Model reference
Fisher & Paykel 321154
Refrigerator
1 document37 error codes8 service modes
Available documentation
Service Manual
- 2013 Active Smart Refrigerator/Freezer Service Manual146 pg
MyPros+ Max
Diagnose your Fisher & Paykel 321154.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (37)
CodeMeaning
1On the last power up, the power/control module failed self test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected14The low ambient heater is drawing more current than expected15The PC fan is drawing less current than expected16The PC fan is drawing more current than expected17The FC fan is drawing less current than expected18The FC fan is drawing more current than expected2The previous 2 defrosts were aborted after 40 minutes.20The flapper heater current is low.21The flapper heater current is high.22The resistance of the ambient sensor is outside the normal range (> 45K Ohms)23The resistance of the ambient sensor is outside the normal range (< 660 Ohms)24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)25The resistance of the ice tray sensor is outside normal range (< 660 Ohms)26The icemaker motor timed out27The icemaker motor current is high.28The icemaker solenoid current is high.29The icemaker solenoid current is low.3The resistance of all the temperature sensors are outside the normal range (>…30Display harness fault31Display harness fault32Display water transistor 1 failure.33Display water transistor 2 failure.34Display water transistor 1 & 2 failure.4The resistance of all the temperature sensors are outside the normal range (<…40Icemaker solenoid transistor 1 short circuit41Icemaker solenoid transistor 2 short circuit.View all 37 error codes
42Icemaker fill tube heater short circuit (no audio alarm for this fault).43Icemaker fill tube heater open circuit (no audio alarm for this fault).5The resistance of the FC sensor is outside the normal range (> 45K Ohms).6The resistance of the FC sensor is outside the normal range (< 660 Ohms).7The resistance of the Evaporator sensor is outside the normal range (> 45K…8The resistance of the Evaporator sensor is outside the normal range (< 660…9The resistance of the PC sensor is outside the normal range (> 45K Ohms).
Service modes (8)
- Diagnostic ModePress and hold the COMPARTMENT and WARMER buttons together for 4 seconds.
- Fault History (Diagnostic Mode 8)Enter Diagnostic mode (COMPARTMENT + WARMER for 4 seconds), then press WARMER button 7 times.
- Force Icemaker HarvestPress and hold the ALARM MUTE, COLDER and WARMER buttons together for 4 seconds, then close the PC…
- Input/Output Display (Diagnostic Mode 5)Enter Diagnostic mode (COMPARTMENT + WARMER for 4 seconds), then press WARMER button 4 times.
- Manual Defrost ModePress and hold the COMPARTMENT and COLDER buttons together for 4 seconds.
- Optical Download Mode (Diagnostic Mode 1)First enter Diagnostic mode (press and hold COMPARTMENT and WARMER for 4 seconds), then press the…
- Sabbath Mode (Special Option Mode)Push and hold the COMPARTMENT, ALARM MUTE and COLDER buttons on the LED display interface for 10…
- Show Room ModePress and hold the COMPARTMENT, COLDER and WARMER buttons together until a long beep is heard…
Full entry steps, exit procedures, and test sequences are available in Max.