Kenmore Dryer Error Code F-50

No voltage detected at the water valve relay (only appears in diagnostic test mode, steam model only).

No voltage detected at the water valve relay (only appears in diagnostic test mode, steam model only).

First step from the service manual

Check that the wires are plugged in on the valve and at the relay on the electronic control. See TEST #8, page 12.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for F-50.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What F-50 means on a Kenmore dryer

The F-50 error code on a Kenmore steam dryer indicates that the electronic control board detected no voltage at the water valve relay during diagnostic test mode. This code is exclusive to steam-model dryers and will only appear when the unit is being run through its built-in diagnostic sequence, not during normal operation. The water valve relay is a switching component on the electronic control board that supplies power to the water inlet valve, which is responsible for introducing water into the drum during steam cycles.

When the control board activates the relay and monitors for a voltage response, a failure to detect that voltage signals either a wiring fault or a component failure somewhere in that circuit. The most common entry point for diagnosis is the physical wiring connections: the harness connector at the water valve itself and the corresponding connector at the relay on the control board. Loose, corroded, or fully disconnected terminals account for a large share of F-50 faults before any component replacement is needed.

If the wiring connections check out and are properly seated, the fault may lie with the water valve itself, the relay on the control board, or the wiring harness running between them. The diagnostic procedure directs technicians to TEST #8 for a structured approach to isolating the failure. Because the code only surfaces in diagnostic mode, it is important to confirm whether steam functions were actually malfunctioning before the test, which helps narrow down whether the issue is a hard failure or an intermittent connection problem.

Source: manufacturer service documentation.

Common causes of F-50

  1. 01

    Disconnected or loose wiring at the water valve

    Wiring / connection

    The wire harness connector at the water inlet valve may have come loose or pulled off entirely. Inspect the valve connector and firmly reseat it to see if the fault clears on the next diagnostic run.

  2. 02

    Disconnected or loose wiring at the control board relay

    Wiring / connection

    The connector on the electronic control board that feeds the water valve relay may be unseated. Check that the corresponding harness plug is fully clicked into place on the board.

  3. 03

    Damaged or broken wiring harness

    Part replacement

    The wiring between the water valve and the relay on the control board may have a broken wire, chafed insulation causing a short, or a corroded terminal. Visually inspect the full length of the harness and check for continuity.

  4. 04

    Faulty water inlet valve

    Part replacement

    If the valve's internal solenoid coil has failed open, the circuit will not complete and voltage will not be detected as expected. The valve can be tested for proper resistance across its terminals.

  5. 05

    Failed electronic control board relay

    Part replacement

    If the relay on the control board itself has failed, it will not switch properly and voltage will not be present at the valve circuit. This is typically diagnosed after all wiring and the valve have been confirmed to be in good condition.

See the test procedure for each cause

Frequently asked questions about F-50

What does F-50 mean on a Kenmore dryer?
F-50 means the electronic control board detected no voltage at the water valve relay during a diagnostic test cycle. This code only appears on steam-model Kenmore dryers and only shows up in diagnostic mode, not during regular drying. It points to a fault in the circuit between the control board and the water inlet valve, which could be a loose connection, damaged wiring, or a failed component.
How do I fix an F-50 error on my Kenmore steam dryer?
Start by checking the wire connections at the water inlet valve and at the relay on the electronic control board, as loose connectors are the most common cause. Firmly reseat any connectors that are not fully engaged, then re-run the diagnostic test to see if the code returns. If the connections are secure and the code persists, the wiring harness and water valve should be tested for continuity and proper resistance before considering control board replacement.
Is it safe to use my dryer if it shows an F-50 error?
The F-50 code only appears in diagnostic test mode and relates specifically to the steam function of the dryer. If the steam feature is not working but standard drying cycles operate normally, the dryer can generally continue to be used for non-steam drying while you arrange for a repair. However, if you notice any other unusual behavior such as water leaks or electrical issues, stop using the unit until it has been inspected.
Will resetting my Kenmore dryer clear the F-50 error?
Resetting the dryer by unplugging it for a few minutes may temporarily clear the code, but the fault will return when the diagnostic test is run again if the underlying wiring or component issue has not been resolved. A proper fix requires tracing and correcting the fault in the water valve circuit rather than relying on a reset.
How much does it cost to repair a Kenmore dryer with an F-50 error?
Repair costs vary depending on the root cause. If the fix is simply reseating a loose connector, there may be no parts cost at all, though a service call fee for a technician typically ranges from around $75 to $150. Replacing a water inlet valve generally costs between $25 and $75 for the part, while a new electronic control board can range from $100 to $250 or more, plus labor if a technician is doing the work.