mypros+

Samsung Dryer Error Codes

76 error codes for Samsung dryer models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any Samsung dryer error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

3CA8BLDC motor fault detected by compressor inverter.5COverflow detected three times in succession or drain pump does not work.9C1Power condition fault9C2Power condition fault9CA1Power condition fault detected by compressor inverter.9CA2Power condition fault detected by compressor inverter.9EInvalid power source frequency.9E1Electronic control problem (over voltage error).ACElectronic Control ProblemAC4Communication error between WIFI PBA and MAIN PBA.AC6Signals between the main and inverter PBAs are not sensed; incorrect wire…ACACommunication error between main and compressor inverter PBA (compressor…AEElectronic control communication error between PCBs.AE3DR Ready Modem wire test failure.bC2Button Stuck ErrorbEUnit detects a button is being pressed for over 30 seconds or button is stuck…bE2Button errorC1Unit is detecting items inside the drum or there is an error on the dry sensor.C8About 80% of the vent is clogged.C80About 80% of the vent is cloggedC9Over 90% of the vent is clogged.C90Over 90% of the vent is clogged, which may lead to poor drying performance or…CAElectronic control problem (invalid communication).ClgThe vent is clogged.CtThe internal temperature of the dryer is too low (below 32°F) or too high (over…dCDoor Detection ErrordEDoor errordFInvalid state of the door sensor circuit; loose or open wire terminals at the…dORunning the dryer with the door open; invalid state for more than 0.25 seconds.dO dEDoor openE1Thermistor or thermistor circuit shortE3Motor or motor circuit open.EEInvalid state of EEPROM communication.EEEInvalid state of EEPROM communication.EEpromEEPROM failEEprom FailInvalid state of EEPROM communication.EHHeating errorEtCheck the heater thermistor; for gas models, check that gas is supplied…FCInvalid power source frequency detected by the electronic control.FEPower source frequency errorHCInvalid Heating Temperature (Over Heating)HC5Compressor stop accumulated three times due to high temperature detected with…hEInvalid heating temperature detected; heater thermistor malfunction or gas…odInvalid dry time in excess of allowed dry time, possibly due to sensor bar open…OEElectronic control problem / over voltage error.tCThermistor 1 resistance is very low or very high, indicating a faulty cycling…TC2The thermistor resistance is very low or high.tC4Drum IPM temperature sensor issue (very low or high).tC5Thermistor 2 resistance is very low or very high, indicating a faulty vent…tC7Thermistor 3 resistance is very low or high.tC8Thermistor 4 resistance is very low or high.tC9Compressor IPM temperature sensor issue (very low or high).tCAThermistor 5 resistance is very low or high.tEInvalid heating temperature detected, possibly caused by clogged lint screen or…tOThe thermistor resistance is very low or high (alternate display for thermistor…tSThe thermistor resistance is very low or high, indicating a possible clogged…

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started