mypros+
Model reference

GE GWE23

Refrigerator

1 document94 error codes10 service modes

Available documentation

Service Manual

  • Appliance Service Diagnostic Functions and Specifications2 pg
    Covers this model
MyPros+ Max

Diagnose your GE GWE23.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (94)

View all 94 error codes
0400Mainboard Software Fault0401Can't reach Target Hot Water Temp0402Flow meter0403Flow meter signal received with no water dispensing0500Paddle switch pressed > 7 minutes0501Hot water tank not full while heating0504Check Paddle switch and wiring0505Check Paddle switch and wiring0506Check Hot water T&P switch and wiring0507Check Hot water T&P switch and wiring0508FF IM Thermistor reading out of range0509Ice Box Thermistor reading out of range0510Hot Water Thermistor reading out of range0511Hot Water Thermistor reading out of range0512Door board Hardware fault0513Hot Water tank Fault0514Door board Hardware fault0515Low Flow Rate, Hot Water Disabled0517HW Max Fill Time Out Hot water disabled0518HW Max Dispense Time Out Hot water disabled0519HW Max Purge Time Out Hot water disabled0520Feature Board communication error0521Dispense nozzle movement error0522Brew Module not detected during brew0523High flow during brewing0524Low flow during brewing0525Feature board hardware fault0601FF IM Harvest Extended >10 mins0602FF IM Harvest Extended 3 out of 10 harvests0603FF IM Harvest Not Completed after 30 mins0604FF IM No water supply detected0605FF IM continues to sense bucket full after ice dispense0606FF IM Moldheater not heating0651FZ IM Harvest Extended >10 mins0652FZ IM Harvest Extended 3 out of 10 harvests0653FZ IM Harvest Not Completed after 30 mins0654FZ IM No water supply detected0655FZ IM Moldheater not heating0700Stuck keys on Dispenser Boards0701Stuck Keys on Internal Temp Board0702Stuck Keys on Deli Pan0703Key Press on Temp Board while Door Closed0704Key Pressed on Deli Pan Board while Door Closed0705Dispenser Board AutoFill Error0706Dispenser Board AutoFill Error0707Dispenser Board Error0708Dispenser Board Error0709Check Paddle switch and wiring0710Check Paddle switch and wiring0711Check Hot water T&P switch and wiring0712Check Hot water T&P switch and wiring0713FF Door open for 15 minutes continuously0714FF Door open for 60 mins total in the last 24 hours0715100 FF Left Door Openings in the last 24 hours0716100 FF Right Door Openings in the last 24 hours0717FZ Door open for 15 minutes continuously0718FZ Door open for 60 mins total in the last 24 hours0719100 FZ Door Openings in the last 24 hours0721Upper AutoFill Sensor Error (Clean sensors)0722Display Board Error0800RFID board hardware failure / check filter and filter orientation0801RFID board failed to respond to MB0802RFID board not detecting filter tag / check filter and filter orientation0803RFID filter authentication failed / check filter and filter orientation

Service modes (10)

  • Fault Code Navigation (Cafe Models)["Enter service diagnostics (test 00 00)","Press up and down arrows to see multiple faults (3…
  • Fault Code Navigation (GE/Adora/Profile Models)["Enter service diagnostics (test 00 00)","Error code displayed first (xx xx), then how many times…
  • Fault Code Navigation (Profile Models with Keurig)["Enter service diagnostics (test 00 00)","Error code displayed first (xx xx), then how many times…
  • Fault Code Viewing (Test 00 00)["Enter Service Diagnostics (see above), test 00 00 is the default.","Cafe Models
  • Sabbath Mode["Internal Water Models
  • Sabbath Mode (Capacitive Touch Models)["Simultaneously press Lock and Light for 3 seconds"]
  • Sabbath Mode (Internal Water Models)["Simultaneously press Door Alarm and Icemaker buttons for 3 seconds"]
  • Sabbath Mode (LCD Models)["Simultaneously press Lock Controls and Light for 3 seconds"]
  • Sabbath Mode (Single Serve Capacitive Touch Models)["Simultaneously press Door Alarm and Light for 3 seconds"]
  • Service Diagnostics["Capacitive Touch (Autofill Units)

Full entry steps, exit procedures, and test sequences are available in Max.