Speed Queen Washer Error Code E:SP

Serial communication error

Serial communication error - occurs when the master control cannot communicate with the motor control; common causes include blown fuse on motor control board or incorrect wiring to motor control.

First step from the service manual

Check if the fuse is loose or blown on the motor control board; tighten fuse holder and/or replace fuse.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for E:SP.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What E:SP means on a Speed Queen washer

The E:SP error code on a Speed Queen washer indicates a serial communication failure between the master control board and the motor control board. These two boards rely on a continuous data link to coordinate wash cycles, spin speeds, and motor operation. When that communication link is interrupted or lost entirely, the master control throws the E:SP fault and halts operation to prevent uncontrolled motor behavior or mechanical damage.

The most common trigger for this error is a blown or loose fuse located on the motor control board. If this fuse opens due to a power surge or overcurrent event, the motor control board loses power and can no longer respond to signals from the master control. A loose fuse in its holder produces the same result by creating an intermittent or broken circuit. Beyond the fuse, incorrect wiring to the motor control board can also cause this fault. Reversed, disconnected, or improperly seated connectors between the two boards will disrupt the serial communication path.

Diagnosis should begin at the motor control board fuse. Inspect the fuse holder for proper seating, and test the fuse for continuity using a multimeter. A blown fuse requires replacement with a fuse of the correct rating. If the fuse tests good, the next step is to trace and inspect all wiring harness connections between the master control and the motor control board, looking for loose pins, damaged wiring, or connectors that are not fully seated.

Source: manufacturer service documentation.

Common causes of E:SP

  1. 01

    Blown fuse on motor control board

    Part replacement

    A power surge or overcurrent event can blow the fuse on the motor control board, cutting power to that board and breaking communication with the master control. Test the fuse for continuity with a multimeter and replace it if it has opened.

  2. 02

    Loose fuse in fuse holder

    Wiring / connection

    Even without a complete blow, a fuse that is not seated firmly in its holder creates an intermittent or broken circuit that triggers the E:SP fault. Tightening or reseating the fuse in the holder may resolve the error without replacing any parts.

  3. 03

    Incorrect or disconnected wiring to motor control board

    Wiring / connection

    Wiring harness connectors between the master control and motor control that are loose, unseated, or incorrectly routed will disrupt serial communication. Inspect each connector for full seating and check for any damaged or pinched wires.

  4. 04

    Faulty motor control board

    Part replacement

    If the fuse and all wiring connections check out, the motor control board itself may have failed and can no longer maintain communication with the master control. Board replacement is required in this case.

  5. 05

    Failed master control board

    Part replacement

    Less commonly, the master control board may be the source of the communication failure, either unable to send or unable to interpret signals from the motor control. This is typically considered after all other causes are ruled out.

See the test procedure for each cause

Frequently asked questions about E:SP

What does E:SP mean on a Speed Queen washer?
The E:SP code indicates a serial communication error between the master control board and the motor control board. The machine cannot complete a cycle because these two boards are not exchanging data properly. The most common causes are a blown or loose fuse on the motor control board and incorrect or disconnected wiring between the two boards.
Can I fix the E:SP error myself?
Some homeowners with basic electrical knowledge can address this error by locating the motor control board, inspecting the fuse holder, and reseating or replacing the fuse. If the fuse is intact, checking that all wiring connectors are fully seated is the next step. However, if the fault points to a failed control board, professional repair is recommended to ensure correct parts selection and safe installation.
Will resetting the washer clear the E:SP error?
A simple reset is unlikely to permanently clear the E:SP error because it is caused by a hardware problem such as a blown fuse or a wiring fault, not a software glitch. The error will return as soon as the machine attempts to run and the communication failure is detected again. The underlying cause must be repaired before the fault clears for good.
Is it safe to use my Speed Queen washer when E:SP is displayed?
No. The washer has shut itself down specifically because the master control and motor control cannot communicate, which means motor operation cannot be safely managed. Running the machine in this condition risks uncontrolled motor behavior or further damage to the control boards. The issue should be diagnosed and repaired before using the washer again.
How much does it cost to repair the E:SP error on a Speed Queen washer?
If the fix is simply reseating or replacing the fuse on the motor control board, the repair cost is minimal, typically in the range of a few dollars for a replacement fuse plus any service call fee. If a motor control board replacement is needed, parts and labor combined can range from $150 to $400 or more depending on the specific model and local labor rates. A master control board replacement would fall in a similar or higher cost range.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass