What the F13 error code actually means

Your Maytag stacked dryer is detecting that the upper dryer unit is getting too hot, or the temperature sensor in the upper unit has failed and is sending a bad reading. This is a safety alert that prevents the dryer from running in a potentially dangerous condition. You should stop using the dryer until the cause is identified and corrected.

Diagnostic procedure

The full F13 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F13 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of F13

Ranked by how often they cause this code
  1. 1Blocked or restricted exhaust vent
  2. 2Failed or shorted upper thermistor
  3. 3Faulty blower or restricted airflow inside the cabinet
  4. 4Wiring fault in the thermistor circuit
  5. 5Control board malfunction

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about F13

What does F13 mean on a Maytag dryer?
F13 on a Maytag stack dryer means the control board has detected that the upper thermistor is reporting a temperature above the safe operating limit. This can indicate a real overheating condition caused by restricted airflow, or it can indicate a failed thermistor sending a false signal. The dryer will stop operating to prevent heat damage or a fire hazard. The upper unit's venting and thermistor circuit should be inspected before restarting the dryer.
Is the F13 error on a Maytag dryer a safety concern?
Yes, F13 should be taken seriously because it indicates either a genuine overheating event or a sensor failure that prevents proper temperature monitoring. Both scenarios are safety concerns: actual overheating can lead to component damage or fire, and a failed sensor means the dryer may be running without reliable temperature control. Do not continue operating the dryer until the cause has been identified and repaired.
How much does it cost to repair an F13 error on a Maytag dryer?
Repair costs vary depending on the cause. Cleaning a blocked vent is typically a low-cost fix you may be able to do yourself. Replacing the upper thermistor generally involves a modest parts cost, typically in the range of $15 to $50 for the sensor, plus labor if you hire a technician. A control board replacement is the most expensive scenario, with parts alone often ranging from $100 to $250 or more depending on the model.
Can I reset the F13 code and keep using my Maytag dryer?
You can attempt a reset by unplugging the dryer for a few minutes and restoring power, but if the underlying cause is not corrected the code will return. If the code is caused by an actual airflow restriction or overheating condition, continuing to run the dryer without addressing the problem is a fire risk. A reset is only appropriate as a temporary step while you diagnose the root cause.
How do I fix the F13 error on a Maytag stack dryer?
Start by cleaning the lint screen and inspecting the exhaust duct for the upper unit to rule out airflow restriction. If venting is clear, test the upper thermistor with a multimeter to check for a short circuit or resistance reading that falls outside the normal operating range. Also inspect the wiring harness connecting the thermistor to the control board for any damage or corrosion at the connectors. If the thermistor or wiring checks out, a control board fault or blower issue may require further diagnosis.