Error codes (94)
CodeMeaning
1Motor Controller Module (Display Module for Phase 1) has encountered an error…10Temperature Sensor (Thermistor) Error104Phase 2 to 6 communication error (see fault code 106).105Phase 2 to 6 Comms Error Time out106Phase 2 to 3 (and Phase 6 IW) Display to Motor Controller Communications Error.107Phase 2 to 6 Motor Controller Module Reset Error108Phase 6 IW Comms CRC Error (see fault code 106).11Pressure Sensor Fault12Flood Protection Error127Phase 5 Machine Set up Error13Phase 1 Pump Fault130Single Rotor Position Sensor Error131Repetitive Rotor Position Sensor Error132Phase 1 to 4 Single Current Trip133Phase 1 to 4 Repetitive Current Trip134Phase 4 Single Current Trip & Rotor Position Error136Motor Stall14Phase 1 Pump Connection Fault144Phase 1 Motor Controller Software Trap15Phase 1 Display Module Fault160Basket Engaged161Phase 2 to 6 Hardware/EEPROM Supply Mismatch162Phase 3 to 5 Brake Deceleration Time-out Fault163Phase 4 to 6 Valve Reset Pin Connect Fault164Phase 4 to 5 Brake Function Time-out Fault17Phase 1 Display / Motor Controller out of Sequence.18Phase 1 Display / Motor Controller out of Sequence.19Phase 1 Display / Motor Controller out of Sequence.192Phase 4 to 5 Motor PWM Reset Pin Connect Fault2An error has been encountered when trying to read the pressure sensor.View all 94 error codes
20Phase 1 Display / Motor Controller out of Sequence.22Phase 1 Display / Motor Controller out of Sequence.23Phase 1 Display / Motor Controller out of Sequence.230Phase 6 EEPROM Value out of Range231Phase 6 MW GW Link Error232Phase 6 COMMS Timeout 5 Sec233Phase 6 EEPROM Read Error234Phase 6 Lid Lock Open Circuit235Phase 6 Lid Lock Short Circuit236Phase 6 Incompatible EEPROM Version237Phase 6 Temperature Sensor Error238Phase 6 Lid Lock Fail In-Line Test (1)239Phase 6 Lid Lock Fail In-Line Test (2)240Phase 6 Hall Out Of Order / RPS Fault241Phase 6 Function Time Out242Phase 6 OOB Hit Greater than Max for 5 Sec243Phase 6 Stepper Test Failure25Phase 5 IW LCD Initialisation Error28Phase 1 Display / Motor Controller out of Sequence.29Phase 1 Display / Motor Controller out of Sequence.3The Motor Controller Module has found a memory error.30Phase 1 Display / Motor Controller out of Sequence.32Phase 1 Pump Circuit Error33Phase 1 Water Valve Fault34Phase 1 Brake Resistor Fault35Phase 1 MC Reset Error36Water Leak Fault37Pump Blocked Error38Pressure Sensor Fault39Pressure Tube Fault4Phase 1 Communications Fault40Bowl Dis-engage Fault41Temperature Sensor Fault (Thermistor)42Phase 1 Rotor Fault43OOB Switch Fault44Water in Tub during Spin45Phase 5 Display Memory Check Fault46Phase 5 IW Display EEPROM Check47Phase 2 and 3 Basket Dis-engage Fault48Hot and Cold Valve Faulty49Cold Valve Faulty (proportional)5Phase 1 Communications Fault50Hot Valve Faulty (digital)51Phase 5 and 6 Eco Diverter Valve Fault52Phase 5 and 6 Eco Diverter Top-up Fault53Rotor Position Sensor Step Fail54Motor/Motor Controller Module Step Fail55Phase 3 to 6 System Step Fail56Phase 4 to 6 Basket Check No Valid Fault57Phase 4 to 6 Brown Out During Display EEPROM Write Fault58Phase 4 to 5 Pressure Transducer at Maximum Adjustment59Phase 4 to 5 ID Out of Range Fault6The Motor Controller module (Display Module for Phase 1) has received an…60Phase 4 to 6 Motor Control Memory Check Fault61Phase 4 Brown Out During Motor Controller EEPROM Write Fault62Phase 5 Pump Over Current63Phase 5 Pump Comms Error64Phase 5 and 6 Pressure Transducer (Ptx) error65Phase 5 and 6 Pressure Transducer (Ptx) error66Pressure Transducer Error7The Display module has found a memory fault.8Phase 1 Display Module Fault81Phase 2 to 3 Display/Motor Controller communication error (see fault code 106).9Size Switch Error
Service modes (8)
- demonstrationPress and hold the ADVANCE button, then press the POWER button.
- Demonstration Mode1
- diagnostic1
- Diagnostic Mode1
- Pump Pulse Setting (within Size Setting Mode)1
- Restart/Recycle Setting Mode1. Enter Diagnostic Mode (power on at wall, off at console; press and hold WASH TEMPERATURE DOWN…
- Size Setting Mode1
- size_setting1. Turn power on at the power point and off at the console. 2. Press and hold the TEMPERATURE UP…