Model reference
Wolf ICBDF486G-LP
Range
3 documents88 error codes6 service modes
Available documentation
Service Manual
- Wolf Legacy DF Ranges: All Serials — Service Manual88 pg
Parts Manual
- Wolf ICB Legacy Dual Fuel Range Enhancement: After Serial 17312500 — Parts Manual59 pg
- Wolf ICB Legacy Dual Fuel Range: Prior to Serial 17312499 — Parts Manual43 pg
MyPros+ Max
Diagnose your Wolf ICBDF486G-LP.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (88)
CodeMeaning
01Door Lock or Unlock Switches not sensed within 60 seconds while driving the…01-00RTD Open01-01RTD Shorted02Over temperature occurs when the oven reaches a temperature of 630°F for an…02-00Meat Probe Short03Open circuit detected on RTD Oven Sensor.03-00No Inner Bake element detected.03-01No Outer Bake element detected.03-02No Broil element detected.03-03No Left Convection element detected.03-04No Right Convection element detected.03-05No MDL (Motor Door Lock) detected.03-06No Left Convection Fan detected.03-07No Right Convection Fan detected.03-08No Cooling Fan detected.03-09No Oven Light detected.04Shorted circuit detected on the RTD Sensor.04-00Lock inputs invalid.04-01Lock/Door inputs invalid for Clean.04-02MDL run timeout.05-00TCO (Thermal Cutoff) detected as open.06-00Brownout error.07SPI Communication lost from ECH to the Control Board as reported by Control…07-00Inner Bake relay shorted.07-01Outer Bake relay shorted.07-02Broil relay shorted.07-03Left Convection relay shorted.07-04Right Convection relay shorted.07-05MDL relay shorted.07-06Left Convection Fan triac shorted.View all 88 error codes
07-07Right Convection Fan triac shorted.07-08Cooling Fan triac shorted.07-09Oven Light relay shorted.07-10DLB1 shorted.07-11DLB2 shorted.07-12Aux DLB shorted.07-13Inner Bake relay open.07-14Outer Bake relay open.07-15Broil relay open.07-16Left Convection relay open.07-17Right Convection relay open.07-18MDL relay open.07-19Left Convection Fan triac open.07-20Right Convection Fan triac open.07-21Cooling Fan triac open.07-22Oven Light relay open.07-23DLB1 relay or TCO open.07-24DLB2 relay open.07-25Aux DLB open.07-26RTD Circuitry error.07-27RM EE checksum error.07-28HIV SPI communication error detected by RM control.07-29HIV SPI communication error detected by HV-micro.07-30HIV micro feedback error.07-31RM LOV fuse error.07-32RM HIV fuse error.07-33HSWD active, should be inactive.07-34HSWD inactive, should be active.07-35RM Ambient Thermistor open error.07-36RM Ambient Thermistor shorted error.07-37RM Line Voltage A/D error.07-38MDL circuitry error.07-39RM FMEA circuitry error.08EEPROM checksum is incorrect, checked at power up.08-00Keypad circuit error.08-01Keypad communications error detected by the UIM.08-02Keypad communications error detected by the Keypad.08-03Keypad FMEA error.08-04Keypad EE CRC error.08-05Keypad mains sync error.09Meat probe being sensed as shorted.09-00UIM EE checksum error.09-01UIM configuration data CRC error.09-02UIM fuse error.09-03UIM ambient thermistor open error.09-04UIM ambient thermistor shorted error.09-05LCD module error.0BAnalog to Digital error during calibration phase.0CCommunication lost with oven controller.0EPower relay shorted, sensed as closed when should be open10-00Communications error detected by the UIM.10-01Communications error detected by the RM (Relay Module).11-00Overtemp error11-01Overtemp error12-00RM Ambient overtemp error.13-00UIM Ambient overtemp error.14-00Self-clean rate-of-rise error.15-00LPM (Low Power Module) error.
Service modes (6)
- Diagnostic Mode1
- Element Testing (within Diagnostic Mode)1. Enter Diagnostic Mode. 2. Turn the oven control knob bezel to the appropriate cooking mode…
- Fan and Motor Testing (within Diagnostic Mode)1. Enter Diagnostic Mode. 2. Turn oven control knob bezel or press key on ECH to activate specific…
- Probe Testing (within Diagnostic Mode)1
- RTD Testing (within Diagnostic Mode)1
- Three Field Option Modes1. Press and hold CLOCK key for 5 seconds. 2. To change 12hr/24hr clock
Full entry steps, exit procedures, and test sequences are available in Max.
Related Wolf range models
78,000+ service manuals · 160,000+ error codes · 55+ brands