Model reference
Fisher & Paykel IWL12
Washer
13 documents110 error codes52 service modes
Available documentation
Service Manual
- Smart Drive Electronic Washing Machine Model GWL11 IWL12 51775319 pg
- ELECTRONIC WASHING MACHINE GWL11 / IWL12 PHASE 6 Series 11 / 12 120v 60Hz47 pg
- ELECTRONIC WASHING MACHINE GWL11 / IWL12 PHASE 6 Series 11 / 12 120v 60Hz Supplementary manual47 pg
- Smart Drive Electronic Washing Machine25 pg
- Smartdrive Washing Machine 51776950 pg
- Smartdrive® Washing Machine50 pg
- SMARTDRIVE® WASHING MACHINE Diagnostic Guide50 pg
Tech Sheet
- Service Summary GWL11 / IWL124 pg
- Diagnostics Smart Drive Phases 1 650 pg
Bulletin
- Service Bulletin - Unable to Fit Motor Control Module 420094USP1 pg
- Smart Drive Electronic Module Summary Phases 3 - 6 USA5 pg
- Smart Drive New Model Introduction – Phase 6 Series 12 - NZ, AUS, ROW4 pg
Installation Guide
- IWL12 Clothes Washer Installation Instructions and User Guide80 pg
MyPros+ Max
Diagnose your Fisher & Paykel IWL12.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (110)
CodeMeaning
#130Rotor Position Sensor error#131Rotor Position Sensor error#132High motor current#133High motor current#136Motor stall#37Pump blocked error#39Pressure tube fault#40Basket disengage fault#43Out of balance switch fault#47Lid lock fault.#48Hot and/or cold water valve faulty.#49Hot and/or cold water valve faulty.#50Hot and/or cold water valve faulty.#51Diverter valve fault#52Diverter valve fault#9Machine size setting does not match that stored in memory.1Motor Controller Module (Display for Phase 1) has encountered an error when…10Temperature sensor (thermistor) may be open circuit or ambient temperature is…104Phase 2-6105Comms error timeout106Display to Motor Controller communications error.107Motor Controller module reset error108Comms CRC error (Phase 6 IW Display only).11While measuring water level, the Motor Controller detected a negative pressure…12Flood protection error127Machine setup error13Pump fault130Single rotor position sensor error131Repetitive rotor position sensor error132Single current tripView all 110 error codes
133Repetitive current trip134Single current trip and rotor position error simultaneously (Phase 4).136Motor stall14Pump connection fault144Motor Controller software trap15Display Module has read an incorrect voltage on the pump circuit (Phase 1).160Basket engaged161Hardware/EEPROM supply mismatch162Brake deceleration timeout fault163Valve reset pin connect fault164Brake function timeout fault17Phase 118Phase 119Phase 1192Motor PMW reset pin connect fault2An error has been encountered when trying to read the pressure sensor.20Phase 122Phase 123Phase 1230EEPROM value out of range231MW GW link error232COMMS timeout 5 seconds233EEPROM read error234Lid lock open circuit235Lid lock short circuit236Incompatible EEPROM version237Temperature sensor error238Lid lock fail in-line test (1)239Lid lock fail in-line test (2)240Hall out of order / RPS fault241Function timeout242OOB hit greater than max for 5 seconds243Stepper test failure25LCD Initialisation Error28Phase 129Phase 13Motor Controller Module has found a memory error.30Phase 132Pump circuit error33Water valve fault34Brake resistor fault35MC Reset Error36Water leak fault37Pump blocked error38Pressure sensor fault39Pressure tube fault4The Motor Controller has had difficulty communicating with the Display Module…40Bowl disengage fault41Temperature sensor fault (thermistor)42Rotor fault43OOB switch fault44Water in tub during spin45Display memory check fault46Display EEPROM check47Basket disengage fault48Hot and cold valve faulty49Cold valve (proportional) faulty5The Display Module has had difficulty communicating with the Motor Controller…50Hot valve (digital) faulty51Diverter valve fault52Diverter top-up fault53Rotor Position Sensor step fail54Motor/Motor Controller module step fail55System step fail (Phase 3 to 6).56Basket check no valid fault57Brown out during Display EEPROM write58Pressure transducer at maximum adjustment59ID out of range fault6Motor Controller module (Display for Phase 1) has received an incorrect signal…60Motor Control memory check fault61Brown out during Motor Controller EEPROM write62Pump over current63Pump comms error64Pressure transducer error65Pressure transducer error66Pressure transducer error (Ptx frequency >90 kHz)7Display module has found a memory fault.8Display micro has not been able to start up correctly (Phase 1 only).81Phase 2-39Display size switch setting does not match that stored in memory.
Service modes (52)
- Data Display Mode - IW1
- Data Display Mode (IW models)From diagnostic mode, push the LIFECYCLES button again (SPECIAL button on Phase 5)
- Data Download["Enter Diagnostic Mode.","Press START/PAUSE.","GW/MW/LW
- Demonstration Mode - GWPress and hold the ADVANCE button, then press the POWER button.
- Demonstration Mode - IWPress START/PAUSE and hold down, then press POWER.
- Diagnostic Mode["Turn the power on at the power point and off at the console.","IWL12
- Diagnostic Mode - GW (Ecosmart)1
- Diagnostic Mode - IW (Intuitive)1
- Diagnostic Mode (GW/MW/LW models)1
- Diagnostic Mode (IW models)1
- Drain Pump Test - GW1
- Drain Pump Test - IW1
- Drain Pump Test (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only
- Drain Pump Test (IW models)["Enter Diagnostic Mode.","Press the FABRIC CARE button to activate pump."]
- Drain Pump Test (within Diagnostic Mode)["Enter Diagnostic Mode.","IWL12
- Fault Code Display (GW/MW/LW)1
- Hot Bowl Flag Reset (IW)["Enter Control Option mode.","Push ADJUST button (Phase 5
- Hot Tub Flag Clear - GW1
- Hot Tub Flag Clear - IW1
- Lid Switch / Out of Balance Switch Test (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only: press the ADVANCE button once.","Phases 4-5 only: press…
- Lid Switch Test (IW Phase 5)["Enter Diagnostic Mode.","Bring up the Machine Status display.","Open and close lid to change…
- Machine Size Setting["Turn the power on at the power point and off at the console.","IWL12
- Option Adjustment Mode1
- Option Adjustment Mode (GW/MW/LW Phases 1-5)["With SmartDrive powered on at the wall and with the LEDs off.","Press and hold the START/PAUSE…
- Option Adjustment Mode (IW Phase 5)1
- Option Adjustment Mode (IW Phase 6)1
- Option Adjustment Mode (Phase 5 IW)["Turn the machine on.","Press and hold the OPTIONS button for 4 seconds.","The Adjust Options Menu…
- Option Adjustment Mode (Phase 6 IW)["Turn the machine on.","Press and hold the OPTIONS UP button for 3 seconds until a beep is…
- Out Of Balance Switch Test (within Diagnostic Mode)["Enter Diagnostic Mode.","IWL12
- Pump Pulse Disable - GW1
- Recycle Feature - GW1
- Recycle Feature - IW1
- Recycle Feature Toggle (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only
- Recycle Feature Toggle (IW)["In Control Options mode (same as RESTART setting).","Push ADJUST button (Phase 5
- Restart Feature - GW1. Enter Diagnostics Mode (power off at machine, on at wall; press and hold Wash Temp Down then…
- Restart Feature - IW1
- Restart Feature Setting - GW1
- Restart Feature Setting - IW1
- Restart Feature Toggle (GW/MW/LW)["Enter Diagnostic Mode.","Phase 3 only
- Restart Feature Toggle (IW)["Enter Diagnostic Mode.","Press OPTIONS button to bring up CONTROL OPTION screen.","Push ADJUST…
- Size Setting Mode - GW1
- Size Setting Mode - IW1
- Size Setting Mode (GW/MW/LW Phase 4-6)1
- Size Setting Mode (GW/MW/LW Phases 4-6)1
- Size Setting Mode (IW models)1. Turn power on at the power point and off at the console. 2. Press and hold the FABRIC CARE…
- Size Setting Mode (IW Phase 5)["Turn the power on at the power point and off at the console.","Press and hold the FABRIC CARE…
- Size Setting Mode (IW Phase 6)["Turn the power on at the power point and off at the console.","Press and hold the FABRIC CARE…
- Water Valve Test - GW1
- Water Valve Test - IW1
- Water Valve Test (GW/MW/LW)["Enter Diagnostic Mode.","Press WASH TEMP UP to turn hot water valve on (Hot LED on when…
- Water Valve Test (IW models)["Enter Diagnostic Mode.","Press HOW DIRTY down button to turn cold water valve on.","Press HOW…
- Water Valve Test (within Diagnostic Mode)["Enter Diagnostic Mode.","IWL12
Full entry steps, exit procedures, and test sequences are available in Max.
Related Fisher & Paykel washer models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax