Model reference
Fisher & Paykel RF195ADUX1
Refrigerator
1 document36 error codes7 service modes
Available documentation
Service Manual
- Service Manual Active Smart® Refrigerator/Freezer102 pg
MyPros+ Max
Diagnose your Fisher & Paykel RF195ADUX1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (36)
CodeMeaning
1On the last power up, the power module failed self test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected; either the heater…14The low ambient heater is drawing more current than expected; either there is a…15The PC fan is drawing less current than expected; either the wiring is open…16The PC fan is drawing more current than expected; either the wiring is shorted…17The FC fan is drawing less current than expected; either the wiring is open…18The FC fan is drawing more current than expected; either the wiring is shorted…2The previous 2 defrosts were aborted after 40 minutes.20The flapper heater current is low.21The flapper heater current is high.22The resistance of the PC sensor 2 is outside the normal range (> 45K Ohms)…23The resistance of the PC sensor 2 is outside the normal range (< 660 Ohms); PC2…24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)…25The resistance of the ice tray sensor is outside normal range (< 660 Ohms)…26The icemaker motor timed out; the icemaker gearbox is not returning to the…27The icemaker motor current is high.28The icemaker solenoid current is high.29The icemaker solenoid current is low.3The resistance of all the temperature sensors are outside the normal range (>…4The resistance of all the temperature sensors are outside the normal range (<…40Icemaker solenoid transistor 1 short circuit; a transistor on the controller…41Icemaker solenoid transistor 2 short circuit.42The icemaker fill tube nozzle heater current is high (only seen with data…43The icemaker fill tube nozzle heater current is low / element open circuit…44The PC return duct heater current is too high (only seen with data download…45The PC return duct heater current is too low (only seen with data download…5The resistance of the FC sensor is outside the normal range (> 45K Ohms).View all 36 error codes
6The resistance of the FC sensor is outside the normal range (< 660 Ohms).7The resistance of the Evaporator sensor is outside the normal range (> 45K…8The resistance of the Evaporator sensor is outside the normal range (< 660…9The resistance of the PC sensor is outside the normal range (> 45K Ohms).F30No display signal received (shorted or broken wire).F31No display signal received (shorted or broken wire) clock or data line.
Service modes (7)
- Data Download ModePress and hold the MENU key, then press the UP key for four seconds (enters diagnostic mode), then…
- Diagnostic ModePress and hold the MENU key, then press the UP key for 4 seconds. The PC sensor temperature will be…
- Filter Alarm DisablePress and hold MENU + UP + LOCK keys for 4 seconds.
- Forced DefrostWhile pressing and holding the MENU key, press the DOWN key for 4 seconds.
- Forced Icemaker HarvestPress the DOWN, UP and LOCK buttons together and hold for 4 seconds.
- Sabbath ModePress LOCK + MENU + DOWN keys together and hold for 4 seconds.
- Show Off ModePress MENU + DOWN + UP keys together and hold for 4 seconds.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Fisher & Paykel refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands