Model reference
Fisher & Paykel RF522WLDUX6
Refrigerator
1 document50 error codes8 service modes
Available documentation
Service Manual
- ActiveSmart™ Refrigerator Service Manual - Version 4, 5 & 6 models74 pg
MyPros+ Max
Diagnose your Fisher & Paykel RF522WLDUX6.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (50)
CodeMeaning
1On the last power up, the control module failed self test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected; either the heater…14The low ambient heater is drawing more current than expected; either there is a…15The PC fan is drawing less current than expected; either the wiring is open…16The PC fan is drawing more current than expected; either the wiring is shorted…17The FC fan is drawing less current than expected; either the wiring is open…18The FC fan is drawing more current than expected; either the wiring is shorted…2The PC temperature has not changed in the expected time period, either too warm…20The flapper heater current is low.21The flapper heater current is high.22The resistance of the water tank (PC2) sensor is outside the normal range (>…23The resistance of the water tank (PC2) sensor is outside the normal range (<…24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)25The resistance of the ice tray sensor is outside the normal range (< 660 Ohms)26The icemaker motor has timed out; the icemaker gearbox is not returning to the…27The icemaker motor current is high28The icemaker solenoid is drawing more current than expected; either there is a…29The icemaker solenoid is drawing less current than expected; either the wiring…30Display harness fault31Display harness fault40Icemaker solenoid transistor 1 short circuit.41Icemaker solenoid transistor 2 short circuit.42Icemaker fill tube heater short circuit43Icemaker fill tube heater open circuit9The resistance of the PC sensor is outside the normal range (> 45K Ohms).EMB-2Embraco inverterEMB-3Embraco inverterView all 50 error codes
EMB-4Embraco inverterEMB-5Embraco inverterINV-1F&P Inverter module error.INV-10F&P Inverter module error.INV-11Compressor starts and stops.INV-12Compressor starts and stops.INV-13Over current detected.INV-14Communication error between control module and inverter.INV-15AC input voltage is low.INV-16F&P Inverter module error.INV-17Motor bridge temperature above 100C (212F).INV-18Inverter PCB over temperature.INV-2F&P Inverter module error.INV-3F&P Inverter module error.INV-4F&P Inverter module error.INV-5F&P Inverter module error.INV-6F&P Inverter module error.INV-7F&P Inverter module error.INV-8Compressor cannot start after 6 attempts.INV-9F&P Inverter module error.
Service modes (8)
- Diagnostic ModePress and hold the COMPARTMENT and WARMER buttons together for 4 seconds
- Disable Water Filter WarningPress the COMPARTMENT, ALARM MUTE, and WARMER buttons together for 4 seconds.
- Forced Defrost ModePress the COMPARTMENT and COLDER buttons together for 4 seconds.
- Forced Ice Harvest ModePress the ALARM MUTE, COLDER, and WARMER buttons together for 4 seconds, then close the PC door.
- Optical Download ModeEnter diagnostic mode (COMPARTMENT + WARMER for 4 seconds), then press the COLDER button
- Reset Water Filter IconPress the ALARM MUTE and WARMER buttons together for 4 seconds.
- Sabbath ModePress the COMPARTMENT, ALARM MUTE, and COLDER buttons together for 10 seconds.
- Showroom ModePress the COMPARTMENT, WARMER, and COLDER buttons together until a long beep is heard.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Fisher & Paykel refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass