Model reference
LG LRNU18GTLA0
Air Conditioner
2 documents92 error codes7 service modes
Available documentation
Service Manual
- Air Conditioner Service Manual R22280 pg
- Air Conditioner Service Manual R22280 pg
MyPros+ Max
Diagnose your LG LRNU18GTLA0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (92)
CodeMeaning
01Indoor unit room temperature sensor is open or short circuit.02Indoor unit inlet pipe temperature sensor is open or short circuit.03Transmission error between wired remote controller and indoor unit04Drain pump malfunction05Transmission error between outdoor unit and indoor unit06Indoor unit outlet pipe temperature sensor is open or short circuit.07Operation mode between indoor unit and outdoor unit is different (all units…09Indoor unit EEPROM error10Poor fan motor operation100Discharge temperature of constant speed compressor 1 of sub1 outdoor unit101Discharge temperature of constant speed compressor 2 of sub1 outdoor unit102Discharge temperature of constant speed compressor 1 of sub2 outdoor unit103Discharge temperature of constant speed compressor 2 of sub2 outdoor unit104Transmission error from sub1 outdoor unit to main outdoor unit105Transmission error from fan PCB to main PCB106Over-current of fan motor (IPM fault).107Low voltage of fan motor driver.108Transmission error from main PCB to fan PCB109High pressure switch of sub1 outdoor unit operated by high pressure rising.11Transmission error from indoor unit to main PCB of outdoor unit110Reverse connection or omitting connection of R, S, T power of sub1 outdoor unit.111Transmission error from main outdoor unit to sub1 outdoor unit113Liquid pipe temperature sensor of main outdoor unit is open or short.114Subcooling inlet temperature sensor of main outdoor unit is open or short.115Subcooling outlet temperature sensor of main outdoor unit is open or short.116High pressure sensor of sub1 outdoor unit is open or short.117Low pressure sensor of sub1 outdoor unit is open or short.118Air temperature sensor of sub1 outdoor unit is open or short.120Suction temperature sensor of sub1 outdoor unit is open or short.121Discharge temperature sensor of constant speed compressor 1 of sub1 outdoor…View all 92 error codes
122Discharge temperature sensor of constant speed compressor 2 of sub1 outdoor…123Temperature sensor of front-side heat exchanger of sub1 unit is open or short.124Temperature sensor of rear-side heat exchanger of sub1 unit is open or short.125Liquid pipe temperature sensor of sub1 outdoor unit is open or short.126Subcooling inlet temperature sensor of sub1 outdoor unit is open or short.127Subcooling outlet temperature sensor of sub1 outdoor unit is open or short.128High pressure sensor of sub2 outdoor unit is open or short.129Low pressure sensor of sub2 outdoor unit is open or short.130Air temperature sensor of sub2 outdoor unit is open or short.132Suction temperature sensor of sub2 outdoor unit is open or short.133Discharge temperature sensor of constant speed compressor 1 of sub2 outdoor…134Discharge temperature sensor of constant speed compressor 2 of sub2 outdoor…135Temperature sensor of front-side heat exchanger of sub2 unit is open or short.136Temperature sensor of rear-side heat exchanger of sub2 unit is open or short.137Liquid pipe temperature sensor of sub2 outdoor unit is open or short.138Subcooling inlet temperature sensor of sub2 outdoor unit is open or short.139Subcooling outlet temperature sensor of sub2 outdoor unit is open or short.140High pressure switch of sub2 outdoor unit operated by high pressure rising.141Reverse connection or omitting connection of R, S, T power of sub2 outdoor unit.142Transmission error from main outdoor unit to sub2 outdoor unit143High pressure of sub1 outdoor unit144Low pressure of sub1 outdoor unit145High pressure of sub2 outdoor unit146Low pressure of sub2 outdoor unit147Low/high voltage of sub1 outdoor unit148Voltage detection circuit of sub1 outdoor unit is out of order.149Low/high voltage of sub2 outdoor unit150Voltage detection circuit of sub2 outdoor unit is out of order.151Failure of operation mode conversion173Failure of main constant speed compressor operation174Failure of Sub1 constant speed compressor 1 operation175Failure of Sub1 constant speed compressor 2 operation176Failure of Sub2 constant speed compressor 1 operation177Failure of Sub2 constant speed compressor 2 operation178Failure of Sub3 constant speed compressor 1 operation179Failure of Sub3 constant speed compressor 2 operation21DC peak / IPM fault or overcurrent to inverter compressor.22Overcurrent of inverter compressor23Poor voltage charge for driving inverter compressor24High pressure switch of main outdoor unit operated25Low or over voltage32Discharge temperature of main outdoor unit inverter compressor33Discharge temperature of main outdoor unit constant speed compressor34High pressure of main outdoor unit35Low pressure of main outdoor unit40Current sensor of inverter compressor is open or short.41Discharge temperature sensor of inverter compressor is open or short.42Low pressure sensor of main outdoor unit is open or short.43High pressure sensor of main outdoor unit is open or short.44Air temperature sensor of main outdoor unit is open or short.45Temperature sensor of front-side heat exchanger is open or short.46Suction temperature sensor of main outdoor unit is open or short.47Discharge temperature sensor of the constant speed compressor of main outdoor…48Temperature sensor of rear-side heat exchanger is open or short.49Outdoor voltage sensing error51Excessive capacity of indoor units52Transmission error from inverter PCB to main PCB53Transmission error from indoor unit to main PCB of outdoor unit54Reverse connection of R, S, T power of main outdoor unit57Transmission error from main PCB to inverter PCB62Overheat of inverter heatsink65Temperature sensor of fan heatsink is open or short.
Service modes (7)
- auto_addressing1
- data_display_mode1
- forced_operation_cooling_only_modelPress the forced operation button on the indoor unit main body.
- forced_operation_heat_pump_modelPress the forced operation button on the indoor unit main body
- instant_indoor_unit_checking_cooling1. Set DIP switch
- instant_indoor_unit_checking_heating1. Set DIP switches
- test_operation_indoorPress and hold ON/OFF button for 3-5 seconds until buzzer sounds 1 beep.
Full entry steps, exit procedures, and test sequences are available in Max.