1 document53 error codes8 service modes

Available documentation

Service Manual

  • SERVICE MANUAL ActiveSmart™ Slide-in refrigerator RS90 and RS36 models74 pg
    Covers this model
MyPros+ Max

Diagnose your Fisher & Paykel RS36A72U1.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (53)

CodeMeaning
1On the last power up, the control module failed self test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected; either the heater…14The low ambient heater is drawing more current than expected; either there is a…15The PC fan is drawing less current than expected; either the wiring is open…16The PC fan is drawing more current than expected; either the wiring is shorted…17The FC fan is drawing less current than expected; either the wiring is open…18The FC fan is drawing more current than expected; either the wiring is shorted…2The previous 2 defrosts were aborted after 40 minutes.20The flapper heater current is low21The flapper heater current is high22The resistance of the water tank (PC2) sensor is outside the normal range (>…23The resistance of the water tank (PC2) sensor is outside the normal range (<…24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)25The resistance of the ice tray sensor is outside the normal range (< 660 Ohms)26The icemaker motor has timed out; the icemaker gearbox is not returning to the…27The icemaker motor current is high28The icemaker solenoid is drawing more current than expected; either there is a…29The icemaker solenoid is drawing less current than expected; either the wiring…3The resistance of all the temperature sensors are outside the normal range (>…30Display harness fault31Display harness fault4The resistance of all the temperature sensors are outside the normal range (<…40Icemaker solenoid transistor 1 short circuit.41Icemaker solenoid transistor 2 short circuit.42Icemaker fill tube heater short circuit43Icemaker fill tube heater open circuit49Communication error between control module and inverter.
View all 53 error codes

Service modes (8)

  • Diagnostic ModePress and hold the COMPARTMENT and WARMER buttons together for 4 seconds
  • Disable Water Filter WarningPress the COMPARTMENT, ALARM MUTE, and WARMER buttons together for 4 seconds.
  • Forced Defrost ModePress the COMPARTMENT and COLDER buttons together for 4 seconds.
  • Forced Ice Harvest ModePress the ALARM MUTE, COLDER, and WARMER buttons together for 4 seconds, then close the PC door.
  • Optical Download ModeEnter diagnostic mode (COMPARTMENT + WARMER for 4 seconds), then press the COLDER button
  • Reset Water Filter IconPress the ALARM MUTE and WARMER buttons together for 4 seconds.
  • Sabbath ModePress the COMPARTMENT, ALARM MUTE, and COLDER buttons together for 10 seconds.
  • Showroom ModePress the COMPARTMENT, WARMER, and COLDER buttons together until a long beep is heard.

Full entry steps, exit procedures, and test sequences are available in Max.