mypros+

Fisher & Paykel Refrigerator Error Codes

72 error codes for Fisher & Paykel refrigerator models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any Fisher & Paykel refrigerator error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

26The icemaker motor has timed out; the icemaker gearbox is not returning to the…27The icemaker motor current is high28The icemaker solenoid is drawing more current than expected; either there is a…29The icemaker solenoid is drawing less current than expected; either the wiring…3Filter sensor cold30Display harness fault31Display harness fault32Solenoid Driver 1 has failed; the water dispenser has reverted to Solenoid…33Solenoid Driver 2 has failed34Both Solenoid Drivers 1 and 2 have been detected to have a fault.4Filter sensor hot40Icemaker solenoid transistor 1 short circuit; a transistor on the controller…41Icemaker solenoid transistor 2 short circuit.42The icemaker fill tube nozzle heater current is high (only seen with data…43The icemaker fill tube nozzle heater current is low / element open circuit…44The PC return duct heater current is too high (only seen with data download…45The PC return duct heater current is too low (only seen with data download…49Communication error between control module and inverter.5Defrost sensor cold6Defrost sensor hot7Evaporator inlet sensor cold8Evaporator inlet sensor hot9Evaporator outlet sensor coldEMB-2Embraco inverterEMB-3Embraco inverterEMB-4Embraco inverterEMB-5Embraco inverterF30No display signal received (shorted or broken wire).F31No display signal received (shorted or broken wire) on clock or data line.F32Solenoid Driver 1 & 2 (transistor) has failed, or the solenoid has failed…F33Solenoid Driver 2 (transistor) has failed (display board fault code).F34Both Solenoid Drivers have failed (display board fault code).F40Icemaker solenoid Transistor 1 Short CircuitF41Icemaker display fault (indicated in fault history on LCD Display).INV-1Inverter module error (LED flashes 1 time on inverter).INV-10Inverter module error (LED flashes 10 times on inverter).INV-11Compressor starts and stops.INV-12Compressor starts and stops.INV-13Over current detected.INV-14Communication error between control module and inverter.INV-15AC input voltage is low.INV-16Inverter module error (LED flashes 16 times on inverter).INV-17Motor bridge temperature above 100°C (212°F).INV-18Inverter PCB over temperature.INV-2Inverter module error (LED flashes 2 times on inverter).INV-3Inverter module error (LED flashes 3 times on inverter).INV-4Inverter module error (LED flashes 4 times on inverter).INV-5Inverter module error (LED flashes 5 times on inverter).INV-6Inverter module error (LED flashes 6 times on inverter).INV-7Inverter module error (LED flashes 7 times on inverter).INV-8Compressor cannot start after 6 attempts.INV-9Inverter module error (LED flashes 9 times on inverter).

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started