1 document33 error codes8 service modes

Available documentation

Service Manual

  • Service Manual RF201A Active Smart USA Refrigerator Freezer87 pg
    Covers this model
MyPros+ Max

Diagnose your Fisher & Paykel 819091A.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (33)

CodeMeaning
1On the last power up, the power module failed self-test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected; heater or wiring…14The low ambient heater is drawing more current than expected; short in the…15The PC fan is drawing less current than expected; wiring is open circuit or the…16The PC fan is drawing more current than expected; wiring is shorted or the fan…17The FC fan is drawing less current than expected; wiring is open circuit or the…18The FC fan is drawing more current than expected; wiring is shorted or the fan…19Reserved.2The previous 2 defrosts were aborted after 40 minutes.20Flapper heater current low.21Flapper heater current is high.22The resistance of the PC sensor 2 is outside the normal range (> 45K Ohms); PC2…23The resistance of the PC sensor 2 is outside the normal range (< 660 Ohms); PC2…24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)…25The resistance of the ice tray sensor is outside normal range (< 660 Ohms)…26Icemaker motor timed out; the icemaker gearbox is not returning to the start…27Icemaker motor current high.28Icemaker solenoid current high.29Icemaker solenoid current low.3The resistance of all the temperature sensors are outside the normal range (>…4The resistance of all the temperature sensors are outside the normal range (<…40Icemaker solenoid Transistor 1 Short Circuit; a transistor on the controller…41Icemaker solenoid transistor 2 Short Circuit.5The resistance of the FC sensor is outside the normal range (> 45K Ohms).6The resistance of the FC sensor is outside the normal range (< 660 Ohms).7The resistance of the Evaporator sensor is outside the normal range (> 45K…8The resistance of the Evaporator sensor is outside the normal range (< 660…
View all 33 error codes

Service modes (8)

  • Data Download ModePress and hold the MENU button, then press the UP button for four seconds, then press the DOWN…
  • Diagnostic ModePress and hold the MENU button, then press the UP button for 4 seconds. The PC temperature will be…
  • Flowmeter CalibrationPress and hold the MEASURED FILL button, then press the DOWN button to enter calibration mode
  • Forced DefrostWhile pressing and holding the MENU button, press the DOWN button for 4 seconds.
  • Forced Icemaker HarvestPress and hold down the MEASURED FILL + UP + DOWN buttons for 4 seconds.
  • Input/Output Status ModePress and hold the MENU button, then press the UP button for 4 seconds to enter Diagnostic mode…
  • Sabbath ModePress and hold MENU + MEASURED FILL + DOWN for 4 seconds.
  • Show Off ModePress and hold MENU + DOWN + UP for 4 seconds.