Model reference

Fisher & Paykel GW-L10

Washer

6 documents94 error codes26 service modes

Available documentation

Service Manual

  • ELECTRONIC WASHING MACHINE GWL11 / IWL12 PHASE 6 Series 11 / 12 120v 60Hz Supplementary manual47 pg
    Covers this model
  • ELECTRONIC WASHING MACHINE PHASE 6 Series 11 120v 60 Hz41 pg
    Covers this model
  • ELECTRONIC WASHING MACHINE PHASE 6 Series 11 120v 60 Hz41 pg
    Covers this model

Quick Reference

  • SmartDrive Diagnosis Guide - Read Fault Codes2 pg
    Covers this model

Other

  • FisherPaykelSvcManual47 pg
    Covers this model
  • 517766B47 pg
    Covers this model
MyPros+ Max

Diagnose your Fisher & Paykel GW-L10.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (94)

View all 94 error codes
20Phase 1 Display / Motor Controller out of Sequence.22Phase 1 Display / Motor Controller out of Sequence.23Phase 1 Display / Motor Controller out of Sequence.230Phase 6 EEPROM Value out of Range231Phase 6 MW GW Link Error232Phase 6 COMMS Timeout 5 Sec233Phase 6 EEPROM Read Error234Phase 6 Lid Lock Open Circuit235Phase 6 Lid Lock Short Circuit236Phase 6 Incompatible EEPROM Version237Phase 6 Temperature Sensor Error238Phase 6 Lid Lock Fail In-Line Test (1)239Phase 6 Lid Lock Fail In-Line Test (2)240Phase 6 Hall Out Of Order / RPS Fault241Phase 6 Function Time Out242Phase 6 OOB Hit Greater than Max for 5 Sec243Phase 6 Stepper Test Failure25Phase 5 IW LCD Initialisation Error28Phase 1 Display / Motor Controller out of Sequence.29Phase 1 Display / Motor Controller out of Sequence.3The Motor Controller Module has found a memory error.30Phase 1 Display / Motor Controller out of Sequence.32Phase 1 Pump Circuit Error33Phase 1 Water Valve Fault34Phase 1 Brake Resistor Fault35Phase 1 MC Reset Error36Water Leak Fault37Pump Blocked Error38Pressure Sensor Fault39Pressure Tube Fault4Phase 1 Communications Fault40Bowl Dis-engage Fault41Temperature Sensor Fault (Thermistor)42Phase 1 Rotor Fault43OOB Switch Fault44Water in Tub during Spin45Phase 5 Display Memory Check Fault46Phase 5 IW Display EEPROM Check47Phase 2 and 3 Basket Dis-engage Fault48Hot and Cold Valve Faulty49Cold Valve Faulty (proportional)5Phase 1 Communications Fault50Hot Valve Faulty (digital)51Phase 5 and 6 Eco Diverter Valve Fault52Phase 5 and 6 Eco Diverter Top-up Fault53Rotor Position Sensor Step Fail54Motor/Motor Controller Module Step Fail55Phase 3 to 6 System Step Fail56Phase 4 to 6 Basket Check No Valid Fault57Phase 4 to 6 Brown Out During Display EEPROM Write Fault58Phase 4 to 5 Pressure Transducer at Maximum Adjustment59Phase 4 to 5 ID Out of Range Fault6The Motor Controller module (Display Module for Phase 1) has received an…60Phase 4 to 6 Motor Control Memory Check Fault61Phase 4 Brown Out During Motor Controller EEPROM Write Fault62Phase 5 Pump Over Current63Phase 5 Pump Comms Error64Phase 5 and 6 Pressure Transducer (Ptx) error65Phase 5 and 6 Pressure Transducer (Ptx) error66Pressure Transducer Error7The Display module has found a memory fault.8Phase 1 Display Module Fault81Phase 2 to 3 Display/Motor Controller communication error (see fault code 106).9Size Switch Error

Service modes (26)

  • Data Display Mode - IW1
  • demonstrationPress and hold the ADVANCE button, then press the POWER button.
  • Demonstration Mode1
  • Demonstration Mode - GW1
  • Demonstration Mode - IW1
  • diagnostic1
  • Diagnostic Mode1
  • Diagnostic Mode - GW (Ecosmart)1
  • Diagnostic Mode - IW (Intuitive)1
  • Drain Pump Test - GW1
  • Drain Pump Test - IW1
  • Hot Tub Flag Clear - GW1
  • Hot Tub Flag Clear - IW1
  • Pump Pulse Disable - GW1
  • Pump Pulse Setting (within Size Setting Mode)1
  • Recycle Feature - GW1
  • Recycle Feature - IW1
  • Restart Feature Setting - GW1
  • Restart Feature Setting - IW1
  • Restart/Recycle Setting Mode1. Enter Diagnostic Mode (power on at wall, off at console; press and hold WASH TEMPERATURE DOWN…
  • Size Setting Mode1
  • Size Setting Mode - GW1
  • Size Setting Mode - IW1
  • size_setting1. Turn power on at the power point and off at the console. 2. Press and hold the TEMPERATURE UP…
  • Water Valve Test - GW1
  • Water Valve Test - IW1

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax