mypros+
Model reference

GE GFE28

Refrigerator

16 documents119 error codes26 service modes

Available documentation

Service Manual

  • Appliance Service Diagnostic Functions and Specifications2 pg
    Covers this model
  • GE Refrigerator Minimanual 31 518942 pg
    Covers this model
  • GE Mini Manual4 pg
    Covers this model
  • Mini Manual 362564 pg
    Covers this model
  • 2012 Profile and GE French Door Refrigerators Service Manual91 pg
    Covers this model

Tech Sheet

  • Technical Data - Service Diagnostic Functions2 pg
    Covers this model
  • GFE29HSDA Tech Sheet4 pg
    Covers this model

Bulletin

  • Service Bulletin REF12-17 - French Door Refrigerators - Icemaker Water Valve Chattering2 pg
    Covers this model
  • Freezer Icemaker Not Making Ice1 pg
    Covers this model
  • GE French Door Refrigerator Service Bulletin Freezer Icemaker Not Making Ice REF07 161 pg
    Covers this model
  • GE Refrigerator Service Bulletin Moisture On Fresh Food Evaporator Fan REF06 161 pg
    Covers this model
  • Service Bulletin - Moisture On Refrigerator Evaporator Fan / Noisy Fan1 pg
    Covers this model

Tech Tip

  • Articulating Mullion Not Engaging1 pg
    Covers this model

Other

  • 16 RE 01 En Fr4 pg
    Covers this model
  • 31 51901 GE4 pg
    Covers this model
  • 31 519324 pg
    Covers this model
MyPros+ Max

Diagnose your GE GFE28.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (119)

View all 119 error codes
0200FZ Defrost Heater timed out0201FF Defrost Heater timed out02025 consecutive FZ extended defrosts02035 consecutive FF extended defrosts0300Temperature satisfied > 3 hours (no compressor operation)0301Temperature satisfied > 3 hours (no compressor operation)0302FF Temp Exceeds > 55°F0303FZ Temp Exceeds > 25°F0304FZ Temp Exceeds > 25 F0305N/A0306N/A0307N/A0400Mainboard Software Fault0401Can't reach Target Hot Water Temp0402Flow meter0403Flow meter signal received with no water dispensing0404Flow meter0500Paddle switch pressed > 7 minutes0501Hot water tank not full while heating0502Check Paddle switch and wiring0503Check Paddle switch and wiring0504Check Paddle switch and wiring0505Check Paddle switch and wiring0506Check Hot water T&P switch and wiring0507Check Hot water T&P switch and wiring0508FF IM Thermistor reading out of range0509Ice Box Thermistor reading out of range0510Hot Water Thermistor reading out of range0511Hot Water Thermistor reading out of range0512Door board Hardware fault0513Hot Water tank Fault0514Door board Hardware fault0515Low Flow Rate, Hot Water Disabled0516HW Max Dispense Time Out Hot water disabled0517HW Max Fill Time Out Hot water disabled0518HW Max Dispense Time Out Hot water disabled0519HW Max Purge Time Out Hot water disabled0520Feature Board communication error0521Dispense nozzle movement error0522Brew Module not detected during brew0523High flow during brewing0524Low flow during brewing0525Feature board hardware fault0526Air valves over current error0527Air pump over current error0570Feature Board hardware fault0571Feature Board hardware fault0572Feature Board hardware fault0573Feature Board hardware fault0600FF IM failure (N/A0601FF IM Harvest Extended > 10 mins0602FF IM Harvest Extended 3 out of 10 harvests0603FF IM Harvest Not Completed after 30 mins0604FF IM No water supply detected0605FF IM continues to sense bucket full after ice dispense0606FF IM Moldheater not heating0650FZ IM Harvest Extended >10 mins0651FZ IM Harvest Extended > 10 mins0652FZ IM Harvest Extended 3 out of 10 harvests0653FZ IM Harvest Not Completed after 30 mins0654FZ IM No water supply detected0655FZ IM Moldheater not heating0700Stuck keys on Dispenser Boards0701Stuck Keys on Internal Temp Board0702Stuck Keys on Deli Pan0703Key Press on Temp Board while Door Closed0704Key Pressed on Deli Pan Board while Door Closed0705Dispenser Board Auto Fill Error0706Dispenser Board Auto Fill Error0707Dispenser Board Error0708Dispenser Board Error0709Check Paddle switch and wiring0710Check Paddle switch and wiring0711Check Hot water T&P switch and wiring0712Check Hot water T&P switch and wiring0713FF Door open for 15 minutes continuously0714FF Door open for 60 mins total in the last 24 hours0715100 FF Left Door Openings in the last 24 hours0716100 FF Right Door Openings in the last 24 hours0717FZ Door open for 15 minutes continuously0718FZ Door open for 60 mins total in the last 24 hours0719100 FZ Door Openings in the last 24 hours0720N/A0721Upper Auto Fill Sensor Error (Clean sensors)0722Display Board Error0800RFID board hardware failure / check filter and filter orientation0801RFID board failed to respond to MB0802RFID board not detecting filter tag / check filter and filter orientation0803RFID filter authentication failed / check filter and filter orientation

Service modes (26)

  • Auto Fill Sensor Diagnostic (PFE29)1. Wake the screen. 2. Simultaneously press and hold the Water, Cubed, and Precise Fill buttons for…
  • Clear Fault Codes["Enter Service Diagnostics mode","Select test 01 (FZ display 00, FF display 01)"]
  • COM VersionIn Service Diagnostics mode, set FZ display to 00 and FF display to 06, then run test.
  • Dealer Demo Mode (GE/Adora LED Models)Press the Refrigerator and Freezer up arrow buttons simultaneously.
  • Dealer Demo Mode (LCD Models - PFE29)Press Lock Controls and Precise Fill pads simultaneously for 3 seconds
  • Degrees C ModeIn Service Diagnostics mode, set FZ display to 00 and FF display to 07, then run test.
  • Degrees F ModeIn Service Diagnostics mode, set FZ display to 00 and FF display to 08, then run test.
  • Demo Mode["Internal Water Models
  • Dispenser Self-Test Mode["Enter Service Diagnostics mode","Select test 02 (FZ display 00, FF display 02)"]
  • Exit Service ModeIn Service Diagnostics mode, set FZ display to 00 and FF display to 16, then run test.
  • Exits all DefrostIn Service Diagnostics mode, set FZ display to 00 and FF display to 15, then run test.
  • Fault Code Navigation (Cafe Models)["Enter service diagnostics (test 00 00)","Press up and down arrows to see multiple faults (3…
  • Fault Code Navigation (GE/Adora/Profile Models)["Enter service diagnostics (test 00 00)","Error code displayed first (xx xx), then how many times…
  • Fault Code Navigation (Profile Models with Keurig)["Enter service diagnostics (test 00 00)","Error code displayed first (xx xx), then how many times…
  • Fault Code Viewing (Test 00 00)["Enter Service Diagnostics (see above), test 00 00 is the default.","Cafe Models
  • Force FF and FZ DefrostIn Service Diagnostics mode, set FZ display to 00 and FF display to 14, then run test.
  • Sabbath Mode["Internal Water Models
  • Sabbath Mode (Capacitive Touch Models)["Simultaneously press Lock and Light for 3 seconds"]
  • Sabbath Mode (GE/Adora LED Models)Press and hold the Dispenser Light and Lock Controls buttons for 3 seconds.
  • Sabbath Mode (Internal Water Models)["Simultaneously press Door Alarm and Icemaker buttons for 3 seconds"]
  • Sabbath Mode (LCD Models - PFE29)Press and hold simultaneously the Lock Controls and Light buttons for 3 seconds.
  • Sabbath Mode (LCD Models)["Simultaneously press Lock Controls and Light for 3 seconds"]
  • Sabbath Mode (Single Serve Capacitive Touch Models)["Simultaneously press Door Alarm and Light for 3 seconds"]
  • Service Diagnostic ModePress the Water, Crushed, and Cubed buttons simultaneously for 3 seconds. The display will show…
  • Service Diagnostics["Capacitive Touch (Autofill Units)
  • Show Fault Codes["Enter Service Diagnostics mode","Select test 00 (FZ display 00, FF display 00)"]

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass