LG LRUV

Air Conditioner

5 documents82 error codes8 service modes

Available documentation

Service Manual

  • Air Conditioner Service Manual424 pg
    Covers this model
  • Air Conditioner System SERVICE MANUAL406 pg
    Covers this model
  • Air Conditioner System SERVICE MANUAL405 pg
    Covers this model
  • Air Conditioner System SERVICE MANUAL404 pg
    Covers this model
  • Air Conditioner Service Manual R410A340 pg
    Covers this model
MyPros+ Max

Diagnose your LG LRUV.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (82)

CodeMeaning
01Indoor unit air temperature sensor open or short circuit02Indoor unit inlet pipe temperature sensor open or short circuit03Communication error between wired remote controller and indoor unit04Drain pump malfunction05Communication error between outdoor unit and indoor unit06Indoor unit outlet pipe temperature sensor open or short circuit07Indoor unit is operated in a different operation mode from the other operated…09Indoor unit EEPROM serial number error100Discharge temperature of Sub1 outdoor unit constant speed compressor 1 too high101Discharge temperature of Sub1 outdoor unit constant speed compressor 2 too high102Discharge temperature of Sub2 outdoor unit constant speed compressor 1 too high…103Discharge temperature of Sub2 outdoor unit constant speed compressor 2 too high…104Communication error between outdoor units105Communication error between Main Outdoor Unit and fan driving control part106Over-current at Main Outdoor Unit fan motor (IPM Fault)107Low voltage of Main Outdoor Unit fan motor108Communication error from Outdoor Unit to fan driving control part109High Pressure switch of Sub1 Outdoor Unit activated110Reverse connection or disconnection of R,S,T Power line of Sub1 Outdoor Unit111Communication error from Main Outdoor Unit to Sub1 Outdoor Unit113Main Outdoor Unit liquid pipe temperature sensor open or short114Main Outdoor Unit excessive cooling inlet temperature sensor open or short115Main Outdoor Unit excessive cooling outlet temperature sensor open or short116Sub1 Outdoor Unit High Pressure sensor open or short117Sub1 Outdoor Unit Low Pressure sensor open or short118Sub1 Outdoor Unit air temperature sensor open or short120Sub1 Outdoor Unit suction temperature sensor open or short121Sub1 Outdoor Unit constant speed compressor 1 discharge temperature sensor open…122Sub1 Outdoor Unit constant speed compressor 2 discharge temperature sensor open…123Sub1 Outdoor Unit heat exchanger sensor (front side) open or short
View all 82 error codes
124Sub1 Outdoor Unit heat exchanger sensor (rear side) open or short125Sub1 Outdoor Unit liquid pipe temperature sensor open or short126Sub1 Outdoor Unit excessive cooling inlet temperature sensor open or short127Sub1 Outdoor Unit excessive cooling outlet temperature sensor open or short128Sub2 Outdoor Unit High Pressure sensor open or short (3 Units)129Sub2 Outdoor Unit Low Pressure sensor open or short (3 Units)130Sub2 Outdoor Unit air temperature sensor open or short (3 Units)132Sub2 Outdoor Unit suction temperature sensor open or short (3 Units)133Sub2 Outdoor Unit constant speed compressor 1 discharge temperature sensor open…134Sub2 Outdoor Unit constant speed compressor 2 discharge temperature sensor open…135Sub2 Outdoor Unit heat exchanger temperature sensor (front side) open or short…136Sub2 Outdoor Unit heat exchanger temperature sensor (rear side) open or short…137Sub2 Outdoor Unit liquid pipe temperature sensor open or short (3 Units)138Sub2 Outdoor Unit excessive cooling inlet temperature sensor open or short (3…139Sub2 Outdoor Unit excessive cooling outlet temperature sensor open or short (3…140Sub2 Outdoor Unit High Pressure sensor open or short (3 Units)141Reverse connection or disconnection of R,S,T Power line of Sub2 Outdoor Unit142Communication error between outdoor units143Compressor off by excessive increase of Sub1 Outdoor Unit High Pressure144Compressor off by excessive reduction of Sub1 Outdoor Unit Low Pressure145Compressor off by excessive increase of Sub2 Outdoor Unit High Pressure (3…146Compressor off by excessive reduction of Sub2 Outdoor Unit Low Pressure (3…147Input voltage of Sub1 Outdoor Unit is more than 487V or less than 270V148Outdoor voltage sensor of Sub1 Outdoor Unit open or short149Input voltage of Sub2 Outdoor Unit is more than 487V or less than 270V150Outdoor voltage sensor of Sub2 Outdoor Unit open or short151Failure of operation mode conversion21DC peak22Excess of limited current of Main Outdoor Unit inverter compressor23DC link voltage not charged after starting relay turn on for inverter…24High Pressure Switch of Main Outdoor Unit activated, suspending compressor25Input voltage is out of tolerance of rating voltage (more than 487V or less…32Discharge temperature of Main Outdoor Unit inverter compressor too high33Discharge temperature of Main Outdoor Unit constant speed compressor too high34Compressor off by excessive increase of Main Outdoor Unit high pressure35Compressor off by excessive reduction of Main Outdoor Unit low pressure40Current detect (CT) sensor of Main Outdoor Unit inverter compressor open or…41Discharge temperature sensor of Main Outdoor Unit inverter compressor open or…42Outdoor low pressure sensor of Main Outdoor Unit open or short43Outdoor high pressure sensor of Main Outdoor Unit open or short44Outdoor air sensor of Main Outdoor Unit open or short45Heat exchanger sensor of Main Outdoor Unit (front side) open or short46Suction temperature sensor of Main Outdoor Unit open or short47Discharge temperature sensor of the constant speed compressor of Main Outdoor…48Heat exchanger sensor of Main Outdoor Unit (rear side) open or short51Excessive connection of indoor units compared to capacity of outdoor unit52Communication error from inverter control part to Main Outdoor Unit control part53Communication error from indoor unit to Main Outdoor Unit control part54Reverse connection or disconnection of R,S,T power line of Main Outdoor Unit57Communication error from Main control part to inverter control part62Excessive temperature of inverter control part radiation panel (heatsink)65Fan temperature sensor open or short

Service modes (8)

  • auto_addressing["Ensure all indoor and outdoor units are powered on","Press the red button on Main PCB for 6…
  • forced_operation["Press the forced operation button once to start operation"]
  • forced_operation_indoor["Press the Forced Operation Button on the indoor unit.","Unit determines operation mode based on…
  • initial_setup["Step 1
  • test_operation["Open the front panel upward (wall-mounted/Art Cool types)","Press the forced operation/power…
  • test_operation_convertible["Press the forced operation switch and hold for approximately 3 seconds.","Unit operates in…
  • test_operation_indoor_wall_mounted["Open the front panel upward.","Press and hold the forced operation (power) button for…
  • test_operation_wall_mounted["Open the front panel upward.","Press the power button and hold for about 3 seconds.","Unit…

Full entry steps, exit procedures, and test sequences are available in Max.