Model reference
GE PFE28PSKDSS
Refrigerator
2 documents94 error codes9 service modes
Available documentation
Service Manual
- Technical Data - Service Diagnostic Functions2 pg
- 2012 Profile and GE French Door Refrigerators Service Manual91 pg
MyPros+ Max
Diagnose your GE PFE28PSKDSS.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (94)
CodeMeaning
0001FF Thermistor reading out of range.0003FZ Thermistor reading out of range.0004FZ Evaporator Thermistor reading out of range.0005Electronic Deli Pan Thermistor reading out of range.0006FF Evaporator Thermistor reading out of range.0008Ambient Temperature Thermistor reading out of range.0009Ambient Humidity Sensor reading out of range.0010FZ Icemaker Thermistor reading out of range (if applicable).0100FZ Fan Feedback Missing when Fan is running.0101FZ Fan Feedback Present when Fan is off.0102FZ Fan cannot reach target speed.0103Condenser Fan Feedback Missing when Fan is running.0104Condenser Fan Feedback Present when Fan is off.0105Condenser Fan cannot reach target speed.0106FF Fan Feedback Missing when Fan is running.0107FF Fan Feedback Present when Fan is off.0108FF Fan cannot reach target speed.0109Ice Box Fan Feedback Missing when Fan is running.0110Ice Box Fan Feedback Present when Fan is off.0111Ice Box Fan cannot reach target speed.0112Deli Pan Fan Feedback Missing when Fan is running.0113Deli Pan Fan Feedback Present when Fan is off.0114Deli Pan Fan cannot reach target speed.0200FZ Defrost Heater timed out (check FZ Evap thermistor fault code 0004).0201FF Defrost Heater timed out (check FF Evap thermistor fault code 0006).02025 consecutive FZ extended defrosts.02035 consecutive FF extended defrosts.0301Temperature satisfied > 3 hours (no compressor operation).0303FF Temp Exceeds > 55°F.0304FZ Temp Exceeds > 25°F.View all 94 error codes
0400Mainboard Software Fault.0401Can't reach Target Hot Water Temp.0402Flow meter0403Flow meter signal received with no water dispensing.0500Paddle switch pressed > 7 minutes.0501Hot water tank not full while heating.0504Check Paddle switch and wiring.0505Check Paddle switch and wiring.0506Check Hot water T&P switch and wiring.0507Check Hot water T&P switch and wiring.0508FF IM Thermistor reading out of range.0509Ice Box Thermistor reading out of range.0510Hot Water Thermistor reading out of range.0511Hot Water Thermistor reading out of range.0512Door board Hardware fault.0513Hot Water tank Fault.0514Door board Hardware fault.0515Low Flow Rate, Hot Water Disabled.0517HW Max Fill Time Out Hot water disabled.0518HW Max Dispense Time Out Hot water disabled.0519HW Max Purge Time Out Hot water disabled.0520Feature Board communication error.0521Dispense nozzle movement error.0522Brew Module not detected during brew.0523High flow during brewing.0524Low flow during brewing.0525Feature board hardware fault.0601FF IM Harvest Extended >10 mins.0602FF IM Harvest Extended 3 out of 10 harvests.0603FF IM Harvest Not Completed after 30 mins.0604FF IM No water supply detected.0605FF IM continues to sense bucket full after ice dispense.0606FF IM Moldheater not heating.0651FZ IM Harvest Extended >10 mins.0652FZ IM Harvest Extended 3 out of 10 harvests.0653FZ IM Harvest Not Completed after 30 mins.0654FZ IM No water supply detected.0655FZ IM Moldheater not heating.0700Stuck keys on Dispenser Boards.0701Stuck Keys on Internal Temp Board.0702Stuck Keys on Deli Pan.0703Key Press on Temp Board while Door Closed.0704Key Pressed on Deli Pan Board while Door Closed.0705Dispenser Board AutoFill Error.0706Dispenser Board AutoFill Error.0707Dispenser Board Error.0708Dispenser Board Error.0709Check Paddle switch and wiring.0710Check Paddle switch and wiring.0711Check Hot water T&P switch and wiring.0712Check Hot water T&P switch and wiring.0713FF Door open for 15 minutes continuously.0714FF Door open for 60 mins0715100 FF Left Door Openings in the last 24 hours.0716100 FF Right Door Openings in the last 24 hours.0717FZ Door open for 15 minutes continuously.0718FZ Door open for 60 mins0719100 FZ Door Openings in the last 24 hours.0721Upper AutoFill Sensor Error (Clean sensors).0722Display Board Error.0800RFID board hardware failure / check filter and filter orientation.0801RFID board failed to respond to MB.0802RFID board not detecting filter tag / check filter and filter orientation.0803RFID filter authentication failed / check filter and filter orientation.
Service modes (9)
- Auto Fill Sensor Diagnostic (PFE29)1. Wake the screen. 2. Simultaneously press and hold the Water, Cubed, and Precise Fill buttons for…
- Dealer Demo Mode (GE/Adora LED Models)Press the Refrigerator and Freezer up arrow buttons simultaneously.
- Dealer Demo Mode (LCD Models - PFE29)Press Lock Controls and Precise Fill pads simultaneously for 3 seconds
- Demo Mode["Internal Water Models
- Sabbath Mode["Internal Water Models
- Sabbath Mode (GE/Adora LED Models)Press and hold the Dispenser Light and Lock Controls buttons for 3 seconds.
- Sabbath Mode (LCD Models - PFE29)Press and hold simultaneously the Lock Controls and Light buttons for 3 seconds.
- Service Diagnostic ModePress the Water, Crushed, and Cubed buttons simultaneously for 3 seconds. The display will show…
- Service Diagnostics["Capacitive Touch
Full entry steps, exit procedures, and test sequences are available in Max.
Related GE refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass