Error code reference

Fisher & Paykel Washer Error Codes

176 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
#234Lid Lock Fault1Motor Controller Module (Display Module for Phase 1) has encountered an error when…10Temperature sensor (thermistor) may be open circuit or ambient temperature is below -10°C…103Slave display comms timeout.104Communications error between Display module and Motor Controller (Phase 2 to 6)105Display to Motor Control Module communications time-out error106Display to Motor Controller Module communications errors; Display Module detects an error…107Motor Controller Module reset error108Phase 6 IW109AC pump triac over temperature11While measuring the water level, the Motor Controller micro has detected a negative…110Motor bridge thermistor open circuit111Motor Control Module fault requiring replacement.112Motor current sense too high113AC Pump thermistor short circuit114Smart pump current sense circuit within the motor control module is faulty.12Flood protection error127Machine setup error13Phase 1 Pump Fault130Single Rotor Position Sensor Error131Repetitive Rotor Position Sensor error132Single current trip133Repetitive current trip134Single Current Trip and Rotor Position Error simultaneously136Motor stall; Motor Controller Module unable to start the motor due to faulty motor…137Motor loss of a phase14Phase 1 Pump Connection Fault144Phase 1 Motor Control Module Software Trap15Phase 1 Display Module Fault16Motor controller has detected that the display type has not been set.160Basket engaged161Hardware / EEPROM Supply Mismatch162Phase 3 to 5 Brake Deceleration Time-out Fault163Valve Reset Pin Connect Fault164Brake function time-out fault17Phase 118Phase 119Phase 1192Motor PMW Reset Pin Connect Fault2Phase 120Phase 121Water valve circuit is drawing too high a current.22Phase 1220EEPROM model map not programmed-Motor Control Module detected a fault in its memory on…221Motor Control Module RAM check error.222Motor Control Module stack error.223Motor Control Module program counter error.224Motor Control Module peripheral error.225Motor Control Module clock error.226MarchX RAM check error in Motor Control Module.23Phase 1230EEPROM Value out of Range231MW GW Link Error232Phase 6 IW: Communications timeout 5 seconds233Phase 6 EEPROM Read Error235Lid Lock Short Circuit236Phase 6 Incompatible EEPROM Version237Temperature Sensor Error238Lid lock open circuit-check harness to lid lock and connections at Motor Control Module…239Lid lock short circuit24Dispensing type not set in the Motor Control Module.240Hall out of order / RPS fault241Function time out-a fault has occurred with the Display Module.242OOB Hit Greater than Max for 5 Sec243Stepper Test Failure245Smart pump stall246Wash boost / bleach valve fault247Smart pump flapper fault248SmartPump top up fault249SmartPump timeout fault25Phase 5 IW250SmartPump loss of sync-pump not starting, usually caused by an object under or on top of…252Motor bridge test failure253Smart pump over current254Motor Control version too old26Valve fault27Valve fault28Phase 129Phase 13Motor Controller RAM error during initialisation procedures.30Phase 132The Display Module has detected that the pump is on when it is off (Phase 1 Pump Circuit…33Phase 1 Water Valve Fault34Phase 1 Brake Resistor Fault35Phase 1 Motor Control Module Reset Error36Water Leak Fault37Pump Blocked Error38Pressure sensor fault39Tap or pressure sensor tube fault4Phase 1: Communications fault40During basket check, the Motor Controller found the basket is not engaged even though the…41Temperature Sensor Fault (Thermistor)42The Motor Controller has had confusing information feedback regarding the rotor (Phase 1…43The Motor Controller found the OOB (out of balance) switch signal indicates the switch is…44Water in Tub during Spin45Phase 5 Display Memory Check Fault46Phase 5 IW Display EEPROM Check47Basket dis-engage fault48Both hot and cold water valves faulty49Valve fault5Phase 1: Communications fault50Phase 2-6: Hot valve faulty51Phase 5-6 Eco: Diverter valve fault52Diverter Top-up Fault53Rotor Position Sensor Step Fail54Motor/Motor Controller Module step fail55Phase 3 to 6 System Step Fail56Basket check no valid fault57Phase 4 to 6 Brown Out During Display EEPROM Write Fault58Pressure transducer at maximum adjustment fault; Display Module checked memory on start…59Phase 4 to 5 ID Out of Range Fault6Phase 160Motor Controller memory check fault61Phase 4 Brown Out During Motor Control Module EEPROM Write62Pump over-current fault63Phase 5 Pump Comms Error64Pressure transducer error65Pressure transducer error66Phase 6: Pressure transducer error68Pressure transducer error69Pressure (sensor) transducer fault7Display micro has found a RAM error while testing RAM.70Pressure (sensor) transducer fault72Pressure transducer error73Pressure transducer error74Pressure transducer error8Phase 1 Display Module Fault81Display / Motor Controller communication error (Phase 2 to 3)81-95Display to Motor Controller Module communications errors (see fault code 106).82Phase 2-383Phase 2-384Phase 2-385Phase 2-386Phase 2-387Phase 2-388Phase 2-389Phase 2-39Size setting errorCLr FLtrPump error; the water level has not changed in 6 minutes.COLD flashingCold water supply issue detectedDoor openDoor is detected as not closed for longer than 20 seconds after the program has been…E7:00The initial speed of the motor has been detected as being out of sync.E7:01Motor stall error; the motor control module has been unable to start the motor.E7:02Motor loss of phase; the motor control module has detected a loss of one of the phases of…E7:03Motor over current; the motor control module has detected excessive current.E7:04Motor current sensing circuit is faulty.E7:06The supply voltage level has become too low to power the motor control module.E7:07The motor control module has detected the motor windings are over temperature.E7:08The motor control module has detected that the motor bridge electronics is over…E7:09The motor control module during its self-test routine has detected an error.Err 10Heater NTC has malfunctioned; displayed at the end of the program.Err 105Communication error between the motor control module and the display PCB.Err 12Water level has exceeded the flood protection level.Err 235The door lock has malfunctioned.Err 74Pressure sensor frequency is out of range.Err 75Heater failure; the water failed to reach the selected wash temperature.F1The flood switch has been activated, indicating a leak in the base of the dishwasher, a…F2The motor is not rotating; possible causes include foreign matter jamming the motor…F3The water temperature is greater than 176°F; possible causes include element failed on…F4No temperature increase has been recorded when the element is on; possible causes include…F6Communications baud rate error; the motor control micro has communications set at an…F7Communications time-out error; the motor control micro has crashed and is not responding…F8RAM fault on the electronic controller.HIGH water level flashingMachine is overloaded and cannot agitate.HOT and COLD flashingBoth water supplies have an issueHOT flashingHot water supply issue detectedLid Lock flashingLid is not closed or lid lock mechanism has a problem.no tAPExpected water level not attained within 8 minutes; the machine has detected insufficient…Out OF bALLoad has been detected as not evenly distributed or uneven.RINSE or SPIN flashingMachine has a suds build-up, likely from too much detergent for the amount of soil in the…RINSE or SPIN flashing with SPIN SPEED flashingWash load is out of balance during spin.Sud LOCToo many suds detected in the inner drum.U1Fill fault; the motor has not primed after a given timeU2Tub open fault; the drawer has been forced open during a wash cycle, the drawer…U3Time to fill was too short, indicating water was still in the tubUnfamiliar light pattern with single beep every secondInternal fault detected

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.