Skip to main content
Error code reference
Fisher & Paykel Dryer Error Codes
49 error codes documented with diagnostic procedures.
Have your model number? Get codes specific to your unit.
#14Sensor module failure.#15Sensor module failure.#16Airflow restriction (User Warning)#22Door actuator is open circuit.#28Brown-out data retrieval error following a loss of power.#29Data retrieval error#4Invalid option link read#7Motor current is excessive.1Communications failure between the sensor module and motor control module.1024 Volt supply measurement error105There is no communication between the control board and user interface (UI communication…11Lid lock open circuit.12Lid lock switching device failure.151Drum failure (alternate display code for E7).157Model not defined (alternate display code for ED).2Drum gap cannot be located by the optical sensor on the drum tachometer.20Door actuator stalled.21Door actuator required excess voltage.23Door actuator movement was interrupted by low voltage (brown out).233EEPROM read error (LCD models only)-the sensor module has problems reading the EEPROM…24Door actuator movement took too long.3Drum stalled (no mechanical movement or tachometer signal lost).30Lid lock unable to lock45Display Module ROM Check Error-on power up, the display has checked its memory against a…6Door jammed (User Warning)-the door is unable to close due to either clothes catching or…7BDisplay Module RAM Check Error-on power up, the display has checked its memory against a…8Exhaust sensor over temperature-the exhaust sensor measures over temperature (element…9Exhaust sensor under temperature-the exhaust sensor measures under temperature (open…E0No error or all error erase.E1Inlet thermistor short circuit.E2Outlet thermistor short circuit.E3Inlet thermistor open circuit.E4Outlet thermistor open circuit.E5Inlet thermistor signal failure.E6Outlet thermistor signal failure.E7Drum failure.E8Door switch signal fail.E9Sensor rod short circuit.EASensor rod open circuit.EBSensor rod signal is static.ECProgramming end erasure endurance near to the limit (flash memory).EDModel not defined.Err2The float switch or pump has failed in the condensate collection tank.Err3The exhaust NTC thermistor and/or its related circuitry have malfunctioned.Err4The heater and/or its related circuitry have malfunctioned (no change in temperature).Err6The lint filter or condenser has restricted air flow (vent duct is restricted).Err9The heater NTC thermistor and/or its related circuitry have malfunctioned.ErrAThe belt switch is open or disconnected; belt may be broken.oPnUser warning indicating door is open or obstructed from closing properly.
Get the full diagnostic procedure for any code
Step-by-step tests, expected values, wiring diagram references, and verified part numbers.
Get Started $9.95 3-day pass$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.