mypros+
Model reference

LG PRHR043A

Air Conditioner

2 documents50 error codes11 service modes

Available documentation

Service Manual

  • Heat Recovery Unit SERVICE MANUAL (Exploded View)26 pg
    Covers this model
  • Air Conditioner Service Manual (R410A)147 pg
    Covers this model
MyPros+ Max

Diagnose your LG PRHR043A.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (50)

CodeMeaning
01Air temperature sensor of indoor unit is open or short.02Inlet pipe temperature sensor of indoor unit is open or short.03Communication error between wired remote controller and indoor unit04Malfunction of drain pump.05Communication error between outdoor unit and indoor unit06Outlet pipe temperature sensor of indoor unit is open or short.09Indoor EEPROM error10Poor fan motor operation113Outdoor unit liquid pipe (condenser) temperature sensor error115Outdoor unit subcooling outlet temperature sensor error150Outdoor unit discharge superheat low151Failure of operation mode conversion at outdoor unit2001Pipe detection error (HR unit)201C#HRHR unit liquid pipe temperature sensor error202C#HRHR unit sub-cooling inlet pipe temperature sensor error203C#HRHR unit sub-cooling discharge pipe temperature sensor error204C#HRCommunication error between the HR unit and outdoor unit205C#HR4 series upgraded 485 communication error between HR unit and HR unit modem.206C#HRDuplicate address error of HR unit207C#HRCommunication error between Master and Slave Main PCB of HR Unit.208C#HRCommunication error of EEPROM of HR Unit21Outdoor unit inverter compressor IPM fault22Inverter board input over current (RMS) of outdoor unit23Outdoor unit inverter compressor DC link low voltage24Outdoor unit high pressure switch25Outdoor unit input voltage high/low26Outdoor unit inverter compressor start failure29Outdoor unit inverter compressor over current32Outdoor unit inverter compressor 1 high discharge temperature.34High pressure of outdoor unit
View all 50 error codes

Service modes (11)

  • Auto Addressing["Wait 3 minutes after supplying power to all master/slave outdoor units and indoor units","Press…
  • Auto Pipe Detection["After auto addressing is complete, turn on Master unit PCB DIP switch No.5","Select mode using…
  • Cool & Heat Selector (Heat Pump Only)["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
  • Cycle Data View["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
  • Heat Pump / Heat Recovery System Setting["Turn on DIP switch No.4","Factory setting display 'HR' appears","Change 'HR' to 'HP' display by…
  • Night Low Noise Function["Turn on Service PCB DIP switch No.5","Select mode using forward/backward buttons to 'Func'","Push…
  • Pump Down["Power reset after Master Unit DIP switch setting","Set all IDU to cooling operation","Press the…
  • Refrigerant Noise Reduction Mode["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
  • Snow Removal & Rapid Defrost["Turn on Master unit PCB DIP switch No.5","Select mode using forward/backward buttons to…
  • Static Pressure Compensation Mode["Turn on Service PCB DIP switch No.5","Select mode using forward/backward buttons to 'Func'","Push…
  • Vacuum Mode["Turn on Service PCB DIP switch No.5","Select mode using forward/backward buttons to 'SVC'","Push…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass