mypros+
MyPros+ Max

Get the full diagnostic procedure for any Whirlpool oven error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

C-83Induction cooktop temperature sensor stuck (Type 2 failure).E0Key held down too long or key is shorted (under F2).E0 E5 E7 E9Internal board failure (F1).E0 F0No failure (GOOD)E0 F1EEPROM communication error (internal control failure).E0 F2Keypad disconnected from control.E0 F3Main oven temperature sensor open or shorted (upper cavity).E0 F5Door and latch switches do not agree during Clean mode.E0 F6Lost communications between user interface and appliance manager.E0 F9Range is mis-wired (incorrect power supply wiring).E1Oven temperature sensor open or shorted (upper or lower oven depending on…E1 E5Oven user interface failure.E1 F1Check oven appliance managerE1 F2Stuck or shorted key on keypad.E1 F3Main oven temperature sensor open or shorted (lower cavity).E1 F5Door latch not operating during Clean mode.E1 F6Over temperature condition during cook mode (runaway temperature).E2Oven temperature too high or runaway oven condition.E2 F1Lower RTD uncalibrated (internal control failure).E2 F2Stuck key detected on keypad.E2 F3Warming drawer sensor shorted or open (oven not equipped with this feature).E2 F6Over temperature condition during clean mode (runaway temperature).E3Wiring harness cavity size select jumpers indicate a cavity size different from…E3 F3Meat probe shorted.E3 F6Mini oven/warm drawer over temperature (oven not equipped with this feature).E4Door latch unlock failureE4 F6User interface / appliance manager mismatch.E5Control board failureE5 F1Sensor usage out of range (internal control failure).E5 F6No cavity size command programmed in control.E6CANCEL key drive line open (under F2).E7Self clean latch will not unlock.E7 F1PCB thermistor/sensor open or shorted.E9 F1WIDE Queue full (internal communication buffer overflow).EEPROMEEPROM communication error.F-12Induction cooktop coil under current (Type 1 failure, affects only one burner).F-21Induction cooktop supply power frequency error (Type 2 failure, affects all…F-25Stuck fan on Induction Power System (IPS)F-36Stuck fan on Induction Power System (IPS) (right or left side fan, depending on…F-37Stuck fan on Induction Power System (IPS) (right or left side fan, depending on…F-40Induction Power System (IPS) failure (Type 1 or Type 2).F-42Induction cooktop power supply issue (Type 2 failure).F-43Induction cooktop under voltage (Type 2 failure).F-47Power supply from Induction Power Control (IPC) to User Interface is missing…F-56Wrong or invalid configuration (Type 3 failure, disables entire cooktop).F-58Wrong or invalid configuration on the Induction Power System (IPS).F-60UI does not work (Type 3 failure, disables entire cooktop).F0Default F codeF0-E0Default F codeF0-E3Wiring harness cavity size does not match previously stored valueF01Temperature probe failureF02Welded (stuck closed) element relays detected on the electronic control.F03A.MF04WISP protocol doesn't work (communication error between oven power unit and hob…F05Door or latch problems (door latch assembly, motor, or switch malfunction).F06Door closure failureF07Gemini/Capricorn failure (short circuit)F08UI EEPROM failure (TAD models).F09Communication failure between G2SMART and Antares (TAD models).F1Control failure series: potential runaway oven condition (F10F1 E3Configuration jumper change; freestand, electric switches or P3 pins 1 to 5…F1 E8Improper keypad feedback (power board supply lift).F1-E4Electronic control malfunction (E4 variant).F1-E6Electronic control malfunction (all E codes under F1 indicate electronic…F1-E7 (cooktop)PCB thermistor/sensor open or shorted on the cooktop control.F1-E9 (cooktop)WIDE queue full on the cooktop control.F10Primary grill heating element failure (Pyro models only).F11Communication failure between G2SMART and TEX (TAD models).F1E0User Interface Board EEPROM Communication ErrorF1E0 (cooktop)EEPROM communication error on cooktop (EGO) control.F1E1Control Relay Board EEPROM Communication ErrorF1E2Lower RTD UncalibratedF1E5Sensor Usage Out of RangeF1E7PCB Thermistor Open or ShortedF1E9WIDE Queue FullF1EAMain ACU over temperature condition.F1EBControl panel not working/Control panel not accepting commands.F2Default F codeF2 E3Key held down too long or keyboard short or spill on switch surface.F2 E5Cancel key drive line open.F2-E1 (cooktop)Stuck key detected on the cooktop control keypad.F2E0Keypad DisconnectedF2E1Stuck KeyF2E2Cancel or Off Key Error/Warming Zone Off Keypad ErrorF2E4Temperature Too Low (cooking times too long, not getting desired results) or…F2E6Keypad error (microwave generation related).F3Oven sensor open circuit, oven sensor short circuit, bake/broil excessive…F3 EOOven sensor open or shorted (humidity sensor 1600).F3-E4Bottom oven temperature sensor open (bottom oven sensor open).F3-E5Bottom oven temperature sensor shorted (bottom oven sensor shorted).F3-E7Warming drawer temperature sensor shorted.F3E0Main Sensor Open or Shorted (Upper)F3E1Main Sensor Open or Shorted (Lower)F3E2Warming drawer sensor short-circuited (not applicable to this oven; reprogram…F3E3Main Oven Meat Probe Short-CircuitF3E6Powered Accessory (PA) over temperature.F3E8Main oven Powered Accessory (PA) mismatch.F3E9Left Oven Meat Probe Short-CircuitF4Temperature sensor opened or temperature sensor shorted; oven temp too highF4 E2Over temperature during cook mode (temperature runaway).F4 E3Over temperature during clean mode (temperature runaway).F4 E7Over temperature cavity 2 (temperature runaway error).F4-E0Door is open but latch is locked (door switch indicates open door and latch…F4E1Microwave Oven Magnetron Thermistor Open or ShortedF4E4Microwave Oven Humidity Sensor Open or ShortedF4E8Inverter over temperature.F4E9Inverter and magnetron over temperature.F5Door and latch switch mismatch during clean mode, or door latch not functioning…F5 E6Lower door switch reads constant high.F5 E7Door unlocked but will not unlatch after clean cycle.F5 EODoor and latch switch do not agree.F5-E5Self clean temperature (288°C [550°F]) not reached within 45 minutes.F5E0Door and Latch Switches Do Not AgreeF5E1Latch Not OperatingF5E2CLEAN range over temperature, or door and door position switches do not agree…F5E3Left Oven Door Latch SwitchF5E3 (Inputs)Door and latch switch do not agree (lower oven).F5E4Left Oven Door Latch MotorF6Switch pulse return line not connectedF6 E0 (cooktop)Right cooktop communication error.F6 E1 (over temp)Over temperature during cooking.F6 E4 (cooktop)Left cooktop communication error.F6 E7Lost communication with MWO appliance manager.F6 E8Lost communications with Microwave Oven Appliance Manager.F6 EAUser interface over temperature.F6 EBDouble lower ovenF6E0User Interface ConnectionF6E1Over Temp CookF6E2Over Temp CleanF6E3Left Oven Over Temperature LimitF6E4Control StatusF6E5Mini oven/warm drawer over temperature (oven not equipped with this feature).F6E5 (cooktop)Oven control communication error (from cooktop control perspective).F6E6Main Oven Control ConnectionF6E9Left Oven Control ConnectionF7Common wire (+5VDC) to latch switch and door switch is shorted to chassis…F7-E0BoilerF7-E3Incorrect filter reset.F7-E4Conductivity sensor not connected.F7E1Boiler Over Temperature Limit (steam models)F7E2Boiler Temperature Out of Range (for steam models)F7E5Main cooling fan errorF7E6Microwave Inverter and Magnetron fault.F8Defective electronic oven controlF8-E4Oven over temperature while door close and latch unlock.F8-E6Left fan at high speedF8E0Cooling Fan Speed Too LowF8E1Left Oven Cooling Fan Speed LowF8E2Cooling Fan Speed Too HighF8E3Left Oven Cooling Fan Speed HighF9Door motor mechanism failure (F90 to F94)F9E0Error code listed in error code table (specific description not fully legible…F9E4User interface/Appliance manager state status mismatch.FBE1Main Door Latch motor has failed to lock/unlock.FCE1Secondary Door and Latch Switches Do Not Agree (Lower Oven).FCE2Model/serial numbers do not match.FCE3Common Failure Between Main ACU and HMI.FEE6Main Cavity Bake Element open circuit.FEE7Main Cavity Broil Element open circuit.FEE8Main Cavity Convect 1 Element open circuit.FEE9Main Cavity Convect 2 Element open circuit.FEEAMain Cavity Convect 2 Element open circuit.FEEBSecondary Cavity Broil Element open circuit.FEECConvection element open circuit.FEEDSecondary Cavity Convect 2 Element open circuit.Microwave Oven Inverter ErrorMicrowave oven inverter errorNo DisplayControl is blankPFPower failure indication (not a failure mode).SABOven is in Sabbath Mode.

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started