mypros+
Model reference

Samsung ND072CHXCB

Air Conditioner

4 documents68 error codes3 service modes

Available documentation

Service Manual

  • LG Samsung AVXWNH072CE ND052CHXCB ND072CHXCB Precaution2 pg
    Covers this model
  • LG Samsung AVXWNH072CE ND052CHXCB ND072CHXCB Troubleshooting122 pg
    Covers this model

Tech Sheet

  • LG Samsung AVXWNH072CE ND052CHXCB ND072CHXCB Product Specification54 pg
    Covers this model

Wiring Diagram

  • LG Samsung AVXWNH072CE ND052CHXCB ND072CHXCB Wiring Diagram16 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung ND072CHXCB.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (68)

CodeMeaning
121Indoor unit room temperature sensor error (Open/Short)122Indoor unit heat exchanger IN sensor error (Open/Short)123Indoor unit heat exchanger OUT sensor error (Open/Short)128Indoor unit heat exchanger IN sensor dislocation error.129Indoor unit heat exchanger OUT sensor dislocation error.130Simultaneous indoor unit heat exchanger IN and OUT sensor dislocation error.135Indoor clean fan rotational frequency feedback error.1512nd opening error of indoor electrically operated valve (EEV).1522nd closing error of indoor electrically operated valve (EEV).153Indoor floating sensor error (drain pump float switch detection).154Indoor fan motor error161Mixed operation error162EEPROM error163Indoor unit remote controller option input is wrong or not entered (EEPROM…170Mixed use of Fahrenheit/Celsius setup185Power input error into indoor unit communication line186Clean Unit (SPi) feedback error.201Communication error between indoor and outdoor units after completing initial…202Communication error among all indoor units.203Communication error between main and sub outdoor units or between main and sub…221Outdoor unit temperature sensor error (Open/Short)226Outdoor temperature sensor dislocation error.231COND OUT main temperature sensor error (Open/Short)241Outdoor COND OUT temperature sensor dislocation error.246Outdoor COND OUT temperature sensor dislocation error (RD040/050 model).251Digital compressor discharge temperature sensor error (Open/Short)257Fixed scroll compressor 2 discharge temperature sensor error (Open/Short)258Fixed scroll compressor 3 discharge temperature sensor error (Open/Short)261Digital compressor discharge temperature sensor dislocation error.263Fixed scroll compressor 2 discharge temperature sensor dislocation error.
View all 68 error codes
264Fixed scroll compressor 3 discharge temperature sensor dislocation error.265SUMP sensor dislocation error.269SUCTION sensor dislocation error.271SUMP temperature digital sensor error (Open/Short)291High pressure sensor error (Open/Short)296Low pressure sensor error (Open/Short)307Oil balance valve (balance keeping) temperature sensor error (Open/Short)308Suction temperature sensor error (Open/Short)311Liquid pipe (double pipe) temperature sensor error (Open/Short)312Main cooling solenoid valve open error.320OLP sensor error (Open/Short).321EVI IN temperature sensor error (Open/Short)322EVI OUT temperature sensor error (Open/Short)403Freezing control causes compressor down407Compressor down by high pressure sensor protection control410Compressor down by low pressure sensor protection control413Protection control by SUMP sensor416Compressor down by discharge temperature425Outdoor compression ratio error / 3-phase reverse phase or phase fail detection428Compressor down by compression ratio control431Balance keeping valve 1 (oil valve) self-diagnosis438EVI EEV opening error.440Prohibit heating operation for outdoor temperature over 86F/30C.442Prohibit heat filling mode for outdoor temperature over 59F/15C.443High pressure below the average before cooling452Instant blackout error / outdoor unit power frequency error.453Error by high temperature outdoor fan motor454Outdoor fan RPM error456Outdoor fan over-voltage error457Outdoor fan counter-rotation error458Over-voltage error detected in compressor current sensor461Low-voltage (low-amperage) error detected in compressor current sensor462Current protection control causes compressor down463OLP protection control causes compressor down475Electrical malfunctions of the outdoor machine (fan stuck, poor connection…477Liquid compressor protection control7021st close indoor electrically operated valve error.7031st open indoor electrically operated valve error.

Service modes (3)

  • PCB Option Code Input Mode (10-digit, e.g., 660157022E, for AVXWNHC/NDN models)["Step 1: Remove batteries from remote control.","Step 2: Press both temperature buttons…
  • PCB Option Code Input Mode (12-digit code, e.g., 021E31142285)["Step 1
  • PCB Option Code Input Mode (12-digit with dash, e.g., 066064-170373, for AVXWVHC/NDV models)["Step 1: Remove batteries from remote control.","Step 2: Press both temperature buttons…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass