mypros+
Model reference

Whirlpool WFW8410SW0

Washer

9 documents73 error codes10 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10071730 - Rev B_W1007173016 pg
    Covers this model
  • Whirlpool Washer Tech Sheet WFW8410SW02 W1007173016 pg
    Covers this model
  • Whirlpool Washer WFW8410SW01 Tech Sheet16 pg
    Covers this model
  • Technical Service Sheet W10207732 Rev B16 pg
    Covers this model
  • Whirlpool Duet Sport Tech Sheet W10207732 WFW8300SW0416 pg
    Covers this model

Service Manual

  • TECHNICAL EDUCATION JOB AID 8178686 ML-8 FRONT-LOADING WASHER EPIC z™96 pg
    Covers this model

Bulletin

  • Service Pointer - 81787722 pg
    Covers this model

Tech Tip

  • Instruction Sheet2 pg
    Covers this model

Other

  • Service Pointer - 8178722 (Excessive Shaking)_81787221 pg
    Covers this model
MyPros+ Max

Diagnose your Whirlpool WFW8410SW0.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (73)

View all 73 error codes
F40Serial communication errorF41Door unlock errorF42Load detected in drum at start of CLEAN WASHER cycle (detection by weight).F43MCU thermal trip errorF44Pump connection lost during drain cycleF5Pump driver fails to activate, one of the main relays is not working properly…F5 E2Door lock errorF5 E3Door unlock errorF52Load detected in drum at start of CLEAN WASHER cycle (detection by weight).F53Drain pump connection lost during the drain cycle between pump and CCU.F5E1Door switch errorF5E2Door lock errorF5E3Door unlock errorF6 E2Door switch errorF6E1Dispenser system errorF7 E0Serial communication error between the Central Control Unit (CCU) and the Motor…F7 E1Motor speed sensing errorF7 E5Overflow conditionF7 E6Motor Control Unit (MCU) overheated; MCU signals the CCU which then resets the…F7E1Motor speed sensing errorF7E5Overflow conditionF8No water detected entering machine or pressure switch trip not detected…F8 E3Dispenser system errorF8 E4Load detected in drum at start of Clean Washer cycle (detected by weight).F9 E1Water temperature sensor (NTC) value is out of range (23°F to 217°F / -5°C to…F9 E2Drain pump connection lost during the drain cycle.F9E1Water heating element failureF9E2Pump drive system errorHEATER ERRORIf the temperature increase during the first 40 minutes is less than 86°F…LOAD DETECTED IN CLEAN WASHER CYCLEA load is detected in the drum at the start of the CLEANING WASHER cycle…LONG DRAINIf the drain time exceeds 8 minutes the water valves turn off.MCU THERMAL PROTECTIONThe MCU has an internal overheat condition and sends a signal to the CCU, then…MOTOR CONTROL UNIT ERRORThe Motor Control Unit has internal failure; if failure occurs during…MOTOR SPEED ERRORIf the control is unable to properly detect motor speed, the machine shuts…NO WATER DETECTEDThe pressure switch is not tripped after 6 minutes; water level is not reached…OVERFLOW CONDITIONIf there is too much water or foam in the machine the overflow contact on the…PUMP DRIVE SYSTEM ERRORWhen the connection between pump and the Central Control Unit (CCU) is lost…rLLoad inside drum during cleaning washer cycleSdSuds lockSERIAL COMMUNICATION ERRORThe communication between the Central Control Unit (CCU) and the User Interface…SudSuds lockSUDS LOCKOverdose of detergent detected during the wash cycle; if suds are detected…WATER TEMPERATURE SENSOR ERRORIf the water temperature sensor (NTC) value is out of range (23°F to 217°F /…

Service modes (10)

  • Manual Diagnostic Test["Washer must be empty and control must be in the OFF state.","Close the door.","Select any one key…
  • Quick Diagnostic Test (Bypass Service History)["Ensure washer drum is empty.","Close the door.","Push POWER.","Select the CLEAN WASHER…
  • Quick Diagnostic Test (bypasses error history)1
  • Quick Diagnostic Test (Bypassing Service History Mode)["Execute with an empty drum.","Close the door.","Push POWER.","Select the CLEAN WASHER…
  • Quick Diagnostic Test (Bypassing Service History)["Ensure drum is empty.","Close the door.","Push POWER.","Select the CLEAN WASHER cycle.","Press…
  • Quick Entry Diagnostic Test (bypasses error history)1
  • Quick Entry Diagnostic Test (bypassing Service History Mode)["Drum must be empty.","Close the door.","Push POWER.","Select the CLEAN WASHER cycle.","Press…
  • Quick Entry Diagnostic Test (bypassing Service History)1
  • Service History Mode & Diagnostic Test["Washer must be empty and control must be in the OFF state.","Close the door.","Select any one key…
  • Service History Mode & Diagnostic Test (Universal Entry)["Washer must be empty and control must be in OFF state.","Close the door.","Select any one key…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass