Model reference
LG PRHR023A
Air Conditioner
2 documents50 error codes11 service modes
Available documentation
Service Manual
- Heat Recovery Unit SERVICE MANUAL (Exploded View)26 pg
- Air Conditioner Service Manual (R410A)147 pg
MyPros+ Max
Diagnose your LG PRHR023A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (50)
CodeMeaning
01Air temperature sensor of indoor unit is open or short.02Inlet pipe temperature sensor of indoor unit is open or short.03Communication error between wired remote controller and indoor unit04Malfunction of drain pump.05Communication error between outdoor unit and indoor unit06Outlet pipe temperature sensor of indoor unit is open or short.09Indoor EEPROM error10Poor fan motor operation113Outdoor unit liquid pipe (condenser) temperature sensor error115Outdoor unit subcooling outlet temperature sensor error150Outdoor unit discharge superheat low151Failure of operation mode conversion at outdoor unit2001Pipe detection error (HR unit)201C#HRHR unit liquid pipe temperature sensor error202C#HRHR unit sub-cooling inlet pipe temperature sensor error203C#HRHR unit sub-cooling discharge pipe temperature sensor error204C#HRCommunication error between the HR unit and outdoor unit205C#HR4 series upgraded 485 communication error between HR unit and HR unit modem.206C#HRDuplicate address error of HR unit207C#HRCommunication error between Master and Slave Main PCB of HR Unit.208C#HRCommunication error of EEPROM of HR Unit21Outdoor unit inverter compressor IPM fault22Inverter board input over current (RMS) of outdoor unit23Outdoor unit inverter compressor DC link low voltage24Outdoor unit high pressure switch25Outdoor unit input voltage high/low26Outdoor unit inverter compressor start failure29Outdoor unit inverter compressor over current32Outdoor unit inverter compressor 1 high discharge temperature.34High pressure of outdoor unitView all 50 error codes
35Low pressure of outdoor unit36Outdoor unit low compression ratio limited.40Outdoor unit inverter compressor CT sensor fault41Outdoor unit inverter compressor discharge temperature sensor fault42Outdoor unit low pressure sensor fault43Outdoor unit high pressure sensor fault44Outdoor unit air temperature sensor fault45Outdoor unit heat exchanger temperature sensor (front side) fault46Outdoor unit suction temperature sensor fault50Omitting connection of R, S, T power of outdoor unit.51Excessive capacity of indoor units52Communication error: inverter PCB to Main PCB53Communication error: indoor unit to Main PCB of outdoor unit57Communication error: Main PCB to inverter PCB60Inverter PCB EEPROM error of outdoor unit62Outdoor unit inverter heatsink high temperature65Outdoor unit inverter heatsink temperature sensor fault67Outdoor unit fan lock71Converter CT sensor error of outdoor unit.86Outdoor unit Main PCB EEPROM error
Service modes (11)
- Auto Addressing["Wait 3 minutes after supplying power to all master/slave outdoor units and indoor units","Press…
- Auto Pipe Detection["After auto addressing is complete, turn on Master unit PCB DIP switch No.5","Select mode using…
- Cool & Heat Selector (Heat Pump Only)["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
- Cycle Data View["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
- Heat Pump / Heat Recovery System Setting["Turn on DIP switch No.4","Factory setting display 'HR' appears","Change 'HR' to 'HP' display by…
- Night Low Noise Function["Turn on Service PCB DIP switch No.5","Select mode using forward/backward buttons to 'Func'","Push…
- Pump Down["Power reset after Master Unit DIP switch setting","Set all IDU to cooling operation","Press the…
- Refrigerant Noise Reduction Mode["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
- Snow Removal & Rapid Defrost["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
- Static Pressure Compensation Mode["Turn on Service PCB DIP switch No.5","Select mode using forward/backward buttons to 'Func'","Push…
- Vacuum Mode["Turn on Service PCB DIP switch No.5","Select mode using forward/backward buttons to 'SVC'","Push…
Full entry steps, exit procedures, and test sequences are available in Max.