4 documents41 error codes6 service modes

Available documentation

Service Manual

  • SERVICE DISHWASHER Manual72 pg
    Covers this model
  • samsung dishwasher service manual DW9900H DW80J755086 pg
    Covers this model

Bulletin

  • The door does not close correctly or opens during the cycle4 pg
    Covers this model

Installation Guide

  • DW80H99* Series Dishwasher installation guide72 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung DW80H9930US/AA-0000.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (41)

CodeMeaning
1CHigh pressure switch or circulation pump power consumption indicates low water…1EHigh pressure switch does not measure high level after water supply completion…3CCirculation pump failure3ECirculation pump failure4CWater supply failure4C5200 water supply pulses detected during non-water supply mode; cycle continues…4EWater supply failure4E5200 water supply pulses detected during non-water supply mode.5CDrain pump failure5C1Drain pump check code occurred 11 times with 5-minute pause and retry; driving…5EDrain pump failure7CWaterwall vane motor failure7EWaterwall vane motor failure9C1Blackout or DC link voltage is abnormally high or low; driving parts stop…9C2Blackout or DC link voltage is abnormally high or low; driving parts stop…9E1Blackout or DC link voltage is abnormally high or low; switches to stop mode.9E2Blackout or DC link voltage is abnormally high or low; switches to stop mode.ACCommunication failure between Main PBA and Sub PBA for 24 seconds; cycle…AC6No response from Inverter PBA for 3 seconds; Inverter relay off for 2 minutes…AECommunication failure between Main PBA and Sub PBA for 24 seconds (6 seconds in…AE6No response from Inverter PBA for 3 seconds; Inverter relay off for 2 minutes…bC2Touch button pressed and held for 30 continuous seconds or longer; cycle…bC3IC communication failure between the Sub PBA and the touch button; cycle…bE2Touch button pressed and held for 30 continuous seconds or longer; no display…bE3IC communication failure between the Sub PBA and the touch button; no display…C3Turbidity sensor reference voltage cannot be reached after 10 seconds of…dCDoor open during test mode; mode does not start automatically if door is open.dEDoor open during test mode; mode does not start automatically if door is open.E3Turbidity sensor reference voltage cannot be reached after 10 seconds of…HCHeater overheat
View all 41 error codes

Service modes (6)

  • Check Code Recall (S/W ver. ~7133)Press Power (make it power on), then press Normal and Lower key for 3 seconds.
  • Linear Auto Test Mode (LA)Push Booster left key + Booster right key + Power key at the same time. Then push the Linear Auto…
  • Service Inspection ModePress the 'Auto' + 'Delicate' + 'Power' buttons at the same time for two seconds.
  • Service Inspection Mode (SVC Test Mode)Press the Auto, Delicate, and Power buttons at the same time for two seconds to enter Service…
  • SVC Data Display ModeWhen the power is on, press and hold the Auto key and Express key combination for 2 seconds.
  • Test Mode (Version Check)Press the Zone booster L, Zone booster R, and Power key at the same time to enter test mode