy Saver Key + Lighting Key simultaneously for 6 seconds during normal…
  • Load Operation CheckRefer to section 4-1-4 (page 59) for load operation check entry procedure.
  • Option Setting Mode["Press Freezer Key + Lighting Key simultaneously for 12 seconds during normal operation.","Fresh…
  • OS Upgrade FunctionRefer to section 4-1-11 (page 68) for OS upgrade entry procedure.
  • S/W UpgradeRefer to section 4-1-12 (page 70) for software upgrade entry procedure.
  • Self-Diagnostic Function["Press Energy Saver Key + Lighting Key simultaneously for 8 seconds during normal…
  • Self-DiagnosticsRefer to section 4-1-3 (page 56) for self-diagnostics entry procedure.
  • Set Point ShiftRefer to section 4-1-6 (page 61) for set point shift entry procedure.
  • Test Mode (Manual Operation / Manual Defrost)["Press Energy Saver Key + Fridge Key simultaneously for 8 seconds.","All displays on the front…
  • Touch Point CalibrationRefer to section 4-1-9 (page 65) for touch point calibration entry procedure.
  • User Data Backup/Restoration FunctionRefer to section 4-1-10 (page 66) for user data backup/restoration entry procedure.

Full entry steps, exit procedures, and test sequences are available in Max.