Service Manual

  • Smartdrive® Washing Machine50 pg
    Covers this model
  • SMARTDRIVE® WASHING MACHINE Diagnostic Guide50 pg
    Covers this model

Tech Sheet

  • Diagnostics Smart Drive Phases 1 650 pg
    Covers this model
MyPros+ Max

Diagnose your Fisher & Paykel 517769.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (94)

View all 94 error codes
20Phase 122Phase 123Phase 1230Phase 6: EEPROM value out of range231Phase 6: MW GW link error232Phase 6 IW: Communications timeout 5 seconds233Phase 6: EEPROM read error234Phase 6235Phase 6: Lid lock short circuit236Phase 6: Incompatible EEPROM version237Phase 6: Temperature sensor error238Phase 6: Lid lock fail in-line test (1)239Phase 6: Lid lock fail in-line test (2)240Phase 6: Hall (RPS) out of order241Phase 6: Function time out242Phase 6243Phase 6: Stepper test failure25Phase 5 IW: LCD initialization error28Phase 129Phase 13Motor Control Module memory error (all phases).30Phase 132Phase 133Phase 134Phase 1: Brake resistor circuit fault35Phase 136Water leak fault37Pump blocked error38Pressure sensor fault39Pressure tube fault4Phase 140Bowl dis-engage fault41Temperature sensor (thermistor) measuring above 110°C, likely short circuit in…42Phase 1: Rotor fault43Out of balance switch fault44Phase 2-645Phase 5: Display memory check fault46Phase 5 IW: Display EEPROM check error47Phase 2-3: Bowl dis-engage fault48Phase 2-6: Both hot and cold water valves faulty49Phase 2-6: Cold water valve faulty5Phase 150Phase 2-6: Hot water valve faulty51Phase 5-6 Eco: Diverter valve fault52Phase 5-6 Eco: Diverter top-up fault53Phase 2-6: Rotor Position Sensor step fail54Phase 2-6: Motor/Motor Control Module step fail55Phase 3-6: System step fail56Phase 4-6: Bowl check no valid fault57Phase 4-6: Brown out during Display EEPROM write58Phase 4-5: Pressure transducer at maximum adjustment fault59Phase 4-5: ID out of range fault6Phase 160Phase 4-6: Motor Control Module memory check fault61Phase 4: Brown out during Motor Control Module EEPROM write62Phase 5: Pump over current63Phase 5: Pump comms error64Phase 5-6: Pressure transducer error65Phase 5-6: Pressure transducer error66Phase 6: Pressure transducer error7Display Module memory fault (all phases).8Phase 181Phase 2-39Size switch setting on Display Module does not match that stored in memory (all…

Service modes (27)

  • Data Display Mode (IW models)From diagnostic mode, push the LIFECYCLES button again (SPECIAL button on Phase 5)
  • Data Download["Enter Diagnostic Mode.","Press START/PAUSE.","GW/MW/LW
  • Diagnostic Mode (GW/MW/LW models)1
  • Diagnostic Mode (IW models)1
  • Drain Pump Test (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only
  • Drain Pump Test (IW models)["Enter Diagnostic Mode.","Press the FABRIC CARE button to activate pump."]
  • Fault Code Display (GW/MW/LW)1
  • Hot Bowl Flag Reset (IW)["Enter Control Option mode.","Push ADJUST button (Phase 5
  • Lid Switch / Out of Balance Switch Test (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only: press the ADVANCE button once.","Phases 4-5 only: press…
  • Lid Switch Test (IW Phase 5)["Enter Diagnostic Mode.","Bring up the Machine Status display.","Open and close lid to change…
  • Option Adjustment Mode1
  • Option Adjustment Mode (GW/MW/LW Phases 1-5)["With SmartDrive powered on at the wall and with the LEDs off.","Press and hold the START/PAUSE…
  • Option Adjustment Mode (IW Phase 5)1
  • Option Adjustment Mode (IW Phase 6)1
  • Option Adjustment Mode (Phase 5 IW)["Turn the machine on.","Press and hold the OPTIONS button for 4 seconds.","The Adjust Options Menu…
  • Option Adjustment Mode (Phase 6 IW)["Turn the machine on.","Press and hold the OPTIONS UP button for 3 seconds until a beep is…
  • Recycle Feature Toggle (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only
  • Recycle Feature Toggle (IW)["In Control Options mode (same as RESTART setting).","Push ADJUST button (Phase 5
  • Restart Feature Toggle (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only
  • Restart Feature Toggle (IW)["Enter Diagnostic Mode.","Press OPTIONS button to bring up CONTROL OPTION screen.","Push ADJUST…
  • Size Setting Mode (GW/MW/LW Phase 4-6)1
  • Size Setting Mode (GW/MW/LW Phases 4-6)1
  • Size Setting Mode (IW models)1. Turn power on at the power point and off at the console. 2. Press and hold the FABRIC CARE…
  • Size Setting Mode (IW Phase 5)["Turn the power on at the power point and off at the console.","Press and hold the FABRIC CARE…
  • Size Setting Mode (IW Phase 6)["Turn the power on at the power point and off at the console.","Press and hold the FABRIC CARE…
  • Water Valve Test (GW/MW/LW)["Enter Diagnostic Mode.","Press WASH TEMP UP to turn hot water valve on (Hot LED on when…
  • Water Valve Test (IW models)["Enter Diagnostic Mode.","Press HOW DIRTY down button to turn cold water valve on.","Press HOW…