Model reference
Whirlpool WFE745H0FH1
Range
4 documents35 error codes27 service modes
Available documentation
Tech Sheet
- TechSheet-W10843071-RevA.pdf8 pg
- Wiring Diagram - W10843087 - Rev A2 pg
Service Manual
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
- Technical Manual - Cooking Surface Temperature Limits12 pg
MyPros+ Max
Diagnose your Whirlpool WFE745H0FH1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (35)
CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1-E0EEPROM communication error within the MRC control.F1-E5Sensor out of range detected by MRC control.F1-E7PCB thermistor open or shorted.F1E0Internal board failure (LCC/LCX control).F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2-E0Keypad disconnected from control.F2-E1Stuck key detected on the keypad.F2-E2Cancel key error on the keypad.F2E0Shorted key (LCC/LCX control).F2E1Stuck KeypadF3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer temperature sensor open or shorted.F3E0Oven sensor opened (LCC/LCX control)F3E1Oven sensor shorted (LCC/LCX control).F3E2Bake/Broil range over temperature (LCC/LCX control).F3E3Clean range over temperature (LCC/LCX control).F5-E0Door and door position switch do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and door position switch do not agree during Clean mode (Maxwell/MRC…F5E1Door latch not operating during Clean mode (LCC/LCX control).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6-E1Over temperature condition during cook mode.F6-E2Over temperature condition during clean mode.F6-E3Over temperature condition in warming drawer.F6E0Oven User Interface lost communication between UI and ACU (Indigo control).F6E1Over temperature cookF6E2Over temperature during clean mode (Maxwell/MRC control).Service modes (27)
- Auto Test["Enter Diagnostics mode (CANCEL > CANCEL > START)","Press the up arrow, '+' key, or '3' key to…
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Maxwell/MRC Controls)1
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- CONTROL RESET["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to CONTROL RESET"]
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Mode (Service Mode Entry)["Press CANCEL","Press CANCEL","Press START","Display shows 'TEST ON' with cavity temperature and…
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- DISPLAY["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to DISPLAY"]
- ENG MODE["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to ENG MODE","Press START to…
- FAULTS["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to FAULTS"]
- RELAY USAGE["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to RELAY USAGE"]
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature Adjustment["Press OVEN LIGHT for 5 seconds (current offset or 0° is shown in display)","Press 'More'/'Less'…
- TEST MODE["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to TEST MODE"]
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
- TEST ON (Relay Checks)["Enter Diagnostics mode (CANCEL > CANCEL > START)","At the TEST ON screen, press specific keys to…
- USAGE["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to USAGE using up arrow, '+' key, or…
- VERSION["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to VERSION"]
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
78,000+ service manuals · 160,000+ error codes · 55+ brands