mypros+
Model reference

KitchenAid KDFE104DBL0

Dishwasher

11 documents78 error codes11 service modes

Available documentation

Service Manual

  • jobaid w10573282120 pg
    Covers this model
  • 2013 Stainless Steel Tall Tub Dishwasher120 pg
    Covers this model

Tech Sheet

  • Tech Sheet - W10580767 - Rev C (FR)16 pg
    Covers this model
  • Tech Sheet12 pg
    Covers this model
  • KDFE104DSS2 Tech Sheet W10751166 Rev C12 pg
    Covers this model

Service Flash

  • Service Pointer - W11782244 - Rev A - Whirlpool, Maytag, KitchenAid, JennAir Dishwashers In-Line Fuse6 pg
    Covers this model
  • Technical Service Pointer - W10841713 (Door Clicking)6 pg
    Covers this model
  • Technical Service Pointer - W11753104 - Stainless Steel Dishwasher Models False F10E5 Error6 pg
    Covers this model

Tech Tip

  • Instruction Sheet2 pg
    Covers this model

Installation Guide

  • Installation Instructions56 pg
    Covers this model
  • Instruction Sheet for Heater Element kit2 pg
    Covers this model
MyPros+ Max

Diagnose your KitchenAid KDFE104DBL0.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (78)

View all 78 error codes
F10E1Dispenser electrical problemF10E2Vent wax motor electrical problemF10E3Drying fan errorF1E1Control detected K400 pilot relay stuck closed.F1E2Damaged or corrupted memory on control board; incompatible software components…F2-E1Control detected stuck key(s) in keypad or keypad connection.F2-E2User interface cannot communicate with main control; loose user interface…F2E1Control detected stuck key(s) in keypad or keypad connection.F2E2User interface cannot communicate with main control; loose user interface…F3-E1Open connector or component in temperature sensing circuit; open or faulty…F3-E2Shorted connection or component in temperature sensing circuit; incoming water…F3-E3OWI failure; failed calibrationF3E1Open connection or component in temperature sensing circuit; open or faulty…F3E2Shorted connection or component in temperature sensing circuit; incoming water…F3E3OWI calibration failure.F4-E3Wash motor not running; loose connection in motor circuit and/or faulty wash…F4E4Wash motor failure due to loose connection in wash motor circuit and/or open…F5-E1Door stuck open; door was not latched within 4 seconds of pressing Start/Resume…F5-E2Door stuck closed; control programmed to not start if it suspects the door…F5E1Door was not latched within 3 seconds of pressing Start/Resume, or loose…F5E2Control suspects door switch is stuck closed; control programmed to not start…F6-E1Low/no water (mechanical problem); no water to dishwasher, water captured by…F6-E2Fill valve electrical problem; loose connection in fill valve circuit and/or…F6-E3Suds/air in pump; too many suds, bowls/pots capturing wash water, water…F6-E4Float switch open; overfill switch stuck in overfill position and/or dishwasher…F6-E7Disconnected or damaged flowmeter.F6-E8Regen valve electrical problem; loose connection in regen valve circuit and/or…F6E1Low or no water (mechanical problem)F6E2Fill valve electrical problemF6E3Suds/air in pumpF6E4Float switch openF6E6Cool waterF7-E1No heat; control programmed to disable heater due to detected water heating…F7-E2Heater stuck on; heater drive circuit on the control is faulty.F7E1No heatF7E2Heater stuck onF8-E1Slow drain; obstructed drain hose or path, or drain pump impeller fractured.F8-E2Drain motor electrical problem; loose connection in drain motor circuit and/or…F8-E3Drain motor stuck on; drain motor drive circuit on the control is faulty.F8E1Slow drainF8E4Drain motor electrical problemF9-E1Diverter can't find position; corroded or loose connection in diverter…F9-E2Diverter stuck on; diverter drive circuit on the control is faulty.F9-E3Control detected diverter disk in sump is missing.F9E1Diverter can't find positionF9E2Diverter stuck onF9E3Diverter disc missingF9E4Lower spray arm error

Service modes (11)

  • Clear Customer Error HistoryDuring Service Diagnostic Cycle Interval 4, press HI TEMP key to clear customer error history.
  • Clear Error HistoryDuring Service Diagnostics Cycle interval where Hi Temp LED is on (interval 22), press Hi Temp key…
  • clear_error_historyDuring diagnostic program interval 22, press Hi Temp key to clear customer error history. If Hi…
  • customer_program_fast_forwardAfter starting a customer program, press HI TEMP
  • diagnostic1
  • Rapid Advance (Customer Cycles)["Start a customer cycle.","Press HIGH TEMP
  • Rapid Advance ModeAfter starting a cycle, press HI TEMP
  • Rapid Advance Mode (Customer Cycles)After starting a customer cycle, press HIGH TEMP
  • Rapid Advance Mode (during normal cycle)Press HI TEMP
  • Service Diagnostic CycleWith dishwasher in standby mode, press any 3 keys in the sequence 1-2-3, 1-2-3, 1-2-3 with no more…
  • Service Diagnostics Cycle["Press Start key to wake up the control panel.","Press any 3 keys in the sequence…

Full entry steps, exit procedures, and test sequences are available in Max.