Washer
2 documents84 error codes16 service modes
Available documentation
Service Manual
- Service Manual СТИРКА Wm-wd185 pg
Other
- Electrolux EWM2100 ZKG2125 zanussi washing machine guide176 pg
MyPros+ Max
Diagnose your Electrolux ZKG2125.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (84)
CodeMeaning
E00No fault present.E11Water fill fault during main wash phaseE12Water fill fault during drying phase (max fill time 3 min when drum not…E13Water leak detectedE21Drain fault during wash cycleE22Drain fault during drying cycleE23Drain pump triac failure.E24Drain pump triac sensing circuit faultE31Pressure switch circuit faultE32Electronic pressure switch not calibratedE33Mismatch between anti-boiling contact closure and first level pressure switch…E34Mismatch between electronic pressure switch level and anti-boiling pressure…E35Water overflow condition detected.E36Anti-boiling pressure switch sensing circuit fault.E37First level pressure switch sensing circuit fault.E38Pressure chamber blockedE39Overflow protection high-voltage sensing circuit fault.E3AHeater element relay sensing circuit faultE41Door openE42Door closing faultE43Door lock triac failure.E44Door lock sensing circuit fault.E45Door lock triac sensing circuit faultE51Motor triac short circuit.E52No signal from motor tachogenerator.E53Motor triac sensing circuit fault.E54Motor relay contacts stuck/welded.E57Inverter drawing too much current (>15A).E58Motor drawing too much current (>4.5A).E59No tachogenerator signal for more than 3 seconds.View all 84 error codes
E5AInverter heatsink overheating.E5BInput voltage below 175V (ENV06 shown as E5H).E5CInput voltage too high.E5DData transmission error between inverter and main board.E5ECommunication error between main board and inverter.E5FMotor start failure from inverter board.E61Insufficient heating during wash program.E62Overheating during wash cycle (temperature exceeds 88°C for more than 5 min).E66Heater element power relay faultE68Earth leakage detectedE69Heater element failure (blown fuse).E71Wash NTC thermistor faultE72Dryer condenser NTC sensor faultE73Dryer duct NTC sensor faultE74Wash NTC sensor incorrectly positioned.E82Program selector reset position error.E83Selector position identification error.E84Recirculation pump faultE85Recirculation pump triac sensing circuit faultE91Communication error between main board and display board.E92Data transfer mismatch between main board and display board (incompatible…E93Machine configuration errorE94Wash program configuration errorE95Communication error between microprocessor and EEPROM memory.E96Mismatch between hardware version and configuration setting.E97Mismatch between program selector position and program configuration.E98Communication error between main board and inverter (or microprocessor and…E9FCommunication error between main board and external devices.EA1Drum positioning system (DSP) fault.EA6DSP door opening fault.EB1Mains power supply frequency out of acceptable range.EB2Mains supply voltage too high.EB3Mains supply voltage too low.EBEMismatch between safety relay and sensing circuit on main board.EBFSafety system sensing circuit faultEC1Solenoid valve blocked but flow meter still detecting water flow.EC2Water turbidity sensor signal out of range.EC3Weight sensor signal out of range or no signal.Ed1Communication error between WD board and main board.Ed2Dryer heater element relay 1 fault.Ed3Dryer heater element relay 2 fault.Ed4Power switching relay fault between wash heater and dryer on WD board.Ed6Communication error between main board and display board (INPUT model).EF1Drain filter cloggedEF2Excessive detergentEF3Aqua control water leak detection system activated.EF4Low water pressureEF5Laundry load unbalanced during final spin.EF6Reset error.EH1Mains power supply frequency out of range (ENV06 platform variant of EB1).EH2Mains voltage too high (ENV06 platform variant of EB2).EH3Mains voltage too low (ENV06 platform variant of EB3).EHEMismatch between safety relay and sensing circuit (ENV06 variant of EBE).EHFSafety system sensing circuit fault
Service modes (16)
- diagnostic_AEG_New_right_selector["1
- diagnostic_AEG_NexXxt["1
- diagnostic_CLUB_DISPLAY["1
- diagnostic_DELTA_no_selector["1
- diagnostic_ENV06_all_models["1
- diagnostic_ENV06_INPUT_model["1
- diagnostic_EWM1000_horizontal_buttons["1
- diagnostic_EWM1000_vertical_buttons["1
- diagnostic_EWM1000plus_selector_combined_with_ON_OFF["1
- diagnostic_EWM1000plus_selector_with_separate_ON_OFF["1
- diagnostic_LCD_no_selector_separate_ON_OFF["1
- diagnostic_LCD_with_selector_separate_ON_OFF["1
- fault_code_deletion_ENV06["1
- fault_code_deletion_EWM1000["1
- quick_fault_code_view_ENV06["Hold START/PAUSE and nearest OPTION button for 2 seconds
- quick_fault_code_view_EWM1000["Hold START/PAUSE and an OPTION button (horizontal layout) or buttons 2 and 3 (vertical layout)…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Electrolux washer models
78,000+ service manuals · 160,000+ error codes · 55+ brands