Model reference

Samsung DW80J9945US/AA

Dishwasher

6 documents40 error codes4 service modes

Available documentation

Service Manual

  • DISHWASHER Service Manual86 pg
    Covers this model
  • Dishwasher Service Manual86 pg
    Covers this model

Bulletin

  • Version 01 Water Wall Dishwasher Service Bulletin3 pg
    Covers this model
  • Water leak from corners of dishwasher3 pg
    Covers this model
  • Fast Track Trouble shooting11 pg
    Covers this model

Training

  • Dishwasher DW-9900H series training76 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung DW80J9945US/AA.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (40)

CodeMeaning
1EHigh pressure switch does not measure high level after water supply completion…3CCirculation pump failure (newer S/W)3ECirculation pump failure4CWater supply failure4C5200 water supply pulses detected during non-water supply mode; cycle continues.4EWater supply failure4E5200 water supply pulses detected during non-water supply mode.5CDrain pump failure (no display during cycle)5C1Drain pump check code occurred 11 times with 5-minute pause and retry; driving…5EDrain pump failure7CVane motor position sensing failure (newer S/W)7EVane motor position sensing failure9C1Blackout or DC link voltage is high or low voltage condition; driving parts…9C2Blackout or DC link voltage is high or low voltage condition; driving parts…9E1Blackout or DC link voltage is high or low voltage condition; switches to stop…9E2Blackout or DC link voltage is high or low voltage condition; switches to stop…ACCommunication failure between main PBA and sub PBA for 24 seconds; cycle…AC6No response received from inverter PBA for 3 seconds; inverter relay off for 2…AECommunication failure between main PBA and sub PBA for 24 seconds (6 seconds in…AE6No response received from inverter PBA for 3 seconds; inverter relay off for 2…bC2Touch button pressed and held for 30 continuous seconds or longer; cycle…bC3IC communications failure between the Sub PBA and touch button; cycle continues.bE2Touch button pressed and held for 30 continuous seconds or longer (no display…bE3IC communications failure between the Sub PBA and touch button (no display…C3Turbidity sensor reference voltage cannot be reached after 10 seconds of…dCDoor is open during test mode operation (newer S/W code designation).dEDoor is open during test mode operation.E3Turbidity sensor reference voltage cannot be reached after 10 seconds of…HCHeater overheatHC1Heater not heating (newer S/W)
View all 40 error codes

Service modes (4)

  • Check Code Recall (S/W Version ~7133)Press Power (make it power on)
  • Service Inspection Mode (SVC Test Mode)Press the Auto, Delicate, and Power buttons at the same time for two seconds to enter Service…
  • SVC Data Display ModeWhen the power is on, press and hold the Auto key and Express key combination for 3 seconds
  • Test Mode (Software Version Check)Press the 'Zone booster L', 'Zone booster R' and 'Power key' at the same time to enter test mode

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax