CodeDescription
Blinking HFixed coil temperature error.C-81Over temperature condition detectedC-82Over temperature condition detectedC-83Temperature sensor stuck on induction cooktop (Type 2 failure).E8Generator synchronization error.E9Temperature measurement error.EAGenerator error.ECSoftware error (Er64).EFHardware error (Er65).F-12Coil under currentF-12 E-12Coil under current on the power control board, affecting only one burner (Type…F-21Supply power frequency errorF-21 E-00Supply power frequency error from the power control board, affecting all…F-25Stuck fan on Induction Power System (IPS), right or left side fan depending on…F-25 E-25Stuck fan on power control board (right or left side fan, depending on which…F-36Temperature sensor is not workingF-36 E-36Temperature sensor is not working (Type 1 failure).F-37Temperature sensor is not workingF-37 E-37Temperature sensor is not working (Type 1 failure).F-40Stuck fan on Induction Power System (IPS) (Right or left side fan, depending on…MyPros+ Max
Get the full diagnostic procedure for any Whirlpool cooktop error code.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts
- Verified part numbers when replacement is required
Get started
$29/month · Cancel anytime · Or $9.95 3-day pass
F-40 E-XXPower control board failure error where XX will describe one of 13 possible…F-42Power supply issueF-42 E-00Power supply error from the power control board (Type 2 failure).F-43Under voltage on induction cooktop (Type 2 failure).F-43 E-00Power supply error from the power control board (Type 2 failure).F-47Power supply from power control board to User Interface is missing, or WIDE…F-47 E-35Power supply from power control board to User Interface is missing, or WIDE…F-47 E-39Power supply from power control board to User Interface is missing, or WIDE…F-47 E-47Power supply from power control board to User Interface is missing, or WIDE…F-56Power supply from Induction Power Control (IPC) to User Interface is missing or…F-56 E-00Wrong or invalid configuration, disabling the entire cooktop (Type 3 failure).F-58Wrong or invalid configurationF-58 E-58Wrong or invalid configuration on the power control board (Type 2 failure).F-60UI (User Interface) does not workF-61IPC does not workF-81 E-00Over temperature condition due to insufficient ventilation (Type 2 failure).F-82 E-00Over temperature condition due to insufficient ventilation (Type 2 failure).F0E0No error codes present in the systemF0E1Cookware is detected but it is not compatible with the requested operation or…F0E2Main relay is stuck in the closed position and cannot open.F0E3Coil NTC open / Coil NTC short / Coil NTC stuck.F0E4Inverter under currentF0E5The control panel switches off because of excessively high temperatures.F0E6Product supply error including possible fuse track action, mains line frequency…F0E7Wrong power cord connectionF0E8Wrong IPC configurationF0E9The control panel switches off because of excessively high temperatures.F0EAThe control panel switches OFF because of excessively high internal…F0ECCoil NTC open circuit detected.F0EDCoil NTC open / Coil NTC short / Coil NTC stuck.F1-E2Lower RTD uncalibrated (internal oven control failure).F1-E5Sensor usage out of range (internal oven control failure).F1-E9WIDE Queue full.F1E0Replace UI or Model MismatchF1E1Inverter checks failureF1E7User interface board failure (check user interface).F2-E0Keypad disconnected from oven control.F2-E2Stuck key on oven control keypad.F2E1Stuck or shorted keypad detectedF3-E0Main oven temperature sensor open or shorted (upper oven).F3-E1Main oven temperature sensor open or shorted (lower oven).F3E2Oven temperature sensor fault (implied secondary main sensor fault).F5-E0Door and door position switch(es) do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F6-E2Over temperature during clean mode (runaway temp).F6-E3Over temperature in warming drawer (runaway temp).F6E0User Interface lost communication contactF6E1Communication errorF6E4User Interface and Appliance Manager state status mismatch.F6E6Appliance Manager 1 (Copernicus) lost communication contact (WIN bus…F6E8Communication error.F6E9Appliance Manager 2 (Expansion Board) lost communication contact (WIN bus…F6EAUser Interface over temperatureF7E5Fan speed errorF7E6Fan blockedF9E0Mis-wire of the product detected; 240VAC applied across the control instead of…U400Over voltage condition.