mypros+
Model reference

Wolf ICBDF364C

Range

3 documents88 error codes6 service modes

Available documentation

Service Manual

  • Wolf Legacy DF Ranges: All Serials — Service Manual88 pg
    Covers this model

Parts Manual

  • Wolf ICB Legacy Dual Fuel Range Enhancement: After Serial 17312500 — Parts Manual59 pg
    Covers this model
  • Wolf ICB Legacy Dual Fuel Range: Prior to Serial 17312499 — Parts Manual43 pg
    Covers this model
MyPros+ Max

Diagnose your Wolf ICBDF364C.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (88)

View all 88 error codes
07-07Right Convection Fan triac shorted.07-08Cooling Fan triac shorted.07-09Oven Light relay shorted.07-10DLB1 shorted.07-11DLB2 shorted.07-12Aux DLB shorted.07-13Inner Bake relay open.07-14Outer Bake relay open.07-15Broil relay open.07-16Left Convection relay open.07-17Right Convection relay open.07-18MDL relay open.07-19Left Convection Fan triac open.07-20Right Convection Fan triac open.07-21Cooling Fan triac open.07-22Oven Light relay open.07-23DLB1 relay or TCO open.07-24DLB2 relay open.07-25Aux DLB open.07-26RTD Circuitry error.07-27RM EE checksum error.07-28HIV SPI communication error detected by RM control.07-29HIV SPI communication error detected by HV-micro.07-30HIV micro feedback error.07-31RM LOV fuse error.07-32RM HIV fuse error.07-33HSWD active, should be inactive.07-34HSWD inactive, should be active.07-35RM Ambient Thermistor open error.07-36RM Ambient Thermistor shorted error.07-37RM Line Voltage A/D error.07-38MDL circuitry error.07-39RM FMEA circuitry error.08EEPROM checksum is incorrect, checked at power up.08-00Keypad circuit error.08-01Keypad communications error detected by the UIM.08-02Keypad communications error detected by the Keypad.08-03Keypad FMEA error.08-04Keypad EE CRC error.08-05Keypad mains sync error.09Meat probe being sensed as shorted.09-00UIM EE checksum error.09-01UIM configuration data CRC error.09-02UIM fuse error.09-03UIM ambient thermistor open error.09-04UIM ambient thermistor shorted error.09-05LCD module error.0BAnalog to Digital error during calibration phase.0CCommunication lost with oven controller.0EPower relay shorted, sensed as closed when should be open10-00Communications error detected by the UIM.10-01Communications error detected by the RM (Relay Module).11-00Overtemp error11-01Overtemp error12-00RM Ambient overtemp error.13-00UIM Ambient overtemp error.14-00Self-clean rate-of-rise error.15-00LPM (Low Power Module) error.

Service modes (6)

  • Diagnostic Mode1
  • Element Testing (within Diagnostic Mode)1. Enter Diagnostic Mode. 2. Turn the oven control knob bezel to the appropriate cooking mode…
  • Fan and Motor Testing (within Diagnostic Mode)1. Enter Diagnostic Mode. 2. Turn oven control knob bezel or press key on ECH to activate specific…
  • Probe Testing (within Diagnostic Mode)1
  • RTD Testing (within Diagnostic Mode)1
  • Three Field Option Modes1. Press and hold CLOCK key for 5 seconds. 2. To change 12hr/24hr clock

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass