Model reference
Whirlpool YWFE745H0FH2
Range
12 documents55 error codes34 service modes
Available documentation
Tech Sheet
- Tech Sheet16 pg
- TechSheet-W10843072-RevA(FR).pdf8 pg
- TechSheet-W10843071-RevA.pdf8 pg
- Fiche technique - Tech Sheet W107232148 pg
- Tech Sheet - W10723213 - Rev A8 pg
- Wiring Diagram - W10843087 - Rev A2 pg
Service Manual
- Tech Manual16 pg
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
- Technical Manual - Cooking Surface Temperature Limits12 pg
Quick Reference
- Freestanding Electric Range Control Guide20 pg
- Quick Start Guide2 pg
Other
- Wiring Sheet - W11336171 - Rev A2 pg
MyPros+ Max
Diagnose your Whirlpool YWFE745H0FH2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (55)
CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1 E0EEPROM communication error.F1 E5Sensor out of range.F1 E7Circuit board thermistor open or short-circuited.F1-E0EEPROM communication error within the MRC control.F1-E5Sensor out of range detected by MRC control.F1-E7PCB thermistor open or shorted.F1E0EEPROM communication error.F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2 E0Keypad disconnected.F2 E1Key stuck.F2 E2Cancel key error.F2-E0Keypad disconnected from control.F2-E1Stuck key detected on the keypad.F2-E2Cancel key error on the keypad.F2E0Keypad disconnected.F2E1Stuck key.F2E2Cancel key error.F3Temperature sensor faultF3 E0Main oven sensor open or short-circuited.F3 E2Warming drawer sensor open or short-circuited.F3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer temperature sensor open or shorted.F3E0Main oven sensor open or shorted.F3E1Oven sensor shorted (LCC/LCX control).F3E2Warming drawer sensor open or shorted.View all 55 error codes
F3E3Clean range over temperature (LCC/LCX control).F5Door-related faultF5 E0Door and switch mismatch (clean modeF5 E1Door latch not functional (clean modeF5-E0Door and door position switch do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and switches do not agree (Clean modeF5E1Door latch not operating (Clean modeF5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6Over temperature conditionF6 E1Bake modeF6 E2Clean modeF6 E3Warming drawerF6-E1Over temperature condition during cook mode.F6-E2Over temperature condition during clean mode.F6-E3Over temperature condition in warming drawer.F6E0Oven User Interface lost communication between UI and ACU (Indigo control).F6E1Over temperature during cook mode.F6E2Over temperature during clean mode.F6E3Over temperature in warming drawer.F6E4Oven User Interface UI and ACU state status mismatch (Indigo control).F8E0Cooling fan speed too lowF8E2Cooling fan speed too highF9Mis-wired house or range (E0).F9E0Mis-wired house or range (Maxwell/MRC control).
Service modes (34)
- Auto TestFrom diagnostic mode (CANCEL>CANCEL>START), press up arrow, '+', or '3' to scroll to 'AUTO TEST'…
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Maxwell/MRC Controls)1
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- CONTROL RESETFrom diagnostic mode, scroll to step 6 (CONTROL RESET).
- Diagnostic / Service ModePress CANCEL > CANCEL > START
- Diagnostics / Service ModePress CANCEL > CANCEL > START
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Auto Test)["Press CANCEL","Press CANCEL","Press START (display shows 'TEST ON' with cavity temperature and…
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Mode (Service Mode Entry)Press CANCEL > CANCEL > START
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- DISPLAYFrom diagnostic mode, scroll to step 5 (DISPLAY).
- ENG MODEFrom service mode, scroll to step 2 (ENG MODE). Press START to enter, then press '+' keypad. Press…
- ENG MODE (Engineering Mode)From diagnostic mode, scroll to step 2 (ENG MODE)
- FAULTSFrom diagnostic mode, scroll to step 7 (FAULTS).
- MRC Control Module Diagnostic ModePress CANCEL, then CANCEL again, then START
- RELAY USAGEFrom diagnostic mode, scroll to step 8 (RELAY USAGE).
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature Adjustment1
- TEST MODEFrom service mode, scroll to step 3 (TEST MODE)
- TEST MODE (Relay Control)From diagnostic mode, scroll to step 3 (TEST MODE)
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
- TEST ON (Relay Checks)Upon entry into service mode (CANCEL > CANCEL > START), TEST ON is displayed
- TEST ON (Relay Control)Entered immediately upon entering diagnostic mode (CANCEL>CANCEL>START)
- USAGEFrom diagnostic mode, scroll to step 1 (USAGE) using up arrow, '+', or '3'.
- VERSIONFrom diagnostic mode, scroll to step 4 (VERSION).
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass