Model reference
Fisher & Paykel RS36A80U1
Refrigerator
1 document53 error codes8 service modes
Available documentation
Service Manual
- SERVICE MANUAL ActiveSmart™ Slide-in refrigerator RS90 and RS36 models74 pg
MyPros+ Max
Diagnose your Fisher & Paykel RS36A80U1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (53)
CodeMeaning
1On the last power up, the control module failed self test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected; either the heater…14The low ambient heater is drawing more current than expected; either there is a…15The PC fan is drawing less current than expected; either the wiring is open…16The PC fan is drawing more current than expected; either the wiring is shorted…17The FC fan is drawing less current than expected; either the wiring is open…18The FC fan is drawing more current than expected; either the wiring is shorted…2The previous 2 defrosts were aborted after 40 minutes.20The flapper heater current is low21The flapper heater current is high22The resistance of the water tank (PC2) sensor is outside the normal range (>…23The resistance of the water tank (PC2) sensor is outside the normal range (<…24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)25The resistance of the ice tray sensor is outside the normal range (< 660 Ohms)26The icemaker motor has timed out; the icemaker gearbox is not returning to the…27The icemaker motor current is high28The icemaker solenoid is drawing more current than expected; either there is a…29The icemaker solenoid is drawing less current than expected; either the wiring…3The resistance of all the temperature sensors are outside the normal range (>…30Display harness fault31Display harness fault4The resistance of all the temperature sensors are outside the normal range (<…40Icemaker solenoid transistor 1 short circuit.41Icemaker solenoid transistor 2 short circuit.42Icemaker fill tube heater short circuit43Icemaker fill tube heater open circuit49Communication error between control module and inverter.View all 53 error codes
5The resistance of the FC sensor is outside the normal range (> 45K Ohms).6The resistance of the FC sensor is outside the normal range (< 660 Ohms).7The resistance of the evaporator sensor is outside the normal range (> 45K…8The resistance of the evaporator sensor is outside the normal range (< 660…9The resistance of the PC sensor is outside the normal range (> 45K Ohms).INV-1Inverter module error (LED flashes 1 time on inverter).INV-10Inverter module error (LED flashes 10 times on inverter).INV-11Compressor starts and stops.INV-12Compressor starts and stops.INV-13Over current detected.INV-14Communication error between control module and inverter.INV-15AC input voltage is low.INV-16Inverter module error (LED flashes 16 times on inverter).INV-17Motor bridge temperature above 100°C (212°F).INV-18Inverter PCB over temp.INV-2Inverter module error (LED flashes 2 times on inverter).INV-3Inverter module error (LED flashes 3 times on inverter).INV-4Inverter module error (LED flashes 4 times on inverter).INV-5Inverter module error (LED flashes 5 times on inverter).INV-6Inverter module error (LED flashes 6 times on inverter).INV-7Inverter module error (LED flashes 7 times on inverter).INV-8Compressor cannot start after 6 attempts.INV-9Inverter module error (LED flashes 9 times on inverter).
Service modes (8)
- Diagnostic ModePress and hold the COMPARTMENT and WARMER buttons together for 4 seconds
- Disable Water Filter WarningPress the COMPARTMENT, ALARM MUTE, and WARMER buttons together for 4 seconds.
- Forced Defrost ModePress the COMPARTMENT and COLDER buttons together for 4 seconds.
- Forced Ice Harvest ModePress the ALARM MUTE, COLDER, and WARMER buttons together for 4 seconds, then close the PC door.
- Optical Download ModeEnter diagnostic mode (COMPARTMENT + WARMER for 4 seconds), then press the COLDER button
- Reset Water Filter IconPress the ALARM MUTE and WARMER buttons together for 4 seconds.
- Sabbath ModePress the COMPARTMENT, ALARM MUTE, and COLDER buttons together for 10 seconds.
- Showroom ModePress the COMPARTMENT, WARMER, and COLDER buttons together until a long beep is heard.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Fisher & Paykel refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass