mypros+
Model reference

GE GNE26GSDCSS

Refrigerator

3 documents110 error codes1 service mode

Available documentation

Tech Sheet

  • Technical Data - GNE26G*D*** Bottom Freezer2 pg
    Covers this model

Service Manual

  • GE Refrigerator Wiring and Service Diagnostic4 pg
    Covers this model

Tech Tip

  • Articulating Mullion Not Engaging1 pg
    Covers this model
MyPros+ Max

Diagnose your GE GNE26GSDCSS.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (110)

View all 110 error codes
0200FZ Defrost Heater timed out0201FF Defrost Heater timed out02025 consecutive FZ extended defrosts02035 consecutive FF extended defrosts0300N/A0301Temperature satisfied > 3 hours (no compressor operation)0302N/A0303FF Temp Exceeds > 50 F0304FZ Temp Exceeds > 25 F0305N/A0306N/A0307N/A0400N/A0401N/A0402N/A0403Mainboard Software Fault0404Mainboard Hardware Fault0500Main board Relay driver is shorted0501Can't reach Target Hot Water Temp0502Flow meter0503Flow meter signal received with no water dispensing0504Paddle switch pressed > 7 minutes0505Hot water tank filling error0506N/A0507N/A0508Check Paddle switch and wiring0509Check Paddle switch and wiring0510Check Hot water T & P switch and wiring0511Check Hot water T&P switch and wiring0512FF IM Thermistor reading out of range0513Ice Box Thermistor reading out of range0514Hot Water Thermistor reading out of range0515Hot Water Thermistor reading out of range0516Door board Hardware fault0517Hot Water tank Fault0518Door board Hardware fault0519Low Flow Rate, Hot Water Disabled0520N/A0521HW Max Fill Time Out Hot water disabled0522HW Max Dispense Time Out Hot water disabled0600FF IM Harvest Extended >10 mins0601FF IM Harvest Extended 3 out of 10 harvests0602FF IM Harvest Not Completed after 30 mins0603FF IM No water supply detected0604FF IM continues to sense bucket full after ice dispense0605FF IM Moldheater not heating0606N/A0650FZ IM Harvest Extended >10 mins0651FZ IM Harvest Extended 3 out of 10 harvests0652FZ IM Harvest Not Completed after 30 mins0653FZ IM No water supply detected0654FZ IM Moldheater not heating0655N/A (placeholder)0700Stuck keys on Dispenser Boards0701Stuck Keys on Internal Temp Board0702Stuck Keys on Deli Pan0703Key Press on Temp Board while Door Closed0704Key Pressed on Deli Pan Board while Door Closed0705Dispenser Board Auto Fill Error0706Dispenser Board Auto Fill Error0707Dispenser Board Error0708Dispenser Board Error0709Check Paddle switch and wiring0710Check Paddle switch and wiring0711Check Hot water T & P switch and wiring0712Check Hot water T&P switch and wiring0713FF Door open for 15 minutes continuously0714FF Door open for 60 mins total in the last 24 hours071550 FF Left Door Openings in the last 24 hours071650 FF Right Door Openings in the last 24 hours0717FZ Door open for 15 minutes continuously0718FZ Door open for 60 mins total in the last 24 hours071950 FZ Door Openings in the last 24 hours0720N/A0721Upper Auto Fill Sensor Error0722Display board error0800RFID board hardware failure / check filter and filter orientation0801RFID board failed to respond to MB0802RFID board not detecting filter tag / check filter and filter orientation0803RFID filter authentication failed / check filter and filter orientation

Service modes (1)

  • Service DiagnosticsPress the 'Water', 'Crushed', and 'Cubed' buttons simultaneously for 3 seconds

Full entry steps, exit procedures, and test sequences are available in Max.