Model reference
Whirlpool YWGI925C0BS0
Range
5 documents55 error codes20 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10575968 - Rev B24 pg
- Fiche technique - Tech Sheet W10587896 - Rev B24 pg
Service Manual
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
Installation Guide
- Installation Instructions20 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Whirlpool YWGI925C0BS0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (55)
CodeMeaning
C-81Over temperature on induction cooktop (Type 2 failure).C-82Over temperature on induction cooktop (Type 2 failure).C-83Temperature sensor stuck on induction cooktop (Type 2 failure).F-12Coil under current on induction cooktopF-21Supply power frequency error on induction cooktopF-25Stuck fan on Induction Power System (IPS), right or left side fan depending on…F-36Temperature sensor is not working on induction cooktop (Type 1 failure).F-37Temperature sensor is not working on induction cooktop (Type 1 failure).F-40Induction Power System (IPS) failureF-42Power supply issue on induction cooktop (Type 2 failure).F-43Under voltage on induction cooktop (Type 2 failure).F-47Power supply from IPC to User Interface is missing, or WIDE communication error…F-56Wrong or invalid configurationF-58Wrong or invalid configuration on induction cooktop (Type 2 failure).F-60User Interface does not workF1EEPROM communication error or internal control failure (Maxwell/MRC control).F1-E0EEPROM communication error (internal oven control failure).F1-E1Upper RTD uncalibrated (internal oven control failure).F1-E2Lower RTD uncalibrated (internal oven control failure).F1-E5Sensor usage out of range (internal oven control failure).F1-E7PCB Thermistor/Sensor open or shorted.F1-E9WIDE Queue full.F1E0Internal board failure (LCC/LCX control).F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2-E0Keypad disconnected from oven control.F2-E1Stuck key on oven control keypad.F2-E2Stuck key on oven control keypad.F2E0Shorted key (LCC/LCX control).View all 55 error codes
F2E1Stuck KeypadF3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Oven sensor opened (LCC/LCX control)F3E1Oven sensor shorted (LCC/LCX control).F3E2Bake/Broil range over temperature (LCC/LCX control).F3E3Clean range over temperature (LCC/LCX control).F5-E0Door and door position switch(es) do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and door position switch do not agree during Clean mode (Maxwell/MRC…F5E1Door latch not operating during Clean mode (LCC/LCX control).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6-E0Lost communications (oven control).F6-E1Over temperature during cook mode (runaway temp).F6-E2Over temperature during clean mode (runaway temp).F6-E3Over temperature in warming drawer (runaway temp).F6E0Oven User Interface lost communication between UI and ACU (Indigo control).F6E1Over temperature cookF6E2Over temperature during clean mode (Maxwell/MRC control).F6E3Over temperature in warming drawer (Maxwell/MRC control).F6E4Oven User Interface UI and ACU state status mismatch (Indigo control).F8E0Cooling fan speed too lowF8E2Cooling fan speed too highF9-E0Product is mis-wired.F9E0Mis-wired house or range (Maxwell/MRC control).
Service modes (20)
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Maxwell/MRC Controls)1
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Mode (Oven - MRC2 Control)Press CANCEL > CANCEL > START on the oven control
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- Faults View / Clear (Oven)1
- Semi Automatic Test Mode (Oven)1. Enter Diagnostics Mode by pressing CANCEL>CANCEL>START. 2. Press TEMP/TIME '+' or '-' keypads…
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature Calibration (Oven)1
- Test Mode (Oven - Manual Relay Activation)1
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass